Table 1
Diagnostic Codes Table    
J1939 Code and Description    Conditions which Generate this Code    System Response    
168-3
Battery Potential / Power Input #1 : Voltage Above Normal     Electrical System Voltage : Voltage Above Normal     The code is logged.    
168-4
Battery Potential / Power Input #1 : Voltage Below Normal     Electrical System Voltage : Voltage Below Normal     The code is logged.    The engine ECM requires the keyswitch to be in the ON position in order to maintain communications with Caterpillar Electronic Technician (ET).
Illustration 1 g03321350
Location of the J1/P1 and the J2/P2 ECM connectors (typical engine view). (1) J1/P1 ECM connector (2) J2/P2 ECM connector
Illustration 2 g01206554
P1 ECM connector (P1-48) +Battery (P1-52) +Battery (P1-53) +Battery (P1-55) +Battery (P1-57) +Battery (P1-61) −Battery (P1-63) −Battery (P1-65) −Battery (P1-67) −Battery (P1-69) −Battery (P1-70) Keyswitch
Table 2
1. Inspect the Electrical Connectors and the Wiring
A. Turn the main disconnect switch to the OFF position.
B. Thoroughly inspect the ECM connectors. Also, thoroughly inspect the other connectors for the electrical power circuit. Refer to Troubleshooting, "Electrical Connectors - Inspect" for the proper procedure for inspecting the connectors and the wiring.
   
Electrical connectors    
Results: The connectors and wiring appear to be OK.
Proceed to Test Step 2.
Results: There is a problem in the connectors and/or wiring.
Repair The connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are coupled.
Verify that the repair eliminated the problem.
   
2. Check the Voltage to the ECM
A. Disconnect the ECM connector J1/P1.
B. Restore the electrical power to the ECM.
C. Measure the voltage at the ECM. Measure the voltage between P1-48 and P1-61. Measure the voltage between P1-52 and P1-63. Measure the voltage between P1-53 and P1-65. Measure the voltage between P1-55 and P1-67. Measure the voltage between P1-57 and P1-69. Measure the voltage between P1-70 and P1-63.
   
ECM voltage    
Result: The voltage is 24 3 VDC.
The ECM is receiving the correct voltage. The problem may be intermittent. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".
Result: The voltage is less than 24 3 VDC.
The wiring or components between the battery and the ECM may be preventing the voltage from reaching the ECM.
Proceed to Test Step 3
   
3. Check the Charging Circuit
A. Turn the main disconnect switch to the OFF position.
A. Check the charging circuit.
   
Charging circuit    
Result: The charging system is OK.
Proceed to Test Step 4.
Result: The charging system is not OK.
There is a problem with the charging system. Make the necessary repairs. Refer to Special Instruction, REHS0354, "Charging System Troubleshooting".
Verify that the repair eliminated the problem.
   
4. Load Test the Battery
A. Load-test the battery. Refer to Systems Operation and Testing and Adjusting, "Battery - Test"
   
Load test    
Result: The battery voltage is low or the battery did not pass the load test.
Repair: Recharge or replace the faulty batteries.
Verify that the repair eliminated the problem.
Result: The batteries pass the load test. The measured voltage is between 11.5
Parts monitor Caterpillar catalog:
3558522
MONITOR GP-EXH
Caterpillar
Caterpillar
3501063
MONITOR GP-EXH
Caterpillar
Caterpillar
3495409
MONITOR GP-OPR
Caterpillar
Caterpillar
3400623
MONITOR GP-EXH
Caterpillar
Caterpillar
3386922
MONITOR GP-OPR
Caterpillar
Caterpillar
3386921
MONITOR GP-OPR
Caterpillar
Caterpillar
3809723
MONITOR AR
Caterpillar
Caterpillar
3695647
MONITOR GP-OPR
Caterpillar
Caterpillar
3652721
MONITOR GP-
Caterpillar
Caterpillar
3647591
MONITOR AR
Caterpillar
Caterpillar
3590487
MONITOR GP-OPR
Caterpillar
Caterpillar
3558525
MONITOR GP-EXH
Caterpillar
Caterpillar