1560761 MOTOR GP-PISTON Caterpillar parts
365B, 375, 375 L, 5080
Rating:
Alternative (cross code) number:
CA1560761
156-0761
1560761
CA1560761
156-0761
1560761
Weight: 524 pounds 237 kg.
EXCAVATOR, FRONT SHOVEL,
Related part:
1560761
MOTOR GP-HYD
10R0839
R
Information:
standard configuration for the EMCP 3.2 and for the EMCP 3.3 has only one "Programmable Trip Point" function block. The "Programmable Trip Point" is configured to respond to the %KW of the generator set.Note: The "Programmable Trip Point" feature is not available on the EMCP 3.1 control. The EMCP 3.1 does not monitor power.Note: The "Programmable Trip Point" function cannot be configured to act upon a different parameter from %kW. If a different capability is desired, a custom flash file must be ordered. Contact your technical communicator for details.The set points of the "Programmable Trip Point" are configured by default. If the %kW exceeds 90 percent for 10 seconds, then the output of the "Programmable Trip Point" will become true. The output of the "Programmable Trip Point" will remain true until the %kW drops below 85 percent for 1 second.The output of the "Programmable Trip Point" function can be configured by either of the following:
"Digital Selector 2" to "Relay output 4"
"Digital Selector 7" to "Digital (transistor) Output 1"The set points in the "Programmable Trip Point" function can be changed with the use of the EMCP 3.Programmable Trip Point Function Trigger Condition (Default = Trip Above Threshold) - Selects whether the output will be active if the value is above or below the threshold.Programmable Trip Point Function Percentage Threshold (Default = 90%) - The threshold that the measured parameter must pass in order to change the state of the output. In the default case for %kW, this value is 90 percent of rated kW.Programmable Trip Point Function Hysteresis Percentage (Default = 5%) - Once the output is on, the value must exceed the threshold by the default value before the output turns off again. In the case of the default %kW, the 5 percent value causes the relay to remain on until 85 percent of rated kW is reached. Therefore, if the rated kW is 90 percent, then the output will not switch off until 85 percent is reached. This hysteresis is used to ensure that a value close to the threshold does not cause the output to toggle on and off.Programmable Trip Point Function Trip Activation Delay Time (Default = 10 seconds) - The time that the value must exceed the threshold before the output of the block becomes active. The activation delay time is used in order to ensure that the momentary transients do not trip the relay.Programmable Trip Point Function Trip Deactivation Delay Time (Default = 1 second) - The time that the value must return past the hysteresis threshold before the output of the block becomes inactive again. The deactivation delay time is used in order to ensure that the momentary transients do not deactivate the relay.
"Digital Selector 2" to "Relay output 4"
"Digital Selector 7" to "Digital (transistor) Output 1"The set points in the "Programmable Trip Point" function can be changed with the use of the EMCP 3.Programmable Trip Point Function Trigger Condition (Default = Trip Above Threshold) - Selects whether the output will be active if the value is above or below the threshold.Programmable Trip Point Function Percentage Threshold (Default = 90%) - The threshold that the measured parameter must pass in order to change the state of the output. In the default case for %kW, this value is 90 percent of rated kW.Programmable Trip Point Function Hysteresis Percentage (Default = 5%) - Once the output is on, the value must exceed the threshold by the default value before the output turns off again. In the case of the default %kW, the 5 percent value causes the relay to remain on until 85 percent of rated kW is reached. Therefore, if the rated kW is 90 percent, then the output will not switch off until 85 percent is reached. This hysteresis is used to ensure that a value close to the threshold does not cause the output to toggle on and off.Programmable Trip Point Function Trip Activation Delay Time (Default = 10 seconds) - The time that the value must exceed the threshold before the output of the block becomes active. The activation delay time is used in order to ensure that the momentary transients do not trip the relay.Programmable Trip Point Function Trip Deactivation Delay Time (Default = 1 second) - The time that the value must return past the hysteresis threshold before the output of the block becomes inactive again. The deactivation delay time is used in order to ensure that the momentary transients do not deactivate the relay.
Caterpillar SIS machinery equipment:
Caterpillar SIS
375 & 375 L Excavators 1JM00001-UP (MACHINE) POWERED BY 3406 Engine »
156-0761
MOTOR GP-PISTON
375 and 375 L Excavators 6NK00001-UP (MACHINE) POWERED BY 3406 Engine »
156-0761
MOTOR GP-PISTON
5080 Excavator 6XK00001-UP (MACHINE) POWERED BY 3406B Engine »
156-0761
MOTOR GP-PISTON
5080 Excavator 8SL00001-UP (MACHINE) POWERED BY 3406B Engine »
156-0761
MOTOR GP-PISTON
365B L Excavators 9PZ00001-UP (MACHINE) POWERED BY 3196 Engine »
156-0761
MOTOR GP-PISTON
Caterpillar parts catalog:
Parts motor Caterpillar catalog:
1741486
MOTOR AS-BLOWER
30/30, 307, 307B, 312, 312B L, 315, 315B L, 317, 317B LN, 318B, 320B, 322B L, 322B LN, 325B L, 325D FM LL, 330, 330B L, 330D FM, 345B, 345B II, 345B II MH, 345B L, 350, 365B, 365B II, 375, 375 L, 385B...
30/30, 307, 307B, 312, 312B L, 315, 315B L, 317, 317B LN, 318B, 320B, 322B L, 322B LN, 325B L, 325D FM LL, 330, 330B L, 330D FM, 345B, 345B II, 345B II MH, 345B L, 350, 365B, 365B II, 375, 375 L, 385B...
1129565
MOTOR AS-BLOWER
307, 312, 315, 317, 322 FM L, 330, 330 L, 350, 375, 375 L, 5080, 769D, 771D, 773D, 775D, 776D, 777D, 914G, 924G, 928G, 938G, IT14G, IT28G, IT38G
307, 312, 315, 317, 322 FM L, 330, 330 L, 350, 375, 375 L, 5080, 769D, 771D, 773D, 775D, 776D, 777D, 914G, 924G, 928G, 938G, IT14G, IT28G, IT38G
1741494
MOTOR AS-BLOWER
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 140H, 140H ES, 140H NA, 160H, 160H ES, 160H NA, 312B L, 315B L, 317B LN, 318B, 375 L, 5130, 5230, 611, 613C II, 615C, 621F, 621G, 623F, 623G, 627F, 6...
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 140H, 140H ES, 140H NA, 160H, 160H ES, 160H NA, 312B L, 315B L, 317B LN, 318B, 375 L, 5130, 5230, 611, 613C II, 615C, 621F, 621G, 623F, 623G, 627F, 6...
1310399
MOTOR AS-WINDOW WIPER
311B, 312B L, 315B L, 317B LN, 318B, 320B, 322B LN, 325B L, 330B L, 345B II, 345B L, 365B, 365B II, 385B, 5090B
311B, 312B L, 315B L, 317B LN, 318B, 320B, 322B LN, 325B L, 330B L, 345B II, 345B L, 365B, 365B II, 385B, 5090B
7Y5468
MOTOR AS-GOVERNOR
375, 375 L, 5080
375, 375 L, 5080
1263015
MOTOR AS-GOVERNOR
375, 5080
375, 5080
1300274
MOTOR AS
350, 375
350, 375
1300272
MOTOR AS
350, 375
350, 375
1300271
MOTOR AS
350, 375
350, 375
1300268
MOTOR AS
350, 375
350, 375
130268
MOTOR AS
375
375
1196788
MOTOR AS
375
375
1140661
MOTOR & MTG GP-SWING
325B, 325B L, 330B, 330B L, M325B, W330B
325B, 325B L, 330B, 330B L, M325B, W330B
1765107
MOTOR GP-SWING
320B, 320B FM LL, 320B U, 321B
320B, 320B FM LL, 320B U, 321B
2087084
MOTOR & MTG GP-PROPEL
CP-573E, CP-663E, CS-563E, CS-583E, CS-663E, CS-683E
CP-573E, CP-663E, CS-563E, CS-583E, CS-663E, CS-683E
3203667
MOTOR GP-PISTON
623H, 623K, 623K LRC
623H, 623K, 623K LRC
1239296
MOTOR & MTG GP-VIBRATORY
CB-434B
CB-434B
1757933
MOTOR GP-PISTON
AP-800C, AP-900B, BG-225B
AP-800C, AP-900B, BG-225B
4398751
MOTOR GP-PISTON
SAT223, SAT22DB, SAT318, SAT318T, SAT420, SAT630
SAT223, SAT22DB, SAT318, SAT318T, SAT420, SAT630
2379866
MOTOR & MTG GP-GENERATOR
AP-1055B
AP-1055B
2522459
MOTOR & MTG GP-PROPEL
PS-150C
PS-150C