2644407 MOTOR GP-WINDOW WIPER Caterpillar parts
246C, 256C, 262C, 272C, 277C, 279C, 287C, 289C, 297C, 299C
Rating:
Alternative (cross code) number:
CA2644407
264-4407
2644407
CA2644407
264-4407
2644407
Weight: 2 pounds 1 kg.
COMPACT TRACK LOADER, SKID STEER LOADER,
Compatible equipment models: 2644407:
Information:
Introductionto Flow Control Valves
Flow control consists of controlling the volume of oil flow in a circuit or out of a circuit. Controlling flow in a hydraulic circuit can be accomplished in several ways.The most common way is by installing an orifice. When an orifice is installed, the orifice presents a higher than normal restriction to the pump flow. The higher restriction increases the oil pressure. The increase in oil pressure causes some of the oil to take another path. The path may be through another circuit or the path may be over a relief valve.Also discussed are non-compensated and compensated flow control valves.Orifice
An orifice is a small opening in the oil flow path. Flow through an orifice is affected by several factors.Three of the most common factors are listed below:
The temperature of the oil.
The size of the orifice.
The pressure differential across the orifice.Temperature
The oil viscosity changes with changes in temperature. Viscosity is a measurement of the oil's resistance to flow at a specific temperature. Hydraulic oil becomes thinner and flows more readily as the temperature increases.Orifice Size
The size of the orifice controls the flow rate through the orifice. A common example is a hole in a garden hose. A small pin hole will leak in the form of a drip. A larger hole will leak in the form of a stream. The hole, whether small or large, meters a flow of water to the outside of the hose. The amount of water that is metered depends on the size of the orifice.The orifice size may be fixed or variable. Check Valve With A Fixed Orifice
Illustration 1 g01064413
Illustration 1 shows an example of a check valve with a fixed orifice that is commonly used in construction equipment. The fixed orifice is a hole through the center of the check valve. When oil flow is in the normal direction the valve opens. The oil flow will allow oil to flow around the valve and through the orifice. When oil attempts to flow in the reverse direction, the valve closes. All reverse flowing oil must flow through the orifice that controls the flow rate.Variable Orifice
Illustration 2 g01064414
Illustration 2 shows a variable orifice in the form of a needle valve. In the needle valve, the size of the orifice is changed by the positioning of the valve tip in relation to the valve seat.The oil flow through the needle valve must make a 90° turn and pass between the valve tip and the valve seat. The needle valve is one of the most frequently used variable orifices.When the valve stem is turned counterclockwise, the orifice becomes larger and the flow increases through the valve.When the valve stem is turned clockwise, the orifice becomes smaller and the flow decreases through the valve.The schematic in Illustration 3 and Illustration 4 consist of a positive displacement pump, a relief valve, and a variable orifice. The relief valve is set at 3445 kPa (500 psi) and limits maximum pressure in the system. The orifice may be adjusted to
Flow control consists of controlling the volume of oil flow in a circuit or out of a circuit. Controlling flow in a hydraulic circuit can be accomplished in several ways.The most common way is by installing an orifice. When an orifice is installed, the orifice presents a higher than normal restriction to the pump flow. The higher restriction increases the oil pressure. The increase in oil pressure causes some of the oil to take another path. The path may be through another circuit or the path may be over a relief valve.Also discussed are non-compensated and compensated flow control valves.Orifice
An orifice is a small opening in the oil flow path. Flow through an orifice is affected by several factors.Three of the most common factors are listed below:
The temperature of the oil.
The size of the orifice.
The pressure differential across the orifice.Temperature
The oil viscosity changes with changes in temperature. Viscosity is a measurement of the oil's resistance to flow at a specific temperature. Hydraulic oil becomes thinner and flows more readily as the temperature increases.Orifice Size
The size of the orifice controls the flow rate through the orifice. A common example is a hole in a garden hose. A small pin hole will leak in the form of a drip. A larger hole will leak in the form of a stream. The hole, whether small or large, meters a flow of water to the outside of the hose. The amount of water that is metered depends on the size of the orifice.The orifice size may be fixed or variable. Check Valve With A Fixed Orifice
Illustration 1 g01064413
Illustration 1 shows an example of a check valve with a fixed orifice that is commonly used in construction equipment. The fixed orifice is a hole through the center of the check valve. When oil flow is in the normal direction the valve opens. The oil flow will allow oil to flow around the valve and through the orifice. When oil attempts to flow in the reverse direction, the valve closes. All reverse flowing oil must flow through the orifice that controls the flow rate.Variable Orifice
Illustration 2 g01064414
Illustration 2 shows a variable orifice in the form of a needle valve. In the needle valve, the size of the orifice is changed by the positioning of the valve tip in relation to the valve seat.The oil flow through the needle valve must make a 90° turn and pass between the valve tip and the valve seat. The needle valve is one of the most frequently used variable orifices.When the valve stem is turned counterclockwise, the orifice becomes larger and the flow increases through the valve.When the valve stem is turned clockwise, the orifice becomes smaller and the flow decreases through the valve.The schematic in Illustration 3 and Illustration 4 consist of a positive displacement pump, a relief valve, and a variable orifice. The relief valve is set at 3445 kPa (500 psi) and limits maximum pressure in the system. The orifice may be adjusted to
Caterpillar parts catalog:
Parts motor Caterpillar catalog:
3305011
MOTOR GP-WINDOW WIPER
246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 299D, 299D XHP
246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 299D, 299D XHP
2788720
MOTOR GP-GEAR
272C, 297C, 299C
272C, 297C, 299C
2582408
MOTOR & MTG GP-HYDROSTATIC
246C, 256C, 262C, 262C2
246C, 256C, 262C, 262C2
2582409
MOTOR & MTG GP-HYDROSTATIC
246C, 256C, 262C, 262C2
246C, 256C, 262C, 262C2
2582442
MOTOR GP-PISTON
246C, 256C, 262C, 262C2
246C, 256C, 262C, 262C2
2582520
MOTOR GP-PISTON
246C, 256C, 262C, 262C2
246C, 256C, 262C, 262C2
2582521
MOTOR GP-PISTON
246C, 256C, 262C, 262C2
246C, 256C, 262C, 262C2
2582605
MOTOR GP-PISTON
246C, 256C, 262C, 272C, 272D, 272D XHP
246C, 256C, 262C, 272C, 272D, 272D XHP
2582415
MOTOR & MTG GP-HYDROSTATIC
272C, 272D, 272D XHP
272C, 272D, 272D XHP
2955440
MOTOR
216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 246C, 247B, 247B3, 252B, 252B3, 256C, 257B, 257B3, 259B3, 262C, 262C2, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 2...
216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 246C, 247B, 247B3, 252B, 252B3, 256C, 257B, 257B3, 259B3, 262C, 262C2, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 2...
2582577
MOTOR GP-GEAR
216B3, 226B3, 236B3, 236D, 242B3, 242D, 246C, 246D, 247B3, 252B3, 256C, 257B3, 257D, 259B3, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C...
216B3, 226B3, 236B3, 236D, 242B3, 242D, 246C, 246D, 247B3, 252B3, 256C, 257B3, 257D, 259B3, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C...
2602657
MOTOR GP-PISTON
256C, 262C, 272C, 277C, 287C, 297C, HM312, HM315
256C, 262C, 272C, 277C, 287C, 297C, HM312, HM315
2602657
MOTOR GP-PISTON
256C, 262C, 272C, 277C, 287C, 297C, HM312, HM315
256C, 262C, 272C, 277C, 287C, 297C, HM312, HM315
2582577
MOTOR GP-GEAR
216B3, 226B3, 236B3, 236D, 242B3, 242D, 246C, 246D, 247B3, 252B3, 256C, 257B3, 257D, 259B3, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C...
216B3, 226B3, 236B3, 236D, 242B3, 242D, 246C, 246D, 247B3, 252B3, 256C, 257B3, 257D, 259B3, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C...
2955440
MOTOR
216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 246C, 247B, 247B3, 252B, 252B3, 256C, 257B, 257B3, 259B3, 262C, 262C2, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 2...
216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 246C, 247B, 247B3, 252B, 252B3, 256C, 257B, 257B3, 259B3, 262C, 262C2, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 2...
2202000
MOTOR GP-WINDOW WIPER
414E, 416E, 420E, 422E, 428E, 430E, 432E, 434E, 442E, 444E, 450E
414E, 416E, 420E, 422E, 428E, 430E, 432E, 434E, 442E, 444E, 450E
2564580
MOTOR AS
120H, 120M, 12H, 12M, 135H, 140H, 140M, 143H, 14H, 14M, 160H, 160M, 163H, 16H, 16M, 24M, 416E, 420E, 430E, D3G, D3K XL, D4G, D4K XL, D5G, D5K LGP, D6K LGP, D6N, D6R II, D6R III, D6T, D7R II, D8T, D9T
120H, 120M, 12H, 12M, 135H, 140H, 140M, 143H, 14H, 14M, 160H, 160M, 163H, 16H, 16M, 24M, 416E, 420E, 430E, D3G, D3K XL, D4G, D4K XL, D5G, D5K LGP, D6K LGP, D6N, D6R II, D6R III, D6T, D7R II, D8T, D9T
2562843
MOTOR
TH220B, TH330B
TH220B, TH330B
6T6529
MOTOR AS-WIPER
428, 446, 65
428, 446, 65
4425661
MOTOR GP-PISTON
277D, 287D
277D, 287D
4414769
MOTOR-WIPER
424B, 424B HD
424B, 424B HD
4424463
MOTOR-WINDOW WIPER
424B, 424B HD
424B, 424B HD