4852984 MOUNT AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA4852984
485-2984
4852984
CA4852984
485-2984
4852984
Weight: 7 pounds 3 kg.
Information:
Do not operate the generator if the windings are wet. If the generator is operated when the windings are wet, damage can occur due to insulation breakdown.
Personal injury or death can result from improper troubleshooting and repair procedures.The following troubleshooting and repair procedures should only be performed by qualified personnel familiar with this equipment.
Refer to Safety Section, "Generator Isolating for Maintenance" for information regarding the procedure to isolate the generator safely.When moisture is present or when moisture is suspected in a generator, the generator must be dried before being energized.If the drying procedure does not restore the insulation resistance to an acceptable value, the winding should be reconditioned.Drying Methods
The following methods can be used for drying a generator:
Self-circulating air method
Oven method
Controlled current method
Energize the optional space heaters.
Do not allow the winding temperature to exceed 85 °C (185.0 °F). Temperatures that are greater than 85 °C (185.0 °F) will damage the winding insulation.
Self-Circulating Air Method
Run the engine and disconnect the generator load. Disconnecting the generator load will help circulate air. Operate the generator space heaters.Oven Method
Place the entire generator inside a forced air drying oven for 4 hours at 65 °C (149 °F).
Use a forced air type oven rather than a radiant type oven.Radiant type ovens can cause localized overheating.
Controlled Current Method
Illustration 1 g00614674
External Power Source Circuit
(1) Battery (12 VDC)
(2) Rheostat (15 ohm 25 W)
(3) Exciter Field (Stator "L1")
Table 1
TOOLS NEEDED
Quantity Part Number Description
1 225-8266 Clamp-on ammeter (1200 A)
1 External power source circuit Heat can be used in order to dry the generator windings. This heat can be created by allowing a controlled current to flow through the generator. No high voltages are generated during the following procedure. Therefore, insulation breakdown will not occur.
Make an external power source. Refer to Illustration 1.
Disconnect F1+ from the voltage regulator. Disconnect F2- from the voltage regulator. Disconnect the generator load. Connect the generator output leads T0, T1, T2, and T3 together. Install the clamp-on ammeter to generator output lead T1. Note: When the line current is measured on multiple lead units, measure the current in each conductor per phase. The currents can then be added.
Refer to Illustration 1. Adjust the rheostat to the maximum resistance value. Connect the external power source to wires F1+ and F2-.
Start the generator set. Run the generator set at idle speed.
Do not exceed the rated phase current that is listed on the generator nameplate. Exceeding the rated phase current will easily damage the generator windings.
Monitor the phase current. In order to maintain use of the circuits for the protection of safety, use the "EMCP 4" to increase the engine rpm gradually. Increase the engine rpm until one of the following conditions are met:
The rated phase current is obtained.
The full generator set speed is obtained.
If more phase current is necessary, slowly turn the rheostat. Turn the rheostat until the rated phase current is reached.
On an hourly basis, stop the drying procedure. Check the insulation resistance. Repeat the above steps until the insulation resistance is acceptable. Guidelines
Cat SIS web machinery list:
Parts mount Caterpillar catalog:
4851347
MOUNT AS
Caterpillar
Caterpillar
4845529
MOUNT AS
Caterpillar
Caterpillar
4828998
MOUNT AS
Caterpillar
Caterpillar
4828995
MOUNT AS
Caterpillar
Caterpillar
4757089
MOUNT
Caterpillar
Caterpillar
4519926
MOUNT AS
Caterpillar
Caterpillar
4329125
MOUNT
Caterpillar
Caterpillar
4315852
MOUNT
Caterpillar
Caterpillar
3960660
MOUNT AS
Caterpillar
Caterpillar
3822038
MOUNT AS
Caterpillar
Caterpillar
3822035
MOUNT AS
Caterpillar
Caterpillar
3820760
MOUNT AS
Caterpillar
Caterpillar