AVSPARE.COM
parts catalog

MOUNTING GP-CONTROL 3047941 - Caterpillar


3047941 MOUNTING GP-CONTROL Caterpillar parts C175-16
Rating:
14
Alternative (cross code) number:
CA3047941
304-7941
3047941
Caterpillar 3047941 MOUNTING GP-CONTROL

Buy MOUNTING GP-CONTROL 3047941 Caterpillar genuine, new aftermarket tractor parts with delivery
GENERATOR SET,

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$30.00
 

02 Apr 2021

-: -
Troy-Bilt Drill Bit JumpStart for Trimmers & Other Handheld Equipment 3047941
TROY BILT GREAT SALE PRICE || Special Features:Electric Start Suitable For Use With:Troy-Bilt And Craftsman Electric Start Capable Units Usage:For String Trimmers || Chuck Attaches To Drill For Easy Start || Allows For Quick And Easy Starting Of JumpStart Capable String Trimmers And Other Small Engine Products || Bit/Chuck Will Fit In Any Standard 3/8 In Corded Or Cordless Drill
$106.77
 

05 Jan 2021

-: -
Genuine Cummins 3047941 LEVER,THROTTLE
Factory Direct Shipped Genuine Cummins Part || Availability can vary, please contact for availability before ordering || May take up to 20 business days to ship. Shipping depends upon availability
$33.41
 

11 May 2021
1.1[0.50] Pounds
US: NRI Industrial
STACKPOLE 304-79-41 5 Potentiometer D635339
Stackpole CUSTOM IDENTIFIER: STACKPOLE 304-79-41 D635339
Number on catalog scheme:
  For full view, you need register

Compatible equipment models: 3047941:

GENERATOR SET  C175-16   Caterpillar

Information:

Using The New Recommendations
A new maintenance-free battery can normally be installed in a machine without charging and load testing. However, if a battery has been in storage for a long time, it can be partially discharged. Do the following steps before installing a maintenance free battery.
1. Measure open circuit voltage with a 6V7070 Multimeter with the selector on the 20 volt DC scale.2. If open circuit voltage is 12.40 volts or more, the battery can be installed.3. If open circuit voltage is less than 12.00 volts, do NOT sell the battery as a new battery.4. If open circuit voltage is 12.00 to 12.39 volts, charge the battery. Select the amps charge rate and the charging time from the following tables.
During charging, on-charge voltage must not exceed 16.0 volts. In order to keep on-charge voltage below 16.0 volts, charging amps may need to be reduced near the end of charging.
5. After charging, load test the battery at one-half the cold cranking amp (CCA) rating of the battery. Refer to PEKP9100 for CCA rating. If the voltage at 15 seconds is 9.5 volts or more, install the battery. If the voltage at 15 seconds is less than 9.5 volts, do NOT sell the battery as a new battery.