1W2572 MUFFLER AS. Caterpillar parts
225
Rating:
Alternative (cross code) number:
CA1W2572
1W-2572
1W2572
CA1W2572
1W-2572
1W2572
Weight: 29 pounds 13 kg.
Information:
BODY DIAMETER/WIDTH
254
mm
BODY LENGTH
434.8
mm
INLET ID
102.39
mm
OUTLET OD
127.97
mm
OVAL HEIGHT
381
mm
OVERALL LENGTH
547.6
mm
PROTECTIVE SHIELD
N
WITH EJECTOR
N
WITH MOUNTING BRACKET
N
WITH OUTER WRAP
N
EXCAVATOR,
Related part:
1W2572
MUFFLER-AS-YM
2472663
CL
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
1W2572 Muffler fits Caterpillar 229 225B
ZBOX 【FITMENT MODELS】 Fits Caterpillar 229 - 225B || 【DESIGNED TO REPLACE】 114532 - 1W2572 - 1W-2572 - 1W2572-A - CA1W2572 - H1W2572 - MUK40-0069 || 【FITMENT MODELS】 Fits Caterpillar 225B - 229 - 225 - 215 || 【AMERICAN OWNED & OPERATED】Fully owned and operated within the United States, our business is dedicated to contributing to local economies, supporting American jobs, and fostering community growth. || 【QUALITY REPLACEMENT】Engineered for durability and performance, our parts meet or exceed OEM specifications. Ideal for construction and agriculture machinery, ensuring reliability and efficiency in tough working conditions.
ZBOX 【FITMENT MODELS】 Fits Caterpillar 229 - 225B || 【DESIGNED TO REPLACE】 114532 - 1W2572 - 1W-2572 - 1W2572-A - CA1W2572 - H1W2572 - MUK40-0069 || 【FITMENT MODELS】 Fits Caterpillar 225B - 229 - 225 - 215 || 【AMERICAN OWNED & OPERATED】Fully owned and operated within the United States, our business is dedicated to contributing to local economies, supporting American jobs, and fostering community growth. || 【QUALITY REPLACEMENT】Engineered for durability and performance, our parts meet or exceed OEM specifications. Ideal for construction and agriculture machinery, ensuring reliability and efficiency in tough working conditions.
1W2572 Muffler Assembly Fits Caterpillar Excavator Model 215 225B
Sourcefy Made with the Highest Quality Components Available || 6 Months Unlimited Warranty || Pressure and Computer tested for consistent Quality and unsurpassed reliability || Fits Caterpillar Excavator Model 215 225B
Sourcefy Made with the Highest Quality Components Available || 6 Months Unlimited Warranty || Pressure and Computer tested for consistent Quality and unsurpassed reliability || Fits Caterpillar Excavator Model 215 225B
Compatible equipment models: 1W2572:
Information:
Receiving Inspection
If the generator is received during cold weather, allow the unit to reach room temperature before you remove the protective packing material. Warming the generator to room temperature will prevent the following problems:
Water condensation on cold surfaces
Early failures due to wet windings
Early failures due to wet insulating materialsUnpacking
Moving the Generator
Improper lift rigging can allow unit to tumble causing injury and damage.
Do not use the engine lifting eyes to remove the engine and generator together.
Unpack the equipment with care in order to avoid scratching painted surfaces. Move the unit to the mounting location. Follow the instructions under the "Product Lifting" topic. The hoist and the hoist cables should have a rating that is greater than the weight of the generator.Location
The location of the generator must comply with all local regulations. The location of the generator must also comply with all special industrial regulations. Locate the generator in an area that meets the following requirements:
Clean
Dry
Well ventilated
Easily accessible for inspection and maintenanceDo not obstruct air inlet openings. Do not obstruct discharge openings. Air flow must reach these openings. If the generator is exposed to harsh environmental conditions, the generator can be modified in the field in order to add filters and space heaters. In addition, a more rigid periodic maintenance schedule should be established.Note: For further information concerning the installation of this generator set, see the appropriate Application and Installation Guide.Protective Devices
The output to the load of the generator should always be protected with an overload protection device such as a circuit breaker or fuses. Fuses should be sized by using the lowest possible current rating. However, this rating must be above the current rating for full load. A common recommendation is 115 percent of rated current. Determine the size of fuses or determine the size of circuit breakers in accordance with NEMA, IEC, and Local Electrical Codes.Storage
If the generator is not installed immediately, refer to the "Product Storage" topic for the proper considerations for storing the unit.
If the generator is received during cold weather, allow the unit to reach room temperature before you remove the protective packing material. Warming the generator to room temperature will prevent the following problems:
Water condensation on cold surfaces
Early failures due to wet windings
Early failures due to wet insulating materialsUnpacking
Moving the Generator
Improper lift rigging can allow unit to tumble causing injury and damage.
Do not use the engine lifting eyes to remove the engine and generator together.
Unpack the equipment with care in order to avoid scratching painted surfaces. Move the unit to the mounting location. Follow the instructions under the "Product Lifting" topic. The hoist and the hoist cables should have a rating that is greater than the weight of the generator.Location
The location of the generator must comply with all local regulations. The location of the generator must also comply with all special industrial regulations. Locate the generator in an area that meets the following requirements:
Clean
Dry
Well ventilated
Easily accessible for inspection and maintenanceDo not obstruct air inlet openings. Do not obstruct discharge openings. Air flow must reach these openings. If the generator is exposed to harsh environmental conditions, the generator can be modified in the field in order to add filters and space heaters. In addition, a more rigid periodic maintenance schedule should be established.Note: For further information concerning the installation of this generator set, see the appropriate Application and Installation Guide.Protective Devices
The output to the load of the generator should always be protected with an overload protection device such as a circuit breaker or fuses. Fuses should be sized by using the lowest possible current rating. However, this rating must be above the current rating for full load. A common recommendation is 115 percent of rated current. Determine the size of fuses or determine the size of circuit breakers in accordance with NEMA, IEC, and Local Electrical Codes.Storage
If the generator is not installed immediately, refer to the "Product Storage" topic for the proper considerations for storing the unit.
Caterpillar parts catalog:
Parts muffler Caterpillar catalog:
2W2402
MUFFLER GP
225, 225D, 229, 229D
225, 225D, 229, 229D
1P2667
MUFFLER GP
225, 229
225, 229
6N3964
MUFFLER ASSEM.
215, 225
215, 225
4P4010
MUFFLER AS
215B
215B
4P1463
MUFFLER AS
245B
245B
7C6398
MUFFLER AS
245B
245B
7E5663
MUFFLER AS
225D, 231D, AP-655C
225D, 231D, AP-655C
4W3632
MUFFLER AS
235B, 235C
235B, 235C