5017967 NOZZLE Caterpillar parts
Rating:
Alternative (cross code) number:
CA5017967
501-7967
5017967
CA5017967
501-7967
5017967
Weight: 0.01 pounds 0 kg.
Information:
Illustration 1 g01442849
Axle Oiler Cooler Solenoid connectionsThis diagnostic code is associated with the Axle Oil Cooler solenoid. The FMI 05 means that the ECM has detected that the current for the solenoid circuit is below normal.The following conditions could cause this diagnostic code to be activated:
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECM has failed. This is unlikely. Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit meet the following requirements: clean, secure and good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.Test Step 1. CHECK THE SOLENOID
Disconnect the solenoid from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire 987-WH) to contact 2 (wire 975-WH).
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the CID 2825 FMI 05 diagnostic code.Expected Result:The CID 2825 FMI 05 diagnostic code is no longer active. A CID 2825 FMI 06 diagnostic code becomes active when the jumper wire is connected.Results:
YES - The CID 2825 FMI 05 diagnostic code is no longer active. A CID 2825 FMI 06 diagnostic code becomes active when the jumper wire is connected. The solenoid has failed.Repair: Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.STOP
NO - The CID 2825 FMI 05 diagnostic code remains active. The jumper wire does not affect the status of the active diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2.Test Step 2. CHECK THE CIRCUIT FOR AN OPENThe jumper wire that was installed in the previous Test Step remains in place.
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the (machine harness) ECM connector J2 from the ECM.
At the machine harness connector J2 for the ECM, measure the resistance from contact J2-2 (wire 987-WH) to contact J2-4 (wire 975-WH).
While observing the multimeter resistance measurement, wiggle the machine harness connectors for the ECM and wiggle the machine harness connector for the solenoid. Gently pull on the wires and move the wires all around.Expected Result:The resistance measurement is less than 5.0 ohms at all times during the manipulation of the harness and connectors.Results:
OK - The resistance measurement is less than 5.0 ohms. The resistance measurement is not
Caterpillar parts catalog:
Parts nozzle Caterpillar catalog:
4537869
NOZZLE AS-FUEL VALVE
Caterpillar
Caterpillar
5223004
NOZZLE GP-UNIT INJECTOR
Caterpillar
Caterpillar
5222884
NOZZLE AS-UNIT INJECTOR
Caterpillar
Caterpillar
5243903
NOZZLE
Caterpillar
Caterpillar
5011294
NOZZLE
Caterpillar
Caterpillar
4818076
NOZZLE
Caterpillar
Caterpillar
4482860
NOZZLE GP-WATER
Caterpillar
Caterpillar
4458758
NOZZLE GP-WATER
Caterpillar
Caterpillar
4458757
NOZZLE GP-WATER
Caterpillar
Caterpillar
4287041
NOZZLE-SPRAY
Caterpillar
Caterpillar
5017933
NOZZLE
Caterpillar
Caterpillar
4832798
NOZZLE GP-UNIT INJECTOR
Caterpillar
Caterpillar