6F5227 NUT Caterpillar parts
Rating:
Alternative (cross code) number:
CA6F5227
6F-5227
6F5227
CA6F5227
6F-5227
6F5227
Weight: 0.25 pounds 0 kg.
Information:
Illustration 1 g03371292
Transmission Clutch Solenoid Valves
(1) Transmission solenoid valve (No. 8)
(2) Transmission solenoid valve (No. 7)
(3) Transmission solenoid valve (No. 5)
(4) Transmission solenoid valve (No. 6)
(5) Transmission solenoid valve (No. 3)
(6) Transmission solenoid valve (No. 4)
(7) Transmission solenoid valve (No. 1)
(8) Transmission solenoid valve (No. 2)
Illustration 2 g03367562
Illustration of the electrical connections for the Transmission Solenoid 8
This diagnostic code is associated with the "Transmission Solenoid 8". The FMI 06 diagnostic code means that the Transmission ECM has determined that the current of the solenoid circuit is above normal.Some possible causes of this diagnostic code are listed below:
The energize circuit of the solenoid is shorted to ground.
The solenoid has failed.
The ECM has failed. This situation is unlikely. Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, that all connections are secure and that all connections are in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Note: The resistance of the solenoid coil should be 8.7 .4 ohms at 25 °C (77.0 °F).Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:The active CID 1408 FMI 06 diagnostic code changes to a CID 1408 FMI 05 diagnostic code when the solenoid is disconnected.Results:
YES - The active CID 1408 FMI 06 diagnostic code changes to a CID 1408 FMI 05 diagnostic code when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" to verify the solenoid failure. Replace the solenoid.STOP
NO - The CID 1408 FMI 06 remains active when the solenoid is disconnected. The solenoid is not causing the problem. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connectors J1 and J2 from the Transmission ECM.
At the machine harness connectors of the ECM, measure the resistance from the contact J1-62 (wire 903-GY(Grey)) to frame ground. Measure the resistance from the contact J1-62 (wire 903-GY(Grey)) to all of the other J1 and J2 contacts that are used in the Transmission ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - One or more of the resistance measurements is less than 5000 ohms. There is a
Parts nut Caterpillar catalog:
6F4715
NUT 6B454
Caterpillar
Caterpillar
6F4312
NUT
Caterpillar
Caterpillar
6F3647
NUT
Caterpillar
Caterpillar
6F2846
NUT
Caterpillar
Caterpillar
6F0647
NUT-JAM
Caterpillar
Caterpillar
6E6125
NUT-SEAL (16)
Caterpillar
Caterpillar
6F7951
NUT-HEX
Caterpillar
Caterpillar
6F7404
NUT
Caterpillar
Caterpillar
6F7169
NUT
Caterpillar
Caterpillar
6F7006
NUT-JAM
Caterpillar
Caterpillar
6F6934
NUT
Caterpillar
Caterpillar
6F5557
NUT A.-CAPSULE
Caterpillar
Caterpillar