8V9720 NUT-ADJUSTING Caterpillar parts
814B, 815B, 816B, 966D, 966F, 966G, D25D, D350E, D400E, D40D
Rating:
Alternative (cross code) number:
CA8V9720
8V-9720
8V9720
CA8V9720
8V-9720
8V9720
Weight: 1 pounds 0 kg.
ARTICULATED TRUCK, WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$48.60
17 Dec 2021
US: Florida-Parts-Z
8V9720 - NUT-Adjustment 8D2653 fit Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
Compatible equipment models: 8V9720:
Information:
Conditions Which Generate This Code:
Illustration 1 g00530806
System schematic for the spare outputThe spare output on the GSC+ is strictly for the use of customers. The spare output is programmable in order to activate under a variety of conditions. The default parameter programming causes the GSC+ to activate the output when the engine is in cooldown mode. The GSC+ treats a CID 0334 FMI 03 as an alarm fault. For more information, see Systems Operation, "Spare Input/Output Programming OP6". The customer and/or the dealer are responsible for documenting and troubleshooting any connections to this output.The voltage on the spare output is approximately 5.0 DCV when there are no connections and when the spare output is not active. When the spare output is active, the voltage on the spare output is approximately 0 volts. The spare output is capable of drawing (sinking) approximately 100 mA.The possible cause of a CID 0334 FMI 03 is a short to battery positive of the spare output signal.Troubleshooting of a spare output fault is direct. The FMI defines the fault. FMI 03 occurs when the spare output is shorted to "B+". In order to find the exact cause of the fault, use the following information.
FMI information
system schematic of spare output
documentation of the customer
documentation of the dealerTest Step 1. CHECK THE GENERATOR SET CONTROL
Verify that the CID 0334 FMI 03 diagnostic code is active.
Disconnect the wire from contact 36 of the GSC+.
Measure the voltage between contact 36 of the GSC+ and frame ground.Expected Result:The voltage is approximately 5 1.0 DCV.Results:
OK - The voltage is approximately 5 1.0 DCV. The voltage is correct. Proceed to test step 2.
NOT OK - The voltage is NOT approximately 5 1.0 DCV. The voltage is NOT correct. The GSC+ has failed.Repair: It is unlikely that the GSC+ has failed. Exit this diagnostic code procedure and repeat the CID 0334 FMI 03 diagnostic code procedure again. If the cause of the failure is still unknown, then replace the GSC+. Stop.Test Step 2. CHECK FOR A SHORT TO "B+" IN THE WIRING OF THE SPARE OUTPUT
Disconnect the "B-" terminal from the battery.
Disconnect the wire from contact 36 of the GSC.
Disconnect the other end of the wire at the customer device.
Measure the resistance between the wire that was disconnected from contact 36 of the GSC+ and the "B+" contact of the GSC+.Expected Result:The resistance is greater than 5000 ohms.Results:
OK - The resistance is greater than 5000 ohms. The circuit is correct. 3
NOT OK - The resistance is less than 5000 ohms. The circuit is not correct. The spare output is shorted to "B+".Repair: Repair the wiring of the spare output relay. Stop.Test Step 3. RECONNECT TO CUSTOMER DEVICE
Reconnect the wire to the customer device.
Reconnect the wire that was disconnected from contact 36 to the GSC+
Turn the ESC switch to STOP and check if the diagnostic code is still active.Expected Result:The diagnostic code is not active.Results:
OK - The diagnostic code is not active. It is likely that the problem was in the
Illustration 1 g00530806
System schematic for the spare outputThe spare output on the GSC+ is strictly for the use of customers. The spare output is programmable in order to activate under a variety of conditions. The default parameter programming causes the GSC+ to activate the output when the engine is in cooldown mode. The GSC+ treats a CID 0334 FMI 03 as an alarm fault. For more information, see Systems Operation, "Spare Input/Output Programming OP6". The customer and/or the dealer are responsible for documenting and troubleshooting any connections to this output.The voltage on the spare output is approximately 5.0 DCV when there are no connections and when the spare output is not active. When the spare output is active, the voltage on the spare output is approximately 0 volts. The spare output is capable of drawing (sinking) approximately 100 mA.The possible cause of a CID 0334 FMI 03 is a short to battery positive of the spare output signal.Troubleshooting of a spare output fault is direct. The FMI defines the fault. FMI 03 occurs when the spare output is shorted to "B+". In order to find the exact cause of the fault, use the following information.
FMI information
system schematic of spare output
documentation of the customer
documentation of the dealerTest Step 1. CHECK THE GENERATOR SET CONTROL
Verify that the CID 0334 FMI 03 diagnostic code is active.
Disconnect the wire from contact 36 of the GSC+.
Measure the voltage between contact 36 of the GSC+ and frame ground.Expected Result:The voltage is approximately 5 1.0 DCV.Results:
OK - The voltage is approximately 5 1.0 DCV. The voltage is correct. Proceed to test step 2.
NOT OK - The voltage is NOT approximately 5 1.0 DCV. The voltage is NOT correct. The GSC+ has failed.Repair: It is unlikely that the GSC+ has failed. Exit this diagnostic code procedure and repeat the CID 0334 FMI 03 diagnostic code procedure again. If the cause of the failure is still unknown, then replace the GSC+. Stop.Test Step 2. CHECK FOR A SHORT TO "B+" IN THE WIRING OF THE SPARE OUTPUT
Disconnect the "B-" terminal from the battery.
Disconnect the wire from contact 36 of the GSC.
Disconnect the other end of the wire at the customer device.
Measure the resistance between the wire that was disconnected from contact 36 of the GSC+ and the "B+" contact of the GSC+.Expected Result:The resistance is greater than 5000 ohms.Results:
OK - The resistance is greater than 5000 ohms. The circuit is correct. 3
NOT OK - The resistance is less than 5000 ohms. The circuit is not correct. The spare output is shorted to "B+".Repair: Repair the wiring of the spare output relay. Stop.Test Step 3. RECONNECT TO CUSTOMER DEVICE
Reconnect the wire to the customer device.
Reconnect the wire that was disconnected from contact 36 to the GSC+
Turn the ESC switch to STOP and check if the diagnostic code is still active.Expected Result:The diagnostic code is not active.Results:
OK - The diagnostic code is not active. It is likely that the problem was in the
Cat SIS web machinery list:
Parts nut Caterpillar catalog:
3K7161
NUT
725, 725C, 730, 730C, 735, 740, 920, 930, 950, 966C, 966D, 977L
725, 725C, 730, 730C, 735, 740, 920, 930, 950, 966C, 966D, 977L
7F9572
NUT
16, 525B, 525C, 535B, 535C, 545, 545C, 611, 613G, 615, 615C, 772, 814B, 814F, 814F II, 815B, 815F, 815F II, 816F, 816F II, 824C, 824G, 824G II, 824H, 824K, 825G, 825G II, 825H, 825K, 826C, 826G, 826G ...
16, 525B, 525C, 535B, 535C, 545, 545C, 611, 613G, 615, 615C, 772, 814B, 814F, 814F II, 815B, 815F, 815F II, 816F, 816F II, 824C, 824G, 824G II, 824H, 824K, 825G, 825G II, 825H, 825K, 826C, 826G, 826G ...
8K6474
NUT AS-SEALING
518, 518C, 528, 528B, 530B, 611, 613B, 613C, 613C II, 615, 615C, 621B, 621E, 621F, 623E, 623F, 627E, 627F, 631C, 631E, 633E II, 637E, 639D, 651E, 657E, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, ...
518, 518C, 528, 528B, 530B, 611, 613B, 613C, 613C II, 615, 615C, 621B, 621E, 621F, 623E, 623F, 627E, 627F, 631C, 631E, 633E II, 637E, 639D, 651E, 657E, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, ...
8D2628
NUT
528, 528B, 530B, 613, 613B, 613C, 613C II, 613G, 814B, 815B, 816B, 950B, 950B/950E, 966D, 966F, 966G, D25C, D25D, D300E, D30C, D350C, D350E, D35C, D35HP, D400, D400E, D40D
528, 528B, 530B, 613, 613B, 613C, 613C II, 613G, 814B, 815B, 816B, 950B, 950B/950E, 966D, 966F, 966G, D25C, D25D, D300E, D30C, D350C, D350E, D35C, D35HP, D400, D400E, D40D
5K5923
NUT-FLANGE
528, 528B, 530B, 613C, 613C II, 621, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 814, 814B, 815B, 824C, 826C, 926, 936, 936F, 950, 950B, 950F, 950F II, 966C, 966D, 966F, 966F II, 966R,...
528, 528B, 530B, 613C, 613C II, 621, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 814, 814B, 815B, 824C, 826C, 926, 936, 936F, 950, 950B, 950F, 950F II, 966C, 966D, 966F, 966F II, 966R,...
4E3644
NUT-ADJUSTMENT
814F, 814F II, 815F, 815F II, 816F, 816F II, 928F, 928G, 928H, 928HZ, 930G, 966F, 966F II, 970F, IT18F, IT28F, IT28G, R1600, R1600G, R1600H
814F, 814F II, 815F, 815F II, 816F, 816F II, 928F, 928G, 928H, 928HZ, 930G, 966F, 966F II, 970F, IT18F, IT28F, IT28G, R1600, R1600G, R1600H
6W4750
NUT-STAKE
14G, 14H, 14H NA, 16G, 16H, 16H NA, 824C, 824G, 824G II, 824H, 824K, 825C, 825G, 825G II, 825H, 825K, 826C, 826G, 826G II, 826H, 826K, 834B, 966G, 966G II, 966H, 966K, 966M, 966M XE, 972G, 972G II, 97...
14G, 14H, 14H NA, 16G, 16H, 16H NA, 824C, 824G, 824G II, 824H, 824K, 825C, 825G, 825G II, 825H, 825K, 826C, 826G, 826G II, 826H, 826K, 834B, 966G, 966G II, 966H, 966K, 966M, 966M XE, 972G, 972G II, 97...
4E2240
NUT-BEARING
545, 545C, 545D, 555D, 814F, 814F II, 815F, 815F II, 816F, 816F II, 966F, 966F II, 966G, 966G II, 966H, 966K, 966M, 966M XE, 970F, 972G, 972G II, 972H, 972K, 972M, 972M XE, IT38G II
545, 545C, 545D, 555D, 814F, 814F II, 815F, 815F II, 816F, 816F II, 966F, 966F II, 966G, 966G II, 966H, 966K, 966M, 966M XE, 970F, 972G, 972G II, 972H, 972K, 972M, 972M XE, IT38G II
2K0535
NUT
508, 518, 528, 528B, 530B, 613, 613B, 814, 815, 926, 930, 930R, 936, 950, 950B, 950B/950E, 966C, D250B, D250E, D25C, D25D, D300B, D300D, D300E, D30C, D350C, D350E, D35C, D35HP, D400, D40D, G936, IT28
508, 518, 528, 528B, 530B, 613, 613B, 814, 815, 926, 930, 930R, 936, 950, 950B, 950B/950E, 966C, D250B, D250E, D25C, D25D, D300B, D300D, D300E, D30C, D350C, D350E, D35C, D35HP, D400, D40D, G936, IT28
8R0935
NUT-STAKE
545, 545C, 545D, 555D, 814F, 814F II, 815F, 815F II, 816F, 816F II, 966F, 966F II, 970F, R1600, R1600G, R1600H
545, 545C, 545D, 555D, 814F, 814F II, 815F, 815F II, 816F, 816F II, 966F, 966F II, 970F, R1600, R1600G, R1600H
4E3645
NUT-ADJUSTMENT
2470C, 2570C, 2670C, 2864C, 525B, 525C, 533, 535B, 535C, 543, 545, 545C, 553C, 563C, 573C, 586C, 814F, 814F II, 815F, 815F II, 816F, 816F II, 966F, 966F II, 970F, HA770, HA771, HA870, HA871, R1600, R1...
2470C, 2570C, 2670C, 2864C, 525B, 525C, 533, 535B, 535C, 543, 545, 545C, 553C, 563C, 573C, 586C, 814F, 814F II, 815F, 815F II, 816F, 816F II, 966F, 966F II, 970F, HA770, HA771, HA870, HA871, R1600, R1...
9D7989
NUT
69D, 768C, 769C, 769D, 771C, 771D, 772B, 773B, 773D, 773E, 775B, 775D, 775E, 776, 776C, 776D, 777, 777B, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793, 793B, 793C, 793D, 793F, 79...
69D, 768C, 769C, 769D, 771C, 771D, 772B, 773B, 773D, 773E, 775B, 775D, 775E, 776, 776C, 776D, 777, 777B, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793, 793B, 793C, 793D, 793F, 79...
5P5414
NUT
950B
950B
8B9737
NUT
950
950
4K0982
NUT
980
980
4V5103
NUT
980C
980C
5D4243
NUT
768B, 769, 988B
768B, 769, 988B
2K2870
NUT ASSEM.
966C
966C
2Y8738
NUT
966C
966C
2Y8722
NUT
966C
966C
2Y8720
NUT
966C
966C
7X2597
NUT
980C, 980F
980C, 980F
7X2596
NUT-FULL
950B, 966D
950B, 966D
2J8507
NUT
980C, 980F
980C, 980F