Negative Diode Check
Illustration 1 g00825570
Negative Diode Check (9) Stator leads (10) "B-" terminal (11) Stator lead connection
Disconnect all stator leads (9) from the rectifier.
Set the multimeter to the diode scale.
Connect the multimeter leads across one stator lead connection (11) and "B-" terminal (10) .
Record the multimeter reading.
Reverse the multimeter leads.
Record the multimeter reading.Expected Result: One reading is "0L" and the other reading is .4 to .9 volts.Results:OK - One reading is "0L" and the other reading is .4 to .9 volts. The diode is normal. Repeat steps 1 through 6 for the other stator lead connections (11). STOP.NOT OK - Both readings are "00". The diode is shorted. Replace the rectifier. STOP.NOT OK - Both readings are "0L". The diode is open. Replace the rectifier. STOP.Note: The 35 amp alternator has three negative diodes and three stator leads. The remaining alternators have four negative diodes and four stator leads.Positive Diode Check
Illustration 2 g00825571
Positive diode check (9) Stator leads (11) Stator lead connection (12) "B+" terminal
Stator leads (9) remain disconnected from the rectifier.
The multimeter remains on the diode scale.
Connect the multimeter leads across one stator lead connection (11) and "B+" terminal (12) .
Record the multimeter reading.
Reverse the multimeter leads.
Record the multimeter reading.Expected Result: One reading is "0L" and the other reading is .4 to .9 volts.Results:OK - One reading is "0L" and the other reading is .4 to .9 volts. The diode is normal. Repeat steps 1 through 6 for the other stator lead connections (11). STOP.NOT OK - Both readings are "00". The diode is shorted. Replace the rectifier. STOP.NOT OK - Both readings are "0L". The diode is open. Replace the rectifier. STOP.Note: The 35 amp alternator has three positive diodes and three stator leads. The remaining alternators have four positive diodes and four stator leads.Exciter Diode Check
Illustration 3 g00825576
Exciter Diode Check (2) Wire assembly (9) Stator leads (11) Stator lead connection (13) Exciter diode output
Stator leads (9) remain disconnected from the rectifier.
The multimeter remains on the diode scale.
Disconnect wire assembly (2) from the rectifier.
Connect the multimeter leads across one stator lead connection (11) and exciter diode output (13) .
Record the multimeter reading.
Reverse the multimeter leads.
Record the multimeter reading.Expected Result: One reading is "0L" and the other reading is .4 to .9 volts.Results:OK - One reading is "0L" and the other reading is .4 to .9 volts. The diode is normal. Repeat steps 3 through 7 for the other stator lead connections (11). STOP.NOT OK - Both readings are "00". The diode is shorted. Replace the rectifier. STOP.NOT OK - Both readings are "0L". The diode is open. Replace the rectifier. STOP.Note: The 35 amp alternator has three exciter diodes and three stator leads. The remaining alternators have three exciter diodes and four stator leads. If the alternator has four stator leads, do not test the stator lead with the black mark. The stator with the black mark lacks an exciter diode. Ignore the result for that stator lead. See Systems Operation, "Component Description" for more information on the stator
Illustration 1 g00825570
Negative Diode Check (9) Stator leads (10) "B-" terminal (11) Stator lead connection
Disconnect all stator leads (9) from the rectifier.
Set the multimeter to the diode scale.
Connect the multimeter leads across one stator lead connection (11) and "B-" terminal (10) .
Record the multimeter reading.
Reverse the multimeter leads.
Record the multimeter reading.Expected Result: One reading is "0L" and the other reading is .4 to .9 volts.Results:OK - One reading is "0L" and the other reading is .4 to .9 volts. The diode is normal. Repeat steps 1 through 6 for the other stator lead connections (11). STOP.NOT OK - Both readings are "00". The diode is shorted. Replace the rectifier. STOP.NOT OK - Both readings are "0L". The diode is open. Replace the rectifier. STOP.Note: The 35 amp alternator has three negative diodes and three stator leads. The remaining alternators have four negative diodes and four stator leads.Positive Diode Check
Illustration 2 g00825571
Positive diode check (9) Stator leads (11) Stator lead connection (12) "B+" terminal
Stator leads (9) remain disconnected from the rectifier.
The multimeter remains on the diode scale.
Connect the multimeter leads across one stator lead connection (11) and "B+" terminal (12) .
Record the multimeter reading.
Reverse the multimeter leads.
Record the multimeter reading.Expected Result: One reading is "0L" and the other reading is .4 to .9 volts.Results:OK - One reading is "0L" and the other reading is .4 to .9 volts. The diode is normal. Repeat steps 1 through 6 for the other stator lead connections (11). STOP.NOT OK - Both readings are "00". The diode is shorted. Replace the rectifier. STOP.NOT OK - Both readings are "0L". The diode is open. Replace the rectifier. STOP.Note: The 35 amp alternator has three positive diodes and three stator leads. The remaining alternators have four positive diodes and four stator leads.Exciter Diode Check
Illustration 3 g00825576
Exciter Diode Check (2) Wire assembly (9) Stator leads (11) Stator lead connection (13) Exciter diode output
Stator leads (9) remain disconnected from the rectifier.
The multimeter remains on the diode scale.
Disconnect wire assembly (2) from the rectifier.
Connect the multimeter leads across one stator lead connection (11) and exciter diode output (13) .
Record the multimeter reading.
Reverse the multimeter leads.
Record the multimeter reading.Expected Result: One reading is "0L" and the other reading is .4 to .9 volts.Results:OK - One reading is "0L" and the other reading is .4 to .9 volts. The diode is normal. Repeat steps 3 through 7 for the other stator lead connections (11). STOP.NOT OK - Both readings are "00". The diode is shorted. Replace the rectifier. STOP.NOT OK - Both readings are "0L". The diode is open. Replace the rectifier. STOP.Note: The 35 amp alternator has three exciter diodes and three stator leads. The remaining alternators have three exciter diodes and four stator leads. If the alternator has four stator leads, do not test the stator lead with the black mark. The stator with the black mark lacks an exciter diode. Ignore the result for that stator lead. See Systems Operation, "Component Description" for more information on the stator
Caterpillar SIS machinery equipment:
Caterpillar SIS
902 Compact Wheel Loader 7ES00001-UP (MACHINE) POWERED BY 3024 Engine »
148-7059
OPERATOR AR-OPEN ROPS
906 Compact Wheel Loader 6ZS00001-UP (MACHINE) POWERED BY 3034 Engine »
148-7059
OPERATOR AR-OPEN ROPS
906 Wheel Loader MER00001-UP (MACHINE) POWERED BY 3044C Engine »
148-7059
OPERATOR AR-OPEN ROPS
Parts operator Caterpillar catalog:
1787848
OPERATOR AR-OPEN ROPS
902, 906, 908
902, 906, 908
1787847
OPERATOR AR-OPEN ROPS
902, 906, 908
902, 906, 908
1487055
OPERATOR AR-OPEN ROPS
902, 906
902, 906
1553164
OPERATOR AR-ENCLOSED ROPS
902, 906
902, 906
1553166
OPERATOR AR-ENCLOSED ROPS
902, 906
902, 906
1380208
OPERATOR AR-ENCLOSED ROPS
902, 906
902, 906
1380201
OPERATOR AR-ENCLOSED ROPS
902, 906
902, 906
1380205
OPERATOR AR-ENCLOSED ROPS
902, 906
902, 906
1787844
OPERATOR AR-ENCLOSED ROPS
902, 906, 908
902, 906, 908
1787845
OPERATOR AR-ENCLOSED ROPS
902, 906, 908
902, 906, 908
1380199
OPERATOR AR-OPEN ROPS
902, 906
902, 906
1487062
OPERATOR AR-OPEN ROPS
902, 906
902, 906
7I3881
OPERATOR AR
950F II
950F II
1732483
OPERATOR AR-OPEN ROPS
966G, 972G
966G, 972G
1397177
OPERATOR AR
318B
318B
1192083
OPERATOR AR
IT38F
IT38F
1610872
OPERATOR AR
30/30
30/30
1224595
OPERATOR AR
950F II
950F II
1442620
OPERATOR AR
836G
836G
1732139
OPERATOR AR
980G II
980G II