1880208 PAN-OIL Caterpillar parts
385B, 5090B
Rating:
Alternative (cross code) number:
CA1880208
188-0208
1880208
CA1880208
188-0208
1880208
Weight: 41 pounds 18 kg.
EXCAVATOR, FRONT SHOVEL,
Information:
Illustration 1 g02350520
The "Negative Flow Control 1 (NFC 1)" pressure sensor is located in the pump compartment that is in the center of the machine.
Illustration 2 g02040556
Schematic of the "NFC 1 Pressure" SensorThis diagnostic code is associated with the "NFC 1 Pressure" Sensor. This diagnostic code is recorded when the Machine ECM reads the frequency of the signal and the frequency is not within an expected range. Note: Before performing the following procedure, ensure that the diagnostic code for this procedure is active.The possible causes of this diagnostic code are listed below:
The sensor has failed.
Intermittent connections or poor connections Test Step 1. CHECK THE +8 VDC SUPPLY VOLTAGE.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector from the sensor.
Turn the disconnect switch and the key start switch to the ON position.
At the machine harness connector for the sensor, measure the voltage (VDC) between contact 1 (wire J850-WH) and contact 2 (wire 235-BK).
At the machine harness connector for the sensor, measure the voltage (VDC) between contact 1 (wire J850-WH) and frame ground. Expected Result:The voltage is 8 0.5 VDC for both measurements. Results:
OK - The voltage is 8 0.5 VDC for both measurements. The voltage is correct. Proceed to Test Step 2.
NOT OK - The voltage is NOT 8 0.5 VDC for both measurements. The voltage is not correct. The Machine ECM has failed or the harness has failed. Repair: A failure of the ECM is unlikely. Verify the harness. If the harness is correct, replace the Machine ECM. STOPTest Step 2. VERIFY THE GROUND OF THE SENSOR.
At the machine harness connector of the sensor, place a jumper between contact 2 (wire 235-BK) and frame ground.
At the machine harness connector J1, measure the resistance between the contact J1-14 (wire 235-BK) and frame ground.
At the machine harness connector J1, measure the resistance between the contact J1-2 (wire 235-BK) and frame ground. Expected Result:The resistance is less than 5 ohms for each circuit. Results:
OK - The resistance is less than 5 ohms. The circuit resistance is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5 ohms. The circuit resistance is not correct. The harness is open. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK THE SENSOR SIGNAL CIRCUIT.
Remove the jumper that
Caterpillar parts catalog:
Parts pan Caterpillar catalog:
1729944
PAN GP-OIL
385B, 5090B
385B, 5090B
2191494
PAN GP-OIL
385B, 5090B
385B, 5090B
1880209
PAN-OIL
385B, 5090B
385B, 5090B
1889296
PAN-OIL
385B, 5090B
385B, 5090B
2191495
PAN-OIL
385B, 5090B
385B, 5090B
2191496
PAN-OIL
385B, 5090B
385B, 5090B
7N9802
PAN-FRONT OIL
5110B, D10N, D10R, D10T, D9L
5110B, D10N, D10R, D10T, D9L
2202648
PAN AS-OIL
5110B
5110B
1384047
PAN AS-OIL
5110B
5110B
1295423
PAN-OIL
5110B
5110B
1295424
PAN-OIL
5110B
5110B
1378251
PAN-OIL
5130B
5130B
1102309
PAN-OIL
AP-800, CS-431B
AP-800, CS-431B
4559175
PAN GP-OIL
AD55
AD55
2191496
PAN-OIL
385B, 5090B
385B, 5090B
2191495
PAN-OIL
385B, 5090B
385B, 5090B
1889296
PAN-OIL
385B, 5090B
385B, 5090B
1880209
PAN-OIL
385B, 5090B
385B, 5090B