0385791 PANEL G-SIDE Caterpillar parts
Rating:
Alternative (cross code) number:
CA0385791
038-5791
0385791
CA0385791
038-5791
0385791
Weight: 38 pounds 17 kg.
Information:
Illustration 1 g00878460
ET Configuration Screen
Select "Configuration" from the Service menu on the ET screen.
Highlight "Product ID". See Illustration 1.
Illustration 2 g00879384
Change Parameter Value Screen
Select the "Change" button at the bottom of the Configuration screen. The "Change Parameter Value" field appears.
Illustration 3 g00878461
Caterpillar World Manufacturing Code
Enter the "Product ID" of the machine in the field for "New Value". See Illustration 3. The "Product ID" is the last eight characters of the Caterpillar Product Identification Number (PIN).
Select "OK".
Setting the Time and Date
Select "ECM Date/Time" from the Service menu on the ET screen. The screen for the "ECM Date/Time" appears.
Illustration 4 g00879419
Screen for the Date and Time
Click the "Change" button. The fields for the date and the time appear. See Illustration 4.
Enter the correct time and the correct date and select "OK".
Bypassing the Security SystemThe start time and the stop time of the MSS must be configured for deactivation in order to deactivate the MSS for a period of time.
Insert a key with Master Access Level in the key start switch and turn to the ON position.
Select "Configuration" from the Service menu on the ET screen. The configuration screen appears.
Highlight the "Security System Bypass Start Time" for the day that is desired for bypassing the MSS.
Select the "Change" button at the bottom of the page. The "Change Parameter Value" field appears.
Enter the desired start time for the bypass in the "New Value" field.All times are based on a 24 hour clock: for a start time of 6:00 AM, enter 6:00. For a start time of 6:00 PM, enter 18:00. Include the colon that is used in the setting for the time.
Select "OK". The configuration screen appears.
Highlight the "Security System Bypass Stop Time" in order to enter the time that is needed to bypass the MSS.
Select the "Change" button at the bottom of the screen. The "Change Parameter Value" field appears.
Enter the time to stop for the bypass in the "New Value" field. Then select "OK".Note: If you desire to arm the system 24 hours a day, set the time to start and stop for the bypass to the same time.Note: If you desire to disarm the system for 24 hours, set the time to start to 00:00 and the time to stop to 23:59.
Parts panel Caterpillar catalog:
0385573
PANEL G TOP
Caterpillar
Caterpillar
0385571
PANEL G-TOP
Caterpillar
Caterpillar
0385483
PANEL G-INSTR
Caterpillar
Caterpillar
0385272
PANEL G-TOP
Caterpillar
Caterpillar
0385093
PANEL G-TOP
Caterpillar
Caterpillar
0385083
PANEL G-TOP
Caterpillar
Caterpillar
0385863
PANEL A
Caterpillar
Caterpillar
0385862
PANEL G-SIDE
Caterpillar
Caterpillar
0385861
PANEL G-SIDE
Caterpillar
Caterpillar
0385858
PANEL A
Caterpillar
Caterpillar
0385857
PANEL A
Caterpillar
Caterpillar
0385847
PANEL G-CONT
Caterpillar
Caterpillar