Illustration 8 g01199794
Typical example of the "SERVICE" menu for the monitor
Press down key (6) in order to highlight the menu option "CALIBRATIONS".
When the "CALIBRATIONS" menu is highlighted, press the OK key (8) .
Illustration 9 g01861509
Press down key (6) in order to highlight the menu option "BM DOWN REGEN PRV".
When the "BM DOWN REGEN PRV" option is highlighted, press the OK key (8) .
Illustration 10 g01861497
The monitor will begin to communicate with the ECM. This may take a few moments. When the communication link is established, the monitor will display the calibration screen.
Illustration 11 g01200825
(L) Lower limit (U) Upper limit (C) Current Value (S) "STEP NUMBER" and "STEP NAME"
After the OK key is pressed, the "CALIBRATION TITLE" will appear. The "CALIBRATION TITLE" screen allows the upper limitation and the lower limitation to be set. Refer to Illustration 11.Note: The title of the calibration and the name of the step will change in accordance to the procedure that is being performed. "CALIBRATION TITLE" and "STEP NAME" are used in this document as an example.Note: In the "CALIBRATION TITLE" screen, "STEP No" is displayed in blue. The "OPERATION GUIDANCE" will be displayed in green.
Illustration 12 g01861503
Press the OK key (8) in order to start the calibration.Note: The "HYD OIL TEMP / ENGINE SPEED" screens are available during the process of calibration by pressing the up key (1) or the down key (6) .
Illustration 13 g01861502
Hold the joystick for the boom at the full BOOM DOWN position. Press the OK key (8) .
Illustration 14 g01861507
Press the right key (2) in order to increase the value. Press the left key (5) in order to decrease the value. Adjust the value until the gauge pressure is within the specification.
When the value is within the specification, press the OK key (8) .
Illustration 15 g01861499
After the OK key is pressed the monitor will automatically continue with the tuning of the next pressure value. Hold the joystick for the boom at the full BOOM DOWN position. Press the OK key (8) .
Illustration 16 g01861501
Press the right key (2) in order to increase the value. Press the left key (5) in order to decrease the value. Adjust the value until the gauge pressure is within the specification.
When the value is within the specification, press the OK key (8) in order to proceed to the next screen.
Illustration 17 g01861508
The calibration is complete. Press the cancel key (7) in order to exit the process of calibration.
Illustration 18 g01861498
The "ERROR ID" screen will be displayed on the monitor if an error occurs. The process of calibration will not be saved and the process must be restarted.
Parts panel Caterpillar catalog:
1152517
PANEL-
Caterpillar
Caterpillar
1152514
PANEL-
Caterpillar
Caterpillar
1150189
PANEL
Caterpillar
Caterpillar
1146649
PANEL AR-CONT
Caterpillar
Caterpillar
1146648
PANEL AR-CONT
Caterpillar
Caterpillar
1143122
PANEL GP-
Caterpillar
Caterpillar
1171139
PANEL AS-
Caterpillar
Caterpillar
1168546
PANEL GP-
Caterpillar
Caterpillar
1167688
PANEL-LH INST
Caterpillar
Caterpillar
1166864
PANEL-
Caterpillar
Caterpillar
1160199
PANEL GP-
Caterpillar
Caterpillar
1159825
PANEL AS
Caterpillar
Caterpillar