2311659 PANEL GP-CIRCUIT BREAKER Caterpillar parts
322C, 325C, 330C, 330C L
Rating:
Alternative (cross code) number:
CA2311659
231-1659
2311659
CA2311659
231-1659
2311659
EXCAVATOR, MOBILE HYD POWER UNIT,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Global Parts Distributors - 06-09 FUSION (2311659)
Global Parts 2311659 || Fits - 06-09 FUSION || Blower Motor || Meets or exceeds OEM Specifications
Global Parts 2311659 || Fits - 06-09 FUSION || Blower Motor || Meets or exceeds OEM Specifications
Global Parts Distributors - 06-09 FUSION (2311659)
Global Parts 2311659 || Fits - 06-09 FUSION || Blower Motor || Meets or exceeds OEM Specifications
Global Parts 2311659 || Fits - 06-09 FUSION || Blower Motor || Meets or exceeds OEM Specifications
This part in 2 request:
Show.
This information for suppliers only!
2023-03-19
2023-03-07
Compatible equipment models: 2311659:
Information:
Test Procedure
Note: The steps in the procedure correlate with the steps under the test specifications according to your specific part number.The contamination level of the hydraulic oil in the test bench should be ISO 16/13 or better. The oil in the test bench should be one of the following.
SAE 10W at 50 °C (122 °F) or
Mobil DTE-11 at 46 °C (115 °F)
Illustration 10 g01378800
Pump Characteristics
(F) Discharge Flow
(P) Discharge Pressure
Before rotating the pump, be sure that the Adjustment screw for the pressure relief valve (62) is completely opened (turned completely counter-clockwise). Start rotating the pump according to the RPM in Step 1 of the"Test Procedure". Adjust 231-1286 Pressure Relief Valve (61) to the charge pressure in Step 1 of the Test Specifications by turning the Adjustment screw for the pressure relief valve (62), if necessary. Listen for abnormal noise and verify flow from the pump. Be sure that all connections are secure and not leaking. Check for leaking shaft seals and control valve connections.
Slowly increase the input RPM to the value in Step 2 of the Test Specifications. Adjust 231-1286 Pressure Relief Valve (61) to the charge pressure in Step 2 of the Test Specifications, if necessary. The pump may not be feasible if the actual flow is less than the value in Step 2 of the Test Specifications. The pump should be disassembled and inspected.
Increase the pump discharge pressure to the value in Step 3 of the Test Specifications. Adjust 231-1286 Pressure Relief Valve (61) to the charge pressure in Step 3 of the Test Specifications, if necessary. Compare the actual case drain value with the case drain value in Step 3 of the Test Specifications. This value is an indication of the pump efficiency. The pump may not be feasible if the case drain is more than the value in Step 3 of the Test Specifications. The pump should be disassembled and inspected.Note: There will be a substantial amount of residual oil exiting 5P-2974 Connector (59), especially when the high-pressure cut is reached during Step 4 of the Test Procedure. Direct oil accordingly with hose secured.
Increase the pump discharge pressure to the value in Step 4 of the Test Specifications. Adjust 231-1286 Pressure Relief Valve (61) to the charge pressure in Step 4 of the Test Specifications, if necessary. Turn the adjustment screw for the high pressure cut (49) until the actual high-pressure cut value is equal to the value in Step 4 of the Test Specifications. Pump discharge flow should be zero when the high-pressure cut is reached.
Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact skin.
Reduce RPM and all pressures to zero. Remove the component from the test bench. Drain the oil from the pump. Cap and plug all ports.Test Specifications
Table 3
Part Number Pump Rotation Step Input Speed Discharge Pressure kPa (psi) Discharge Flow lpm (gpm) Charge Pressure
( 231-1286 Pressure Relief Valve setting)
kPa (psi) Max. Case Drain Flow lpm (gpm)
339-0926 CCW 1 500 0 22 (5.8)
Note: The steps in the procedure correlate with the steps under the test specifications according to your specific part number.The contamination level of the hydraulic oil in the test bench should be ISO 16/13 or better. The oil in the test bench should be one of the following.
SAE 10W at 50 °C (122 °F) or
Mobil DTE-11 at 46 °C (115 °F)
Illustration 10 g01378800
Pump Characteristics
(F) Discharge Flow
(P) Discharge Pressure
Before rotating the pump, be sure that the Adjustment screw for the pressure relief valve (62) is completely opened (turned completely counter-clockwise). Start rotating the pump according to the RPM in Step 1 of the"Test Procedure". Adjust 231-1286 Pressure Relief Valve (61) to the charge pressure in Step 1 of the Test Specifications by turning the Adjustment screw for the pressure relief valve (62), if necessary. Listen for abnormal noise and verify flow from the pump. Be sure that all connections are secure and not leaking. Check for leaking shaft seals and control valve connections.
Slowly increase the input RPM to the value in Step 2 of the Test Specifications. Adjust 231-1286 Pressure Relief Valve (61) to the charge pressure in Step 2 of the Test Specifications, if necessary. The pump may not be feasible if the actual flow is less than the value in Step 2 of the Test Specifications. The pump should be disassembled and inspected.
Increase the pump discharge pressure to the value in Step 3 of the Test Specifications. Adjust 231-1286 Pressure Relief Valve (61) to the charge pressure in Step 3 of the Test Specifications, if necessary. Compare the actual case drain value with the case drain value in Step 3 of the Test Specifications. This value is an indication of the pump efficiency. The pump may not be feasible if the case drain is more than the value in Step 3 of the Test Specifications. The pump should be disassembled and inspected.Note: There will be a substantial amount of residual oil exiting 5P-2974 Connector (59), especially when the high-pressure cut is reached during Step 4 of the Test Procedure. Direct oil accordingly with hose secured.
Increase the pump discharge pressure to the value in Step 4 of the Test Specifications. Adjust 231-1286 Pressure Relief Valve (61) to the charge pressure in Step 4 of the Test Specifications, if necessary. Turn the adjustment screw for the high pressure cut (49) until the actual high-pressure cut value is equal to the value in Step 4 of the Test Specifications. Pump discharge flow should be zero when the high-pressure cut is reached.
Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact skin.
Reduce RPM and all pressures to zero. Remove the component from the test bench. Drain the oil from the pump. Cap and plug all ports.Test Specifications
Table 3
Part Number Pump Rotation Step Input Speed Discharge Pressure kPa (psi) Discharge Flow lpm (gpm) Charge Pressure
( 231-1286 Pressure Relief Valve setting)
kPa (psi) Max. Case Drain Flow lpm (gpm)
339-0926 CCW 1 500 0 22 (5.8)
Caterpillar SIS machinery equipment:
Caterpillar SIS
330C Excavator MSD00001-UP (MACHINE) POWERED BY C-9 Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
330C Excavator MSD00001-UP (MACHINE) POWERED BY C-9 Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
330C & 330C L Excavators GKX00001-UP (MACHINE) POWERED BY C-9 Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
330C & 330C L Excavators GKX00001-UP (MACHINE) POWERED BY C-9 Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
325C & 325C L Excavators AMH00001-UP (MACHINE) POWERED BY 3126B Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
325C & 325C L Excavators AMH00001-UP (MACHINE) POWERED BY 3126B Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
325C & 325C L Excavators AMH00001-UP (MACHINE) POWERED BY 3126B Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
325C & 325C L Excavators BKW00001-UP (MACHINE) POWERED BY 3126B Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
325C & 325C L Excavators BKW00001-UP (MACHINE) POWERED BY 3126B Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
325C & 325C L Excavators BKW00001-UP (MACHINE) POWERED BY 3126B Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
330C & 330C L Excavators JAB00001-UP (MACHINE) POWERED BY C-9 Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
330C & 330C L Excavators JAB00001-UP (MACHINE) POWERED BY C-9 Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
330C L Excavator CYA00001-UP (MACHINE) POWERED BY C-9 Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
330C L Excavator CYA00001-UP (MACHINE) POWERED BY C-9 Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
322C & 322C L Excavators DAA00001-UP (MACHINE) POWERED BY 3126 Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
322C & 322C L Excavators DAA00001-UP (MACHINE) POWERED BY 3126 Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
322C & 322C L Excavators DAA00001-UP (MACHINE) POWERED BY 3126 Engine »
231-1659
PANEL GP-CIRCUIT BREAKER
Caterpillar parts catalog:
Parts panel Caterpillar catalog:
1636701
PANEL AS-CONTROL
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 320C L, 322C, 322C FM, 325C, 325C FM, 330C, 330C FM, 330C L, 330C MH
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 320C L, 322C, 322C FM, 325C, 325C FM, 330C, 330C FM, 330C L, 330C MH
1573210
PANEL AS-CONTROL
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 320C L, 322C, 325C, 330C, 330C L
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 320C L, 322C, 325C, 330C, 330C L
1961636
PANEL
308C, 314C, 321C, 325C
308C, 314C, 321C, 325C
1961635
PANEL
308C, 314C, 321C, 325C
308C, 314C, 321C, 325C
2299029
PANEL
308C, 314C, 321C, 325C
308C, 314C, 321C, 325C
2242934
PANEL
312C L, 315C, 318C, 320C, 322C, 325C, 330C, 330C L
312C L, 315C, 318C, 320C, 322C, 325C, 330C, 330C L
2179355
PANEL-SWITCH
321C, 325C
321C, 325C
2243579
PANEL AS
325C
325C
2382374
PANEL GP
325C
325C
2086414
PANEL AS
325C
325C
2318394
PANEL AS
325C
325C
2581971
PANEL AS
325C
325C
1807386
PANEL GP-CONTROL
3508B, 3508C, 3512B, 3512C, 3516B
3508B, 3508C, 3512B, 3512C, 3516B
3171012
PANEL GP-CONTROL
G3516C, G3520C
G3516C, G3520C
2760149
PANEL GP-CIRCUIT BREAKER
725, 730
725, 730
2950996
PANEL GP-INSTRUMENT
AP-600D, AP-655D
AP-600D, AP-655D
3858629
PANEL GP-SOUND SUPPRESSION
390F L, 770G, 770G OEM, 772G, 772G OEM, 824K, 825K, 826K, C15, C18
390F L, 770G, 770G OEM, 772G, 772G OEM, 824K, 825K, 826K, C15, C18
2510043
PANEL GP-POWER SUPPLY
UPS 250, UPS 600G
UPS 250, UPS 600G
2369293
PANEL GP-SOUND SUPPRESSION
385C, 385C FS, 385C L, 385C L MH
385C, 385C FS, 385C L, 385C L MH
3266194
PANEL GP-CIRCUIT BREAKER
AP-600D, AP-655D, BG600D, BG655D
AP-600D, AP-655D, BG600D, BG655D
1116809
PANEL GP-SOUND SUPPRESSION
RM-350B, SM-350
RM-350B, SM-350
2558888
PANEL GP-ELECTRONIC
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C175-16, C175-20, C32, G3512E, G3516, G3516B
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C175-16, C175-20, C32, G3512E, G3516, G3516B
2712779
PANEL GP-HOOD
824H, 825H, 826H, 980H
824H, 825H, 826H, 980H