Illustration 1 g01003929
Typical example
Crank the engine with the throttle lever in the CLOSED position until the engine starts.Note: If necessary, loosen the union nuts (1) on the fuel injection lines at the connection with the fuel injector until fuel is evident. Stop cranking the engine. Tighten the union nuts (1) to a torque of 30 N m (22 lb ft).
Start the engine and run the engine at idle for 1 minute.
Do not crank the engine continuously for more than 30 seconds. Allow the starting motor to cool for two minutes before cranking the engine again.
Cycle the throttle lever from the low idle position to the high idle position three times. The cycle time for the throttle lever is one second to 6 seconds for one complete cycle.Note: In order to purge air from the fuel injection pump on engines with a fixed throttle, the engine should be run at full load for 30 seconds. The load should then be decreased until the engine is at high idle. The procedure should be repeated three times. The procedure will assist in removing trapped air from the fuel injection pump.
Check for leaks in the fuel system.Alternative Fuel System Prime Procedure
Ensure that the correct fuel priming procedure is carried out. Failure to carry out the correct procedure may result in damage to the fuel injection pump and other fuel system components.
To purge air from the fuel system, there is a new alternative fuel priming procedure. The following procedure should be carried out before the engine is started.
Turn the keyswitch to the RUN position. Leave the keyswitch in the RUN position for 3 minutes.
Do not crank the engine continuously for more than 30 seconds. Allow the starting motor to cool for two minutes before cranking the engine again.
Crank the engine with the throttle lever in the CLOSED position until the engine starts.Note: If necessary, loosen the union nuts on the fuel injection lines at the connection with the fuel injector until fuel is evident. Stop cranking the engine. Tighten the union nuts to a torque of 30 N m (22 lb ft).
Once the engine has started, operate the engine at low idle for 1 minute.
Turn the keyswitch to the OFF position to stop the engine. Wait for 30 seconds.
Start the engine. The fuel system will now be primed and ready for operation.

Caterpillar parts catalog:

Caterpillar parts catalog
UPS1000S, UPS1200S, ES12F, Uninterruptible Power Supply CZE00001-UP


Parts panel Caterpillar catalog:

2364957 PANEL AR-CONTROL
3512, 3512B, 3512C, 3516, 3516B, 3516C, C27, C32, ES12F, UPS 250
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.