3601976 PANEL AS Caterpillar parts
735B, 740B
Rating:
Alternative (cross code) number:
CA3601976
360-1976
3601976
CA3601976
360-1976
3601976
Weight: 12 pounds 5 kg.
ARTICULATED TRUCK, EJECTOR TRUCK,
Information:
Which Generate This Code:This diagnostic code is associated with the calibration of the lift valves. The calibration parameters have been corrupted.This error usually occurs after a software update.System Response:When this diagnostic code occurs, the calibration values will be reset to defaults.Test Step 1. CALIBRATE THE VALVE
Start the procedure for the valve calibration. Refer to Systems Operation, Troubleshooting, Testing and Adjusting, "Bank valve - Calibrate"Expected Result:Calibration causes the diagnostic code to become inactive.Results:
OK - Calibration causes the diagnostic code to become inactive.Repair: Return the machine to normal operation.STOP
NOT OK - Calibration has not caused the diagnostic code to become inactive. Perform the calibration again. Proceed to Test Step 2.Test Step 2. RECALIBRATE THE VALVE
Restart the procedure for the valve calibration. Refer to Systems Operation, Troubleshooting, Testing and Adjusting, "Bank valve - Calibrate"Expected Result:Recalibration causes the diagnostic code to become inactive.Results:
OK - Calibration causes the diagnostic code to become inactive.Repair: Return the machine to normal operation.STOP
NOT OK - If the diagnostic code is still active after completing another calibration, proceed to Test Step 3.Test Step 3. REFLASH THE FIRMWARE
Reflash the firmware for the Display. Refer to Systems Operation, Testing and Adjusting, Troubleshooting, "Module - Flash Program"Results:
OK - STOP
Start the procedure for the valve calibration. Refer to Systems Operation, Troubleshooting, Testing and Adjusting, "Bank valve - Calibrate"Expected Result:Calibration causes the diagnostic code to become inactive.Results:
OK - Calibration causes the diagnostic code to become inactive.Repair: Return the machine to normal operation.STOP
NOT OK - Calibration has not caused the diagnostic code to become inactive. Perform the calibration again. Proceed to Test Step 2.Test Step 2. RECALIBRATE THE VALVE
Restart the procedure for the valve calibration. Refer to Systems Operation, Troubleshooting, Testing and Adjusting, "Bank valve - Calibrate"Expected Result:Recalibration causes the diagnostic code to become inactive.Results:
OK - Calibration causes the diagnostic code to become inactive.Repair: Return the machine to normal operation.STOP
NOT OK - If the diagnostic code is still active after completing another calibration, proceed to Test Step 3.Test Step 3. REFLASH THE FIRMWARE
Reflash the firmware for the Display. Refer to Systems Operation, Testing and Adjusting, Troubleshooting, "Module - Flash Program"Results:
OK - STOP
Caterpillar parts catalog:
Parts panel Caterpillar catalog:
3407389
PANEL AS-INSTRUMENT
725C, 730C, 735B, 740B
725C, 730C, 735B, 740B
3454134
PANEL AS
725C, 730C, 735B, 740B
725C, 730C, 735B, 740B
3514733
PANEL AS
735B, 740B
735B, 740B
3514734
PANEL AS
735B, 740B
735B, 740B
3514735
PANEL AS
735B, 740B
735B, 740B
3845267
PANEL AS
735B, 740B
735B, 740B
3845268
PANEL AS
735B, 740B
735B, 740B
3845269
PANEL AS
735B, 740B
735B, 740B
3601977
PANEL AS
735B, 740B
735B, 740B
3540749
PANEL AS
725C, 730C, 735B, 740B
725C, 730C, 735B, 740B
3311125
PANEL
725C, 730C, 735B, 740B
725C, 730C, 735B, 740B
4517330
PANEL GP-CAB
735B, 740B
735B, 740B
3845269
PANEL AS
735B, 740B
735B, 740B
3845268
PANEL AS
735B, 740B
735B, 740B
3845267
PANEL AS
735B, 740B
735B, 740B
3514735
PANEL AS
735B, 740B
735B, 740B
3514734
PANEL AS
735B, 740B
735B, 740B
3514733
PANEL AS
735B, 740B
735B, 740B
3507979
PANEL AS
793F-XQ
793F-XQ
3507974
PANEL AS
793F-XQ
793F-XQ
4517330
PANEL GP-CAB
735B, 740B
735B, 740B
3311125
PANEL
725C, 730C, 735B, 740B
725C, 730C, 735B, 740B
3540749
PANEL AS
725C, 730C, 735B, 740B
725C, 730C, 735B, 740B
3601977
PANEL AS
735B, 740B
735B, 740B