Illustration 1 g01131950
Schematic of the Radiator Fan Speed Control SolenoidThis diagnostic code is associated with the Radiator Fan Speed Control Solenoid. The FMI 03 means that the ECM has determined that the voltage of the solenoid circuit is above normal. The possible causes of the diagnostic code are listed:
The solenoid has failed.
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0291 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The diagnostic code of CID 0291 FMI 03 will be logged in the internal memory of the Machine ECM.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J2-24 (wire E998-YL) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-24 (E998-YL) and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness. Stop.Test Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 0291 FMI 03 is active.Expected Result:The CID 0291 FMI 03 is active.Results:
YES - The CID 0291 FMI 03 is active. The problem has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
NO - The CID 0291 FMI 03 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation. Stop.
Caterpillar parts catalog:
Parts panel Caterpillar catalog:
3889896
PANEL GP-CIRCUIT BREAKER
Caterpillar
Caterpillar
3883214
PANEL AS
Caterpillar
Caterpillar
3883213
PANEL AS
Caterpillar
Caterpillar
3883211
PANEL GP-FENDER
Caterpillar
Caterpillar
3877063
PANEL GP-INSTRUMENT
Caterpillar
Caterpillar
3749904
PANEL GP-SOUND SUPPRESSION
Caterpillar
Caterpillar
4205803
PANEL AS
Caterpillar
Caterpillar
4205801
PANEL AS
Caterpillar
Caterpillar
4156741
PANEL AS-SOUND SUPPRESSION
Caterpillar
Caterpillar
4151130
PANEL GP-CIRCUIT BREAKER
Caterpillar
Caterpillar
3953417
PANEL
Caterpillar
Caterpillar
3950715
PANEL GP-FENDER
Caterpillar
Caterpillar