Information:
Illustration 4 g03096802
Feedback Cabinet
The feedback cabinet has the same dimensions at the 400 kVA cabinet that is shown in Illustration 4.Cabinet Position in Room
To ensure correct ventilation, do not place anything on top of the UPS cabinet. Leave 1 m (3 ft) of free space in front of the UPS in order to allow the door to be opened. The cabinet rests on four cylindrical feet that are 60 mm (2.3 inch) in diameter. The cabinet feet are positioned at the four corners of the cabinet. Six feet are used for the 500 kVA UPS.The UPS can operate correctly with the back of the unit placed against a wall, however, space may be provided to allow for maintenance purposes. The distance between the bottom panel and the floor must be less than 10 mm (0.4 inch).Note: Abnormal temperature rise may occur if 500 mm (19.7 inch) or more of free space is not maintained above the UPS.UPS Cabinet
Illustration 5 g02410979
Static Switch Cabinet (SSC)
Illustration 6 g02411102
Lay out example for an SSC with two parallel UPS units (1) Auxiliary cabinet 2 (2) Battery cabinet 2 (3) UPS 2 cabinet (4) Auxiliary cabinet 1 (5) Battery cabinet 1 (6) UPS 1 cabinet (7) SSCExternal Bypass Cabinets
Illustration 7 g02411359
Lay out example for External Bypass Cabinets (10) UPS 1 cabinet (11) UPS 2 cabinet (12) UPS 3 cabinet (13) External bypass cabinetBattery/Auxiliary Cabinets
Illustration 8 g02413059
Lay out example for two battery cabinets with one UPS unit (14) Battery cabinet 1 (15) Battery cabinet 2 (16) UPS cabinet
Illustration 9 g02413062
Example for two battery cabinets, two auxiliary cabinets, two parallel UPS units, and an SSC (17) Auxiliary cabinet 2 (18) Battery cabinet 2 (19) UPS 2 cabinet (20) Auxiliary cabinet 1 (21) Battery cabinet 1 (22) UPS 1 cabinet (23) SSCVentilation
The optimum operating temperature range is 20° C (68° F) to 25° C (77° F). An operating temperature of 35° C (95° F) is possible, however battery life will be greatly reduced. Size the ventilation system taking into account the values in the table below.
Illustration 10 g02413118
Table 9
UPS cabinets    
Power rating in kVA     160     200     250     300     400     500    
Air flow (in m3/h)     6000     6000     6000     6000     6000     8300    
Heat losses to be evacuated at Pn     kW     10.5     13.5     14.9     18.6     22.6     27.2    
Cal./s 2511     3238     3554     4449     5395     6501    
Table 10
SSC Units    
Power rating in kVA     800     1200     2000     2000 light    
Air flow (in m3/h)     1000     Natural     Natural     Natural    
Heat losses to be evacuated at Pn     kW     3.7     < 1     < 1.5     < 1.5    
Cal./s 884     < 240     < 360     < 360    
Cat SIS web machinery list:
Parts panel Caterpillar catalog:
4578570
PANEL AS
Caterpillar
Caterpillar
4578569
PANEL AS
Caterpillar
Caterpillar
4578556
PANEL AS
Caterpillar
Caterpillar
4578546
PANEL AS
Caterpillar
Caterpillar
4540240
PANEL GP-SIDE
Caterpillar
Caterpillar
4540238
PANEL AS
Caterpillar
Caterpillar
4703459
PANEL AS
Caterpillar
Caterpillar
4703458
PANEL AS
Caterpillar
Caterpillar
4703457
PANEL AS
Caterpillar
Caterpillar
4703456
PANEL AS
Caterpillar
Caterpillar
4656607
PANEL GP-SIDE
Caterpillar
Caterpillar
4656600
PANEL GP-SIDE
Caterpillar
Caterpillar