6G6624 PANEL Caterpillar parts
120G, 130G, 16G
Rating:
Alternative (cross code) number:
CA6G6624
6G-6624
6G6624
CA6G6624
6G-6624
6G6624
Weight: 0.40 pounds 0 kg.
MOTOR GRADER,
Information:
Lightbar Power Up
Observe the lightbars during start-up and make sure that the lightbars work correctly.To perform the light bar start-up check:
To turn on the system power, press the "Power" key on the control box.
Immediately observe the pattern of the lightbar LEDs.The LEDs flash in the sequence described in Table 1.
Table 1
LEDs on the Lightbar Flash
Left Bottom to top
Center (horizontal) Left to right
Right Top to bottom
All Twice, simultaneously Table 2 describes the problems that may occur when powering up the internal lightbars.
Table 2
Problem Action
Lightbars do not illuminate Refer to the Section "Control Box Power Up" to check that the control box has started successfully.
or
Refer to the Section System Preparation - Lightbar Brightness to check that the lightbar brightness is not set too low. Table 3 describes the problems that may occur when powering up the external lightbars.
Table 3
Problem Action
Lightbars do not illuminate Refer to the section "Control Box Power Up" to check that the control box has started successfully.
or
Refer to the Section System Preparation - Lightbar Brightness to check that the lightbar brightness is not set too low.
or
Check the system harness between the control box and the lightbars.
Lightbars flash in the wrong sequence The lightbars have probably been installed incorrectly. Consult the site supervisor. Control Box Power Up
Observe the control box after the system has powered up.A guidance screen should be visible, and softkeys, and optional text items (if configured).If the machine has one or more 3D sensors installed and configured, the following items appear:
A plan view guidance screen
The correct machine icon for the machine type
A site plan, if the system has a site plan file
A design or map, if one was loaded when the system was last powered down.The problems in Table 4 may occur when the control box and the system are powered up.
Table 4
Problem Action
Control box does not start. Make sure that the master disconnect switch and machine power switch are on.
Check that the ignition switched power cable section of the system harness.
Start-up is interrupted by the "Error loading avoidance zone" error message. The avoidance zone file is corrupt. Contact the site supervisor.
Start-up completes but the "Direction" dialog appears. The machine direction monitor has failed. Contact the site supervisor.
To continue, press the "Escape" key. A guidance screen appears before work begins, press "Direction" to "Unknown" and set the machine direction.
Start-up completes but the error message "Some of the required devices are not responding" appears. A device specified during system configuration is missing or not connected. Refer to Service Information Section - Running system diagnostic.
Start-up completes but the error message "Check Machine Measurements" appears. The system has detected a discrepancy between a configured machine measurement, and an observed one, possibly because an incorrect machine configuration file has been loaded. Contact the site supervisor.
Start-up completes but the wrong machine icon appears on the guidance scree. Start-up completes but the wrong machine icon appears on the guidance screen.
Observe the lightbars during start-up and make sure that the lightbars work correctly.To perform the light bar start-up check:
To turn on the system power, press the "Power" key on the control box.
Immediately observe the pattern of the lightbar LEDs.The LEDs flash in the sequence described in Table 1.
Table 1
LEDs on the Lightbar Flash
Left Bottom to top
Center (horizontal) Left to right
Right Top to bottom
All Twice, simultaneously Table 2 describes the problems that may occur when powering up the internal lightbars.
Table 2
Problem Action
Lightbars do not illuminate Refer to the Section "Control Box Power Up" to check that the control box has started successfully.
or
Refer to the Section System Preparation - Lightbar Brightness to check that the lightbar brightness is not set too low. Table 3 describes the problems that may occur when powering up the external lightbars.
Table 3
Problem Action
Lightbars do not illuminate Refer to the section "Control Box Power Up" to check that the control box has started successfully.
or
Refer to the Section System Preparation - Lightbar Brightness to check that the lightbar brightness is not set too low.
or
Check the system harness between the control box and the lightbars.
Lightbars flash in the wrong sequence The lightbars have probably been installed incorrectly. Consult the site supervisor. Control Box Power Up
Observe the control box after the system has powered up.A guidance screen should be visible, and softkeys, and optional text items (if configured).If the machine has one or more 3D sensors installed and configured, the following items appear:
A plan view guidance screen
The correct machine icon for the machine type
A site plan, if the system has a site plan file
A design or map, if one was loaded when the system was last powered down.The problems in Table 4 may occur when the control box and the system are powered up.
Table 4
Problem Action
Control box does not start. Make sure that the master disconnect switch and machine power switch are on.
Check that the ignition switched power cable section of the system harness.
Start-up is interrupted by the "Error loading avoidance zone" error message. The avoidance zone file is corrupt. Contact the site supervisor.
Start-up completes but the "Direction" dialog appears. The machine direction monitor has failed. Contact the site supervisor.
To continue, press the "Escape" key. A guidance screen appears before work begins, press "Direction" to "Unknown" and set the machine direction.
Start-up completes but the error message "Some of the required devices are not responding" appears. A device specified during system configuration is missing or not connected. Refer to Service Information Section - Running system diagnostic.
Start-up completes but the error message "Check Machine Measurements" appears. The system has detected a discrepancy between a configured machine measurement, and an observed one, possibly because an incorrect machine configuration file has been loaded. Contact the site supervisor.
Start-up completes but the wrong machine icon appears on the guidance scree. Start-up completes but the wrong machine icon appears on the guidance screen.
Caterpillar parts catalog:
Parts panel Caterpillar catalog:
6G2340
PANEL AS
120G, 12G, 130G, 140G, 14G, 16G
120G, 12G, 130G, 140G, 14G, 16G
1020719
PANEL AS
120G, 12G, 140G
120G, 12G, 140G
5T7176
PANEL
120G, 12G, 130G, 140G, 14G, 16G
120G, 12G, 130G, 140G, 14G, 16G
6G3499
PANEL
120G, 12G, 130G, 140G, 14G, 16G
120G, 12G, 130G, 140G, 14G, 16G
6G2729
PANEL
120G, 12G, 130G, 140G, 14G, 16G
120G, 12G, 130G, 140G, 14G, 16G
6G2762
PANEL
120G, 12G, 130G, 140G, 14G, 16G
120G, 12G, 130G, 140G, 14G, 16G
6G2746
PANEL
120G, 12G, 130G, 140G, 14G, 16G
120G, 12G, 130G, 140G, 14G, 16G
8W3218
PANEL-INSTRUMENT
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
8D6693
PANEL
120G, 12G, 130G, 140G, 16G
120G, 12G, 130G, 140G, 16G
6G2759
PANEL
120G, 12G, 130G, 140G, 14G, 16G
120G, 12G, 130G, 140G, 14G, 16G
6G4964
PANEL
120G, 14G, 16G
120G, 14G, 16G
5R6856
PANEL
130G
130G
6G4964
PANEL
120G, 14G, 16G
120G, 14G, 16G
2Y2113
PANEL
120B, 140B
120B, 140B
6G2759
PANEL
120G, 12G, 130G, 140G, 14G, 16G
120G, 12G, 130G, 140G, 14G, 16G
8D6693
PANEL
120G, 12G, 130G, 140G, 16G
120G, 12G, 130G, 140G, 16G
8D6151
PANEL
14E
14E
9D3954
PANEL ASSEM. (Center)
120, 12F, 140, 14E
120, 12F, 140, 14E
5I3667
PANEL
350, 375, 375 L
350, 375, 375 L
2358872
PANEL AS-CONTROL
325D L, 330D L, 345C, 345C L, 365C, 385C, 385C FS, 385C L
325D L, 330D L, 345C, 345C L, 365C, 385C, 385C FS, 385C L
2243579
PANEL AS
325C
325C
1288909
PANEL AS-CONTROL
345B, 345B II, 345B II MH, 345B L, W345B II
345B, 345B II, 345B II MH, 345B L, W345B II
5R6856
PANEL
130G
130G
2D3725
PANEL ASSEM.
12E, 140
12E, 140