5089885 PENDULUM AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA5089885
508-9885
5089885
CA5089885
508-9885
5089885
Weight: 7 pounds 3 kg.
Information:
Illustration 1 g01527399
Schematic of the solenoid valve (No. 2) (forward)This circuit applies to transmissions that are "Auto" shift. This diagnostic code is associated with the solenoid valve (No. 2) (forward). The FMI 06 means that the ECM has determined that there is a short to ground in the solenoid circuit. The possible causes of this diagnostic code are listed below:
The energize circuit of the solenoid is shorted to ground.
The solenoid has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1402 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The transmission will be placed in the Neutral gear until the diagnostic has been corrected.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:The CID 1402 FMI 06 diagnostic code changes to a CID 1402 FMI 05 diagnostic code when the solenoid is disconnected.Results:
YES - The CID 1402 FMI 06 diagnostic code changes to a CID 1402 FMI 05 diagnostic code when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid.STOP
NO - The CID 1402 FMI 06 diagnostic code remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J2-2 (wire 900-PU) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-2 (wire 900-PU) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 1402 FMI 06 diagnostic code. Expected Result:The CID 1402 FMI 06 diagnostic code is active. Results:
YES - The CID 1402 FMI 06 diagnostic code is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit
Parts pendulum Caterpillar catalog:
1C4138
PENDULUM BASE
Caterpillar
Caterpillar
G41261
PENDULUM ASSY.
PR-275, PR-450
PR-275, PR-450
82510
PENDULUM SUPPORT BRACKET
PR-275, PR-450
PR-275, PR-450
82509
PENDULUM ARM
PR-275, PR-450
PR-275, PR-450
7R0225
PENDULUM AS
PR-1000, PR-450C, PR-750B
PR-1000, PR-450C, PR-750B
1751517
PENDULUM-INDICATOR
906H, 908H, 966H, BA30, BP22
906H, 908H, 966H, BA30, BP22
9N8895
PENDULUM ARM
Caterpillar
Caterpillar
9N8571
PENDULUM VIB A
Caterpillar
Caterpillar
9D0165
PENDULUM G
Caterpillar
Caterpillar
9D0160
PENDULUM G
Caterpillar
Caterpillar
9D0155
PENDULUM G
Caterpillar
Caterpillar
8C1608
PENDULUM
Caterpillar
Caterpillar