0S0130 PIN Caterpillar parts
16, 227, 231D, 235, 235D, 245, 24H, 24M, 561D, 621, 621B, 621E, 621F, 621G, 621H, 621K, 623, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 630B, 631B, 631C...
Rating:
Alternative (cross code) number:
CA0S0130
0S-0130
0S0130
CA0S0130
0S-0130
0S0130
Weight: 0.01 pounds 0 kg.
Information:
OVERALL LENGTH
14.25
mm
OUTSIDE PIN DIAMETER
6.35
mm
END TYPE A
CHAMFER
END TYPE B
CHAMFER
FLAT/VENTED
N
INSIDE DIAMETER
0
ARTICULATED TRUCK, WHEEL TRACTOR-SCRAPER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$11.76
18 Dec 2021
US: Florida-Parts-Z
0S0130 - PIN (Part of 2S4365 Assem.) 7S8188 for Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
$5.95
17 Jun 2022
Amazon.com
CTP 0S0130 Dowel Pin for Heavy Equipment
CTP Dowel Pin Only || Sold in each || Easy in-and-out fit
CTP Dowel Pin Only || Sold in each || Easy in-and-out fit
Compatible equipment models: 0S0130:
INDUSTRIAL ENGINE
D343
LANDFILL COMPACTOR
826B
LOGGER
227
PIPELAYER
561D
SOIL COMPACTOR
825B
TOWED SCRAPER
TS180
TRACK-TYPE TRACTOR
D3C
D3C II
D3C III
D4C III
D4D
D4E
D4E SR
D5
D5B
D5C III
D5E
D6C
D6D
D6E
D6E SR
D6F SR
D6G
D6G SR
D6G2 LGP
D6G2 XL
D9G
TRACTOR
768B
TRUCK
769
WAGON
772
WHEEL SCRAPER
621B
621E
621G
623E
623F
623G
627
627B
627E
627G
630B
631B
631D
633
633D
637
637B
637D
639D
641B
651
651B
657
657B
666
Information:
Instantaneous trip shutdown is fault 801.Note: Electromagnetic noise spikes can create an erroneous instantaneous trip. Such spikes are often the result of breaker closure. If the digital voltage regulator or any wiring to the digital voltage regulator is in close proximity to a circuit breaker (particularly a medium voltage breaker), this condition may occur. Uninterrupted power systems (UPS), motor drives, and other equipment that generates electromagnetic interference (EMI) spikes or switches large currents must also be avoided. Install the digital voltage regulator in the generator terminal box or in another location away from the offending equipment.
Check the wiring.
Stop the generator set.
Check the wiring.Expected Result: The wiring is correct.Results:
OK: Go to Step 2.
NOT OK: Shorted F1 and F2 wires will cause the instantaneous trip shutdown fault. Megger the exciter stator. See the proper wiring diagram for details. Refer to Testing And Adjusting, "Wiring Diagrams". STOP.
Check the accessory.
Disconnect all accessory wiring from terminals 3, 5, 6, 7, 40, 41, 42, 43, 44, 45, and 50. Remove the serial data link, if installed.
Start the generator set. Operate the generator set with the same conditions that caused the problem previously.Expected Result: The generator set operates properly.Results:
OK: The generator set operates properly. There is a problem with an accessory which has been disconnected. Reconnect one accessory. Operate the generator set again. Continue this process of reconnecting one accessory at a time until the faulty accessory is found. STOP.
NOT OK: The generator set does not operate properly. Go to Step 3.
Check the nearby equipment.
Identify nearby equipment that could generate EMI spikes.
Move the digital voltage regulator and the wiring to a temporary location away from the offending equipment and operate the generator again.Expected Result: The problem has been resolved.Results:
OK: The problem has been resolved. Find a new permanent home for the digital voltage regulator away from the offending equipment. Shielded wiring should always be used for rheostat inputs when the regulator and/or rheostat are located off the generator. Connect the shield drain wire to regulator terminal 45. Insulate the wiring shield from touching all other objects, including Earth ground.
NOT OK: The digital voltage regulator is being subjected to other sources of EMI. On methods to reduce EMI, refer to Systems Operation, "Customer Options", section Remote Installation Notes.
Check the wiring.
Stop the generator set.
Check the wiring.Expected Result: The wiring is correct.Results:
OK: Go to Step 2.
NOT OK: Shorted F1 and F2 wires will cause the instantaneous trip shutdown fault. Megger the exciter stator. See the proper wiring diagram for details. Refer to Testing And Adjusting, "Wiring Diagrams". STOP.
Check the accessory.
Disconnect all accessory wiring from terminals 3, 5, 6, 7, 40, 41, 42, 43, 44, 45, and 50. Remove the serial data link, if installed.
Start the generator set. Operate the generator set with the same conditions that caused the problem previously.Expected Result: The generator set operates properly.Results:
OK: The generator set operates properly. There is a problem with an accessory which has been disconnected. Reconnect one accessory. Operate the generator set again. Continue this process of reconnecting one accessory at a time until the faulty accessory is found. STOP.
NOT OK: The generator set does not operate properly. Go to Step 3.
Check the nearby equipment.
Identify nearby equipment that could generate EMI spikes.
Move the digital voltage regulator and the wiring to a temporary location away from the offending equipment and operate the generator again.Expected Result: The problem has been resolved.Results:
OK: The problem has been resolved. Find a new permanent home for the digital voltage regulator away from the offending equipment. Shielded wiring should always be used for rheostat inputs when the regulator and/or rheostat are located off the generator. Connect the shield drain wire to regulator terminal 45. Insulate the wiring shield from touching all other objects, including Earth ground.
NOT OK: The digital voltage regulator is being subjected to other sources of EMI. On methods to reduce EMI, refer to Systems Operation, "Customer Options", section Remote Installation Notes.
Cat SIS web machinery list:
Parts pin Caterpillar catalog:
1054079
PIN-HITCH
D25D, D350E, D350E II, D400E, D400E II, D40D
D25D, D350E, D350E II, D400E, D400E II, D40D
2U9202
PIN AS-TIP CYLINDER
725, 725C, 730, 730C, 735, 735B, 740, 740B, AD30, D25D, D300D, D300E, D350E, D350E II, D400E, D400E II, D40D
725, 725C, 730, 730C, 735, 735B, 740, 740B, AD30, D25D, D300D, D300E, D350E, D350E II, D400E, D400E II, D40D
7U2315
PIN
D25C, D25D, D30C, D350C, D350E, D350E II, D35C, D35HP, D400, D400E, D400E II, D40D
D25C, D25D, D30C, D350C, D350E, D350E II, D35C, D35HP, D400, D400E, D400E II, D40D
1421227
PIN AS
725, 725C, 730, 730C, 735, 735B, 740, 740B, D250E II, D300E II, D350E II, D400E II
725, 725C, 730, 730C, 735, 735B, 740, 740B, D250E II, D300E II, D350E II, D400E II
1929068
PIN
725, 730, 730C, 735, 735B, 740, 740B, D250E II, D300E II, D350E II, D400E II
725, 730, 730C, 735, 735B, 740, 740B, D250E II, D300E II, D350E II, D400E II
1506553
PIN
725, 725C, 730, 730C, 735, 735B, 740, 740B, AD30, D250E II, D300E II, D350E II, D400E II
725, 725C, 730, 730C, 735, 735B, 740, 740B, AD30, D250E II, D300E II, D350E II, D400E II
1550195
PIN
725C, 730C, 735, 735B, 740, 740B, D350E II, D400E II
725C, 730C, 735, 735B, 740, 740B, D350E II, D400E II
1745578
PIN-TAPERED
725, 725C, 730, 730C, 735, 735B, 740, 740B
725, 725C, 730, 730C, 735, 735B, 740, 740B
3003930
PIN-HITCH
735, 740
735, 740
2120136
PIN
735, 735B, 740, 740B
735, 735B, 740, 740B
1H4478
PIN
120, 120B, 120G, 12E, 12F, 140, 140B, 14E, 14G, 14H, 14H NA, 14M, 16, 16G, 16H, 16H NA, 16M, AD30, AD45B, AD55, AD55B, AD60, R1300G, R1300G II, R1600G, R1600H, R1700G, R2900G, R3000H
120, 120B, 120G, 12E, 12F, 140, 140B, 14E, 14G, 14H, 14H NA, 14M, 16, 16G, 16H, 16H NA, 16M, AD30, AD45B, AD55, AD55B, AD60, R1300G, R1300G II, R1600G, R1600H, R1700G, R2900G, R3000H
9M1609
PIN
768B, 769, 769C
768B, 769, 769C
4L9202
PIN
D398, D399
D398, D399
2L4911
PIN (SPRING)
D320A, D342, D342C, D343, D353C, D379, D398, D399
D320A, D342, D342C, D343, D353C, D379, D398, D399
1H6067
PIN
D342, D343, D353C, D6D, G353D
D342, D343, D353C, D6D, G353D
4B4712
PIN
D342, D343, D353C, G353D
D342, D343, D353C, G353D
4B4724
PIN
D342, D343, D353C, G353D
D342, D343, D353C, G353D
5B4699
PIN
G342C
G342C
7K9499
PIN
955K, 955L
955K, 955L
7K9503
PIN
955K, 955L
955K, 955L
7K9506
PIN
955K, 955L
955K, 955L
7K9501
PIN
955K, 955L
955K, 955L
8K6315
PIN
955K, 955L
955K, 955L
5L4684
PIN
G342C
G342C