Illustration 1 g01156447
Schematic of the Travel Lock MagnetThis diagnostic code is associated with the Travel Lock Magnet. The FMI 06 means that the ECM has determined that the current of the magnet is above normal. The possible causes of this diagnostic code are listed:
The energize circuit of the magnet is shorted to ground.
The magnet has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1622 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.Test Step 1. CHECK THE MAGNET.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the magnet with the active diagnostic code from the machine harness. Expected Result:CID 1622 FMI 06 changes to CID 1622 FMI 05 when the magnet is disconnected.Results:
YES - CID 1622 FMI 06 changes to CID 1622 FMI 05 when the magnet is disconnected. The circuit is correct.Repair: The magnet has failed. Repeat this test "CHECK THE MAGNET" in order to verify the failure of the magnet. Replace the magnet. Stop.
NO - CID 1622 FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The magnet remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J2-60 (wire M956-GN) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-60 (wire M956-GN) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. Stop.Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 1622 FMI 06. Expected Result:The CID 1622 FMI 06 is active. Results:
YES - The CID 1622 FMI 06 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
NO - The CID 1622 FMI 06 is not active. The diagnostic code does not exist at this time. Repair:
Parts pin Caterpillar catalog:
1K1487
PIN
Caterpillar
Caterpillar
1K1444
PIN
Caterpillar
Caterpillar
1K1318
PIN
Caterpillar
Caterpillar
1K1317
PIN
Caterpillar
Caterpillar
1K1309
PIN A.-CLUTCH
Caterpillar
Caterpillar
1K1233
PIN
Caterpillar
Caterpillar
1K1754
PIN
Caterpillar
Caterpillar
1K1704
PIN
Caterpillar
Caterpillar
1K1700
PIN
Caterpillar
Caterpillar
1K1689
PIN
Caterpillar
Caterpillar
1K1571
PIN G.-HINGE
Caterpillar
Caterpillar
1K1570
PIN
Caterpillar
Caterpillar