2097455 PIN Caterpillar parts
414E, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424D, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 442D, 442E, 450E, 450F, TH210, TH215, TH220B, TH330B, TH340B, TH350B, TH355B
Rating:
Alternative (cross code) number:
CA2097455
209-7455
2097455
CA2097455
209-7455
2097455
Weight: 0.79 pounds 0 kg.
Information:
EFFECTIVE LENGTH
122
mm
HEAD OD
0
mm
OVERALL LENGTH
130
mm
PIN OD
22
mm
TRANSV HOLES
Y
DETENT BALL
N
END TYPE A
CHAMFER
END TYPE B
CHAMFER
GROOVE
N
HAND RING
N
HEAD THICKNESS
0
KEEPER SLOT
N
LUBE OUTLETS
N
BACKHOE LOADER, TELEHANDLER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 2097455:
Information:
Introduction
The information in this section is a supplement to the Checks and Tests of the previous sections. This material is much more descriptive and detailed for the user who is less familiar with these systems. The Troubleshooting Section makes constant references to this section when more detailed information is necessary to complete a test.Service Procedure Index For 2301 Electric Governor
A. Nonparallel Control (Standby Unit)B. Parallel Control (Load Sharing)C. Low Idle Speed AdjustmentD. Actuator Check ProcedureE. Linkage CalibrationF. Power RequirementsG. Speed SettingH. Minimum Fuel SwitchJ. Gain and StabilityK. Magnetic PickupL. DroopM. Load GainN. De-DroopP. PhasingQ. Acceleration RateR. Droop or Isochronous Mode SwitchS. 2301 Bench Performance CheckT. 2301 Operating ConditionsU. Incompatibility of Multiple Load Sharing Control UnitsV. 2301 Overvoltage ProtectionW. Voltage Drop to 2301 Control During Cold Start ConditionsProcedure A
2301 Nonparallel Control (Standby Unit)
2301 NONPARALLEL CONTROL BOX (8N408 SHOWN)
WIRING DIAGRAM FOR 8N408 CONTROLNOTE A: Lube oil Idle Switch maintains Low Idle speed until oil pressure closes switch. Another switch can be added in series for low speed control at the switchgear.NOTE B: A 500 ohm (max.) remote speed setting potentiometer gives approximately 1% speed change per 20 ohms.NOTE C: 20K DROOP potentiometer. Must be left open if not used.NOTE D: Acceleration rate capacitor causes additional acceleration time of 2 seconds per 50 mfd. Must be left open if not used.NOTE E: Shielded wires should be twisted pairs.NOTE F: Ground battery negative to switchgear frame and neutral bus.NOTE G: Install shielded cable directly from component to control box. Do not go through terminal points. Connect shields only at control box grounding stud.NOTE H: Installed on engine by CTCo.NOTE J: For speed range of magnetic pickup, see Magnetic Pickup Frequencies For Electric Governors in Service Procedure K.Procedure B
2301 Parallel Control (Load Sharing)
2301 PARALLEL CONTROL BOX (8N409 SHOWN)
FIGURE 1 WIRING DIAGRAM FOR 2301 PARALLEL CONTROL (8N409)NOTE A: When power is removed for service, open both positive (+) and negative (-) supply leads (terminal T25 when used and terminal T11 if not opened by auxiliary contacts). Prevent leads from making contact with ground or from shorting together if not connected through a switch.NOTE B: Remove jumper between terminals T20 and T21 when remote speed potentiometer is used. A high quality 100 ohm, 10 turn potentiometer is recommended. A resistance of 100 ohms "rheostat connected" will give approximately 4% speed adjustment.NOTE C: For actuators used in tandem (series) operation, connect as shown at bottom of Fig. 1. Put jumper across control terminals T17 and T28 when two actuators in series are used.NOTE D: This control has inside burden resistors. These burden resistors must be connected across power source current transformers while unit is running to prevent the development of high voltage in the leads to these terminals.NOTE E: When the circuit breaker to main bus closes, the contacts of the auxiliary circuit breaker must close pilot relay contacts at the same time. Since only one pilot relay contact is used with the time control, remove the pilot relay contact in line connected to
The information in this section is a supplement to the Checks and Tests of the previous sections. This material is much more descriptive and detailed for the user who is less familiar with these systems. The Troubleshooting Section makes constant references to this section when more detailed information is necessary to complete a test.Service Procedure Index For 2301 Electric Governor
A. Nonparallel Control (Standby Unit)B. Parallel Control (Load Sharing)C. Low Idle Speed AdjustmentD. Actuator Check ProcedureE. Linkage CalibrationF. Power RequirementsG. Speed SettingH. Minimum Fuel SwitchJ. Gain and StabilityK. Magnetic PickupL. DroopM. Load GainN. De-DroopP. PhasingQ. Acceleration RateR. Droop or Isochronous Mode SwitchS. 2301 Bench Performance CheckT. 2301 Operating ConditionsU. Incompatibility of Multiple Load Sharing Control UnitsV. 2301 Overvoltage ProtectionW. Voltage Drop to 2301 Control During Cold Start ConditionsProcedure A
2301 Nonparallel Control (Standby Unit)
2301 NONPARALLEL CONTROL BOX (8N408 SHOWN)
WIRING DIAGRAM FOR 8N408 CONTROLNOTE A: Lube oil Idle Switch maintains Low Idle speed until oil pressure closes switch. Another switch can be added in series for low speed control at the switchgear.NOTE B: A 500 ohm (max.) remote speed setting potentiometer gives approximately 1% speed change per 20 ohms.NOTE C: 20K DROOP potentiometer. Must be left open if not used.NOTE D: Acceleration rate capacitor causes additional acceleration time of 2 seconds per 50 mfd. Must be left open if not used.NOTE E: Shielded wires should be twisted pairs.NOTE F: Ground battery negative to switchgear frame and neutral bus.NOTE G: Install shielded cable directly from component to control box. Do not go through terminal points. Connect shields only at control box grounding stud.NOTE H: Installed on engine by CTCo.NOTE J: For speed range of magnetic pickup, see Magnetic Pickup Frequencies For Electric Governors in Service Procedure K.Procedure B
2301 Parallel Control (Load Sharing)
2301 PARALLEL CONTROL BOX (8N409 SHOWN)
FIGURE 1 WIRING DIAGRAM FOR 2301 PARALLEL CONTROL (8N409)NOTE A: When power is removed for service, open both positive (+) and negative (-) supply leads (terminal T25 when used and terminal T11 if not opened by auxiliary contacts). Prevent leads from making contact with ground or from shorting together if not connected through a switch.NOTE B: Remove jumper between terminals T20 and T21 when remote speed potentiometer is used. A high quality 100 ohm, 10 turn potentiometer is recommended. A resistance of 100 ohms "rheostat connected" will give approximately 4% speed adjustment.NOTE C: For actuators used in tandem (series) operation, connect as shown at bottom of Fig. 1. Put jumper across control terminals T17 and T28 when two actuators in series are used.NOTE D: This control has inside burden resistors. These burden resistors must be connected across power source current transformers while unit is running to prevent the development of high voltage in the leads to these terminals.NOTE E: When the circuit breaker to main bus closes, the contacts of the auxiliary circuit breaker must close pilot relay contacts at the same time. Since only one pilot relay contact is used with the time control, remove the pilot relay contact in line connected to
Cat SIS web machinery list:
Parts pin Caterpillar catalog:
3166951
PIN AS
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 442E, 444E, 444F
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 442E, 444E, 444F
3166952
PIN AS
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 442E, 444E, 444F
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 442E, 444E, 444F
3260089
PIN AS
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 444F
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 444F
3863778
PIN AS
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 442E, 444E, 444F
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 442E, 444E, 444F
3209164
PIN
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 442E, 444E, 444F
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 442E, 444E, 444F
3209241
PIN
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 442E, 444E, 444F
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 442E, 444E, 444F
3285234
PIN
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 442E, 444E, 444F
422E, 422F, 428E, 428F, 432E, 432F, 434E, 434F, 442E, 444E, 444F
3224583
PIN
428E, 432E, 442E
428E, 432E, 442E
3224584
PIN
428E, 432E, 442E
428E, 432E, 442E
3224585
PIN
428E, 432E, 442E
428E, 432E, 442E
3224586
PIN
428E, 432E, 442E
428E, 432E, 442E
3224587
PIN
428E, 432E, 442E
428E, 432E, 442E
2167473
PIN AS
414E, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424D, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 442D, 442E, 444E, 444F, 450E, 450F, TH220B, TH330B, TH340B, TH350B, TH355B...
414E, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424D, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 442D, 442E, 444E, 444F, 450E, 450F, TH220B, TH330B, TH340B, TH350B, TH355B...
2088914
PIN AS
TH220B, TH330B, TH340B, TH350B, TH355B
TH220B, TH330B, TH340B, TH350B, TH355B
2761151
PIN-CONNECTOR
2384C, 2484C, 3054C, 3054E, 308E2 CR, 312E, 312E L, 314E CR, 314E LCR, 316E L, 318E L, 3508, 3508B, 3508C, 3512B, 3512C, 3516C, 414E, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424D, 428D, 428E, ...
2384C, 2484C, 3054C, 3054E, 308E2 CR, 312E, 312E L, 314E CR, 314E LCR, 316E L, 318E L, 3508, 3508B, 3508C, 3512B, 3512C, 3516C, 414E, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424D, 428D, 428E, ...
2126408
PIN-CLEVIS
TL5 30
TL5 30
2116682
PIN
TL5 30
TL5 30
2093710
PIN
TL5 30
TL5 30
2224652
PIN AS
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
2453997
PIN
TH350B, TH355B, TH460B, TH560B
TH350B, TH355B, TH460B, TH560B
2385262
PIN
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
1381645
PIN-SPRING
2470C, 2570C, 2670C, 2864C, 515, 525, 525B, 525C, 525D, 533, 535B, 535C, 535D, 543, 545, 545C, 545D, 553C, 555D, 561N, 563C, 573C, 586C, 621E, 621F, 621G, 623E, 623G, 627E, 627G, 631E, 631G, 633E II, ...
2470C, 2570C, 2670C, 2864C, 515, 525, 525B, 525C, 525D, 533, 535B, 535C, 535D, 543, 545, 545C, 545D, 553C, 555D, 561N, 563C, 573C, 586C, 621E, 621F, 621G, 623E, 623G, 627E, 627G, 631E, 631G, 633E II, ...
2097467
PIN
901C, 902C, 903C, 906H, 906H2, 907H, 907H2, 908H, 908H2, TH220B, TH330B, TH340B, TH350B, TH355B
901C, 902C, 903C, 906H, 906H2, 907H, 907H2, 908H, 908H2, TH220B, TH330B, TH340B, TH350B, TH355B
2097471
PIN
TH220B, TH330B, TH340B, TH350B, TH355B
TH220B, TH330B, TH340B, TH350B, TH355B