2458356 PIN AS.-TRACK Caterpillar parts
Rating:
Alternative (cross code) number:
CA2458356
245-8356
2458356
CA2458356
245-8356
2458356
Information:
Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps    Values    Results    
1. Check for Diagnostic Codes that are Active
A. Establish communication between Cat® ET and the Electronic Control Module (ECM). Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Download the "Warranty Report" from the engine ECM before performing any troubleshooting or clearing diagnostic trouble codes.
C. Check and record any event codes that are active or logged.
   
Diagnostic Code
   
Result: A E1239 (1), E1239 (2), E1239 (3), 3750-31, 3750-17 or 3750-18 diagnostic code is present, proceed to Test Step 2.
Result: A E993 (3) or 3703-31 diagnostic code is present, proceed to Test Step 3.
Result: A E1040 (2) or 3530-31 diagnostic code is present, proceed to Test Step 4.
Result: An E1300 (1), E1300 (2), 3716-15 or 3716-31 diagnostic code is present, proceed to Test Step 5.
Result: A E1301 (1) or 3712-15 diagnostic code is present, proceed to Test Step 6.
Result: A E1302 (1) or 3750-15 diagnostic code is present, proceed to Test Step 7.
Result: A E1305 (1) or 3483-11 diagnostic code is present, proceed to Test Step 8.
   
2. A E1239 (1), E1239 (2), E1239 (3), 3750-31, 3750-17 or 3750-18 Diagnostic Code is Present.
A. The operator did not allow a regeneration to occur or an automatic regeneration did not occur within the required time limit. The operator must respond when the DPF lamp is illuminated.
B. Perform a "Forced Regeneration" by pressing the "Regeneration Force Switch" button.
   
Forced Regeneration
   
Result: The "Forced Regeneration" was successful.
Return the unit to service.
Result: The "Forced Regeneration" was not successful.
Repair: Troubleshoot the active diagnostic codes.
   
3. A E993 (3) or 3703-31 Diagnostic Code is Present.
A. The operator has disabled the regeneration system and a regeneration is necessary.
   
Disabled Regeneration
   
Result: Perform a regeneration. Refer to the Operation and Maintenance Manual, "Diesel Particulate Filter Regeneration" for the proper operation of the regeneration system.
Return the unit to service.
   
4. A E1040 (2) or 3530-31 Diagnostic Code is Present.
A. The regeneration system is disabled by Cat ET.
   
Regeneration Disabled by Cat ET.
   
Result: Establish communication between Cat ET and the engine ECM. Set the value of the "Aftertreatment Regeneration Device" from "Disabled" to "Enabled".
Return the unit to service.
   
5. Aftertreatment Regeneration Cannot Start Due To Low Engine Temperature
A. The engine temperature is too low for an aftertreatment regeneration.
   
Low Engine Temperature
   
Result: Raise the coolant temperature above
40° C (104° F ) and the Diesel Particulate Filter inlet temperature above
50° C (122° F). If the ambient temperature is
-15° C (5° F) or below, the coolant temperature must be above
60° C (140° F) for an active regeneration to begin.
Return the unit to service.
   
6. Aftertreatment Regeneration Cannot Start Due to System Fault
A. Establish communication between the Caterpillar Electronic Technician (ET) and the engine Electronic Control Module (ECM).
B. Check for active faults related to the ARD combustion air system, ARD fuel system,
Table 2
Troubleshooting Test Steps    Values    Results    
1. Check for Diagnostic Codes that are Active
A. Establish communication between Cat® ET and the Electronic Control Module (ECM). Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Download the "Warranty Report" from the engine ECM before performing any troubleshooting or clearing diagnostic trouble codes.
C. Check and record any event codes that are active or logged.
   
Diagnostic Code
   
Result: A E1239 (1), E1239 (2), E1239 (3), 3750-31, 3750-17 or 3750-18 diagnostic code is present, proceed to Test Step 2.
Result: A E993 (3) or 3703-31 diagnostic code is present, proceed to Test Step 3.
Result: A E1040 (2) or 3530-31 diagnostic code is present, proceed to Test Step 4.
Result: An E1300 (1), E1300 (2), 3716-15 or 3716-31 diagnostic code is present, proceed to Test Step 5.
Result: A E1301 (1) or 3712-15 diagnostic code is present, proceed to Test Step 6.
Result: A E1302 (1) or 3750-15 diagnostic code is present, proceed to Test Step 7.
Result: A E1305 (1) or 3483-11 diagnostic code is present, proceed to Test Step 8.
   
2. A E1239 (1), E1239 (2), E1239 (3), 3750-31, 3750-17 or 3750-18 Diagnostic Code is Present.
A. The operator did not allow a regeneration to occur or an automatic regeneration did not occur within the required time limit. The operator must respond when the DPF lamp is illuminated.
B. Perform a "Forced Regeneration" by pressing the "Regeneration Force Switch" button.
   
Forced Regeneration
   
Result: The "Forced Regeneration" was successful.
Return the unit to service.
Result: The "Forced Regeneration" was not successful.
Repair: Troubleshoot the active diagnostic codes.
   
3. A E993 (3) or 3703-31 Diagnostic Code is Present.
A. The operator has disabled the regeneration system and a regeneration is necessary.
   
Disabled Regeneration
   
Result: Perform a regeneration. Refer to the Operation and Maintenance Manual, "Diesel Particulate Filter Regeneration" for the proper operation of the regeneration system.
Return the unit to service.
   
4. A E1040 (2) or 3530-31 Diagnostic Code is Present.
A. The regeneration system is disabled by Cat ET.
   
Regeneration Disabled by Cat ET.
   
Result: Establish communication between Cat ET and the engine ECM. Set the value of the "Aftertreatment Regeneration Device" from "Disabled" to "Enabled".
Return the unit to service.
   
5. Aftertreatment Regeneration Cannot Start Due To Low Engine Temperature
A. The engine temperature is too low for an aftertreatment regeneration.
   
Low Engine Temperature
   
Result: Raise the coolant temperature above
40° C (104° F ) and the Diesel Particulate Filter inlet temperature above
50° C (122° F). If the ambient temperature is
-15° C (5° F) or below, the coolant temperature must be above
60° C (140° F) for an active regeneration to begin.
Return the unit to service.
   
6. Aftertreatment Regeneration Cannot Start Due to System Fault
A. Establish communication between the Caterpillar Electronic Technician (ET) and the engine Electronic Control Module (ECM).
B. Check for active faults related to the ARD combustion air system, ARD fuel system,
Parts pin Caterpillar catalog:
2456281
PIN
Caterpillar
Caterpillar
2454081
PIN-
Caterpillar
Caterpillar
2454079
PIN-
Caterpillar
Caterpillar
2454077
PIN-
Caterpillar
Caterpillar
2448543
PIN AS
Caterpillar
Caterpillar
2448533
PIN AS
Caterpillar
Caterpillar
2466047
PIN AS
Caterpillar
Caterpillar
2464270
PIN AS.-POS
Caterpillar
Caterpillar
2464269
PIN AS.-POS
Caterpillar
Caterpillar
2464081
PIN
Caterpillar
Caterpillar
2460826
PIN
Caterpillar
Caterpillar
2458357
PIN AS.-TRACK
Caterpillar
Caterpillar