2S1602 PIN Caterpillar parts
641B, 772, D346, D348
Rating:
Alternative (cross code) number:
CA2S1602
2S-1602
2S1602
CA2S1602
2S-1602
2S1602
Weight: 0.36 pounds 0 kg.
INDUSTRIAL ENGINE, WHEEL TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 2S1602:
Information:
Intended Use
This power module is intended for use in generating electrical power. The power module is a complete self-contained unit that can be towed to any location for the generation of electrical power. The power module can be utilized for prime power generation or standby power generation.Engine
Cat 3512C HD Engines provide the following features:
Four-cycle
Direct fuel injection
Mechanical Electronic Unit Injector (MEUI)
TurbochargedLube Oil Makeup System
The lube oil makeup system is located on the personnel access door on the right side of the power module. The lube oil makeup system consists of the following:
two sight glasses (1/3 full, and 2/3 full)
113.6 L (30 US gal) capacity
low-level sensor outputs to controller (used to give low-level warning alarm)Electronic Engine Features
Cat 3512C HD Engines are designed with electronic controls. The integral on board computer controls the operation of the engine. Current operating conditions are monitored. The Electronic Control Module (ECM) controls the response of the engine to these conditions and to the demands of the operator. These conditions and operator demands determine the precise control of fuel injection by the ECM. The electronic engine control system provides the following features:
Engine and auxiliary monitoring
Engine speed governing
Cold start strategy
Automatic air/fuel ratio control
Torque rise shaping
Automatic altitude compensation
Injection timing control
System diagnosticsFor more information on electronic engine features, refer to the Operation and Maintenance Manual, "Features and Controls" topic (Operation Section).Generator
The SR5 brushless generator can be used with the following loads: mixed loads of motors and lights, SCR-controlled equipment, computer centers, installations of communications and petroleum drilling applications.SR5 generators are utilized in three-phase full-wave excitation and regulation. The generator is a wye configuration intended for nominal voltages of 400V or 480V, and produces electrical power in 50 Hz or 60 Hz applications.Power Module Enclosure
Basic Container
The enclosure for the power module is a shipping container. The container meets the following standards and regulations:
ISO/TC 104 Requirements for cargo containers
ANSI/ MH5.1 Basic requirements for cargo containers
ANSI/MH5.1.1 Requirements for closed van containers
UIC Code 592-1 International union of railwayLoad Cable Access Door
Illustration 1 g03642248
Load cable access door
Illustration 2 g03594125
Bus bar with connected load leads
The load cable access door is located on the side of the power module. The door has a lock handle that requires a Cat key to unlock, for access into the bus bar area.The load cable access door shall remain closed and locked during normal operation. During extended run time, a qualified service technician may be necessary in order to open this door occasionally, to take temperature scans on the bus bars, for example.A transparent shield is located in front of the bus bars to protect personnel against accidental contact with energized parts. This shield is held secure by four captive fasteners. The shield must be in place before the generator circuit breaker is allowed to close. If the shield is removed while the unit is powering the load, the generator breaker will be tripped open. There are two limit switches that detect when the shield is installed. One is used to trip the generator breaker. The other is entirely for customer use,
This power module is intended for use in generating electrical power. The power module is a complete self-contained unit that can be towed to any location for the generation of electrical power. The power module can be utilized for prime power generation or standby power generation.Engine
Cat 3512C HD Engines provide the following features:
Four-cycle
Direct fuel injection
Mechanical Electronic Unit Injector (MEUI)
TurbochargedLube Oil Makeup System
The lube oil makeup system is located on the personnel access door on the right side of the power module. The lube oil makeup system consists of the following:
two sight glasses (1/3 full, and 2/3 full)
113.6 L (30 US gal) capacity
low-level sensor outputs to controller (used to give low-level warning alarm)Electronic Engine Features
Cat 3512C HD Engines are designed with electronic controls. The integral on board computer controls the operation of the engine. Current operating conditions are monitored. The Electronic Control Module (ECM) controls the response of the engine to these conditions and to the demands of the operator. These conditions and operator demands determine the precise control of fuel injection by the ECM. The electronic engine control system provides the following features:
Engine and auxiliary monitoring
Engine speed governing
Cold start strategy
Automatic air/fuel ratio control
Torque rise shaping
Automatic altitude compensation
Injection timing control
System diagnosticsFor more information on electronic engine features, refer to the Operation and Maintenance Manual, "Features and Controls" topic (Operation Section).Generator
The SR5 brushless generator can be used with the following loads: mixed loads of motors and lights, SCR-controlled equipment, computer centers, installations of communications and petroleum drilling applications.SR5 generators are utilized in three-phase full-wave excitation and regulation. The generator is a wye configuration intended for nominal voltages of 400V or 480V, and produces electrical power in 50 Hz or 60 Hz applications.Power Module Enclosure
Basic Container
The enclosure for the power module is a shipping container. The container meets the following standards and regulations:
ISO/TC 104 Requirements for cargo containers
ANSI/ MH5.1 Basic requirements for cargo containers
ANSI/MH5.1.1 Requirements for closed van containers
UIC Code 592-1 International union of railwayLoad Cable Access Door
Illustration 1 g03642248
Load cable access door
Illustration 2 g03594125
Bus bar with connected load leads
The load cable access door is located on the side of the power module. The door has a lock handle that requires a Cat key to unlock, for access into the bus bar area.The load cable access door shall remain closed and locked during normal operation. During extended run time, a qualified service technician may be necessary in order to open this door occasionally, to take temperature scans on the bus bars, for example.A transparent shield is located in front of the bus bars to protect personnel against accidental contact with energized parts. This shield is held secure by four captive fasteners. The shield must be in place before the generator circuit breaker is allowed to close. If the shield is removed while the unit is powering the load, the generator breaker will be tripped open. There are two limit switches that detect when the shield is installed. One is used to trip the generator breaker. The other is entirely for customer use,
Cat SIS web machinery list:
Parts pin Caterpillar catalog:
4S7808
PIN ASSEM.
650B, 773, 992, D346, D348
650B, 773, 992, D346, D348
7L0537
PIN
777, D346, D348, D349
777, D346, D348, D349
5B4689
PIN
D398, D399, G379, G398
D398, D399, G379, G398
2N2191
PIN
D348
D348
2A4131
PIN
D315, D342, D353C, D379A, G379
D315, D342, D353C, D379A, G379
5B4687
PIN
D315, D326F, D343, D353C
D315, D326F, D343, D353C
2N7030
PIN ASSEM.
D343
D343
2L2076
PIN
3304, 3306, D320A, D342, D342C, D343, D353C, G3306, G342C, G343
3304, 3306, D320A, D342, D342C, D343, D353C, G3306, G342C, G343
2L3966
PIN
D342C
D342C
1C2235
PIN (.007"O''SIZE)
D326F, D337, D342, D397D
D326F, D337, D342, D397D
1C0002
PIN (STD.)
D326F, D337, D342, D397D
D326F, D337, D342, D397D
2N0147
PIN (Part of 2N4724 Assem.)
D346, D348, D349, D379B
D346, D348, D349, D379B