7K6497 PIN Caterpillar parts
920
Rating:
Alternative (cross code) number:
CA7K6497
7K-6497
7K6497
CA7K6497
7K-6497
7K6497
Weight: 2 pounds 0 kg.
WHEEL LOADER,
Related part:
7K6497
PIN-YM
2526870
CL
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$11.02
28 Apr 2021
Amazon.com
7K6497 Pin CGR Ghinassi - Made in Italy
CGR Compatible Models - 920 || Related Items - 7K9927 7K9592 7K9201 7K9348 7K9928 9K9589 7K9202 6K8316 6K6175 || Interchange - 2526870 || BUCKET CONTROL GP
CGR Compatible Models - 920 || Related Items - 7K9927 7K9592 7K9201 7K9348 7K9928 9K9589 7K9202 6K8316 6K6175 || Interchange - 2526870 || BUCKET CONTROL GP
Compatible equipment models: 7K6497:
Information:
Series Boost (Attachment)
Series Boost Module (Attachment)
(1) Series boost module. (2) Current transformer T2Series boost keeps self-excited SR4 generators on the line, for approximately 10 seconds, when there is a short in the generating or load circuits. This gives circuit breakers a chance to trip in sequence. When circuit breakers trip in sequence, there is less chance for a loss of power to all of the electrical system.The series boost module and current transformer (T2) make up the series boost.Reference: For the most current information on connecting to the primary side of the transformer, see Special Instructions, SELS0071-01.Voltage sensing and power are applied to the series boost module from the voltage sensing terminals 22 and 24 of the regulator.When the sensed voltage is within normal limits, an electrical signal is sent to the gate of a triac located in the series boost module. This triac short circuits current transformer (T2). This prevents any series boost during normal operation.If there is a short circuit that causes the voltage at the regulator sensing terminals to drop to a low value, the control signal to the gate of the triac will be turned off. Current from current transformer (T2) will be rectified and applied directly to exciter stator (L1). This field current will be enough to give at least three times full load current into a short circuit. After approximately ten seconds a timer within the series boost module will again cause a control signal to be applied to the gate of the triac. The triac will short circuit transformer (T2). Current flow to exciter stator (L1) will be zero until the short circuit is corrected.Remove Voltage Control (Attachment)
Partial View Of Regulator
(1) Potentiometer. (2) Jumper. (3) Regulator.Generator output voltage level can be controlled from a remote location. This is done by connecting potentiometer (1) between terminals (6 and 7) on voltage regulator (3). Remove jumper link (2) between terminals (4 and 7) for remote voltage level control.For acceptable voltage control, the remote mounted potentiometer must be a three turn, 10K ohm 5%, with a dielectric strength of 1000 VAC minimum (reference 7C4471).Wiring to the remote mounted potentiometer (connecting to) must be 18 gauge or smaller. The wire should be 600 volt class with a 90°C insulation. Either the jumper between terminals (4 and 7) or the remote potentiometer between terminals (6 and 7) is required for operation.
Series Boost Module (Attachment)
(1) Series boost module. (2) Current transformer T2Series boost keeps self-excited SR4 generators on the line, for approximately 10 seconds, when there is a short in the generating or load circuits. This gives circuit breakers a chance to trip in sequence. When circuit breakers trip in sequence, there is less chance for a loss of power to all of the electrical system.The series boost module and current transformer (T2) make up the series boost.Reference: For the most current information on connecting to the primary side of the transformer, see Special Instructions, SELS0071-01.Voltage sensing and power are applied to the series boost module from the voltage sensing terminals 22 and 24 of the regulator.When the sensed voltage is within normal limits, an electrical signal is sent to the gate of a triac located in the series boost module. This triac short circuits current transformer (T2). This prevents any series boost during normal operation.If there is a short circuit that causes the voltage at the regulator sensing terminals to drop to a low value, the control signal to the gate of the triac will be turned off. Current from current transformer (T2) will be rectified and applied directly to exciter stator (L1). This field current will be enough to give at least three times full load current into a short circuit. After approximately ten seconds a timer within the series boost module will again cause a control signal to be applied to the gate of the triac. The triac will short circuit transformer (T2). Current flow to exciter stator (L1) will be zero until the short circuit is corrected.Remove Voltage Control (Attachment)
Partial View Of Regulator
(1) Potentiometer. (2) Jumper. (3) Regulator.Generator output voltage level can be controlled from a remote location. This is done by connecting potentiometer (1) between terminals (6 and 7) on voltage regulator (3). Remove jumper link (2) between terminals (4 and 7) for remote voltage level control.For acceptable voltage control, the remote mounted potentiometer must be a three turn, 10K ohm 5%, with a dielectric strength of 1000 VAC minimum (reference 7C4471).Wiring to the remote mounted potentiometer (connecting to) must be 18 gauge or smaller. The wire should be 600 volt class with a 90°C insulation. Either the jumper between terminals (4 and 7) or the remote potentiometer between terminals (6 and 7) is required for operation.
Caterpillar parts catalog:
Parts pin Caterpillar catalog:
3B4604
PIN-COTTER
1150, 1160, 120G, 12E, 12F, 12G, 130G, 140, 140G, 14E, 14G, 16, 1673, 1693, 16G, 173B, 183B, 225, 245, 3116, 3126, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3508, ...
1150, 1160, 120G, 12E, 12F, 12G, 130G, 140, 140G, 14E, 14G, 16, 1673, 1693, 16G, 173B, 183B, 225, 245, 3116, 3126, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3508, ...
3B4610
PIN-COTTER
120, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12E, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 130G, 135H, 135H NA, 140, 140B, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, ...
120, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12E, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 130G, 135H, 135H NA, 140, 140B, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, ...
6B6863
PIN-SPRING
12E, 14E, 16, 24H, 24M, 30/30, 3176, 3176B, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 3606, 3608, 3612, 3616, 508, 517, 518, 518C, 527, 528, 528B, 530B, 54, 561M, 561N, 572R, ...
12E, 14E, 16, 24H, 24M, 30/30, 3176, 3176B, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 3606, 3608, 3612, 3616, 508, 517, 518, 518C, 527, 528, 528B, 530B, 54, 561M, 561N, 572R, ...
3B4611
PIN-COTTER
10 FT, 10B, 117, 118, 119, 128, 129, 140, 16, 172, 184, 235, 245, 245B, 24M, 2670C, 30, 303E CR, 305.5E, 308E, 308E CR, 3160, 35, 414E, 416C, 416E, 420D, 420E, 420F, 422E, 426C, 428C, 428E, 428F, 430E...
10 FT, 10B, 117, 118, 119, 128, 129, 140, 16, 172, 184, 235, 245, 245B, 24M, 2670C, 30, 303E CR, 305.5E, 308E, 308E CR, 3160, 35, 414E, 416C, 416E, 420D, 420E, 420F, 422E, 426C, 428C, 428E, 428F, 430E...
4V7277
PIN
518, 528, 528B, 530B, 613C, 613C II, 613G, 65, 65E, 725, 725C, 730, 730C, 75E, 769C, 773B, 85E, 916, 920, 926, 930, 936, 950, 950B, 950B/950E, 95E, D250D, D250E, D250E II, D300B, D300D, D300E, D300E I...
518, 528, 528B, 530B, 613C, 613C II, 613G, 65, 65E, 725, 725C, 730, 730C, 75E, 769C, 773B, 85E, 916, 920, 926, 930, 936, 950, 950B, 950B/950E, 95E, D250D, D250E, D250E II, D300B, D300D, D300E, D300E I...
1T0289
PIN
3192, 517, 518, 518C, 613, 613B, 613C, 613C II, 7261, 910, 920, 930, 930R, 931B, 936, 936F, 941, 950, 955H, 966C, 966R, D250D, D3B, D4D, D4E, D4H, D4H XL, D4HTSK II, D4HTSK III, G936
3192, 517, 518, 518C, 613, 613B, 613C, 613C II, 7261, 910, 920, 930, 930R, 931B, 936, 936F, 941, 950, 955H, 966C, 966R, D250D, D3B, D4D, D4E, D4H, D4H XL, D4HTSK II, D4HTSK III, G936
3H6660
PIN
120B, 12E, 140, 140B, 14E, 16, 229, 235, 235C, 245, 375 L, 528, 561C, 571G, 572G, 572R, 572R II, 578, 583H, 583K, 583R, 583T, 587R, 587T, 589, 594H, 630B, 631D, 631E, 631G, 637D, 637E, 637G, 641B, 651...
120B, 12E, 140, 140B, 14E, 16, 229, 235, 235C, 245, 375 L, 528, 561C, 571G, 572G, 572R, 572R II, 578, 583H, 583K, 583R, 583T, 587R, 587T, 589, 594H, 630B, 631D, 631E, 631G, 637D, 637E, 637G, 641B, 651...
4N8179
PIN
120B, 120G, 12G, 130G, 140B, 140G, 14G, 1673C, 215, 225, 235, 3304, 3306, 518, 627B, 637D, 920, 930, 941, 950, 951B, 955K, 955L, 966C, 977K, D4D, D4E, D5, D5B, D6C, D6D, D7F, D7G
120B, 120G, 12G, 130G, 140B, 140G, 14G, 1673C, 215, 225, 235, 3304, 3306, 518, 627B, 637D, 920, 930, 941, 950, 951B, 955K, 955L, 966C, 977K, D4D, D4E, D5, D5B, D6C, D6D, D7F, D7G
6K7285
PIN
920
920
6K8316
PIN
920
920
6K8542
PIN
920
920
6K2703
PIN (Lower)
508, 920
508, 920
3B4961
PIN
631C, 637
631C, 637
8J3431
PIN
613, 613B
613, 613B
8J4349
PIN
920
920
1B0671
PIN
920, 930, 930R
920, 930, 930R
8J1042
PIN
613
613
6J3970
PIN
613
613
9K3021
PIN ASSEM.
920, 930
920, 930
7J5505
PIN
641B, 651B, 666
641B, 651B, 666
8J5028
PIN
613
613
7J6886
PIN
613
613
7S4856
PIN
641B
641B