7Y2345 PIN Caterpillar parts
325, 325 L, 325 LN, 325B, 325B L, M325B
Rating:
Alternative (cross code) number:
CA7Y2345
7Y-2345
7Y2345
CA7Y2345
7Y-2345
7Y2345
Weight: 91 pounds 41 kg.
EXCAVATOR, WHEELED EXCAVATOR,
Related part:
7Y2345
PIN-YM
3940211
CL
You can buy:
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$444.82
11 Feb 2023
US: QUALITY PARTS
Made to fit 7Y2345 Pin Part 7Y2345, 7Y-2345 CAT New Aftermarket
G&T Engine Parts 7Y2345 Made to fit 7Y2345 CAT || Meets OEM Specs for Fit and Performance || This is a new item CAT Pin Part 7Y2345, 7Y-2345 || Items are sold by part number only. Picture is for illustration purposes and the part or parts may be different in color or quantity. || Use of any OEM manufacturer name is not intended to represent any relationship between the two companies, instead it indicates that we sell replacement parts that are compatible with OEM components.
G&T Engine Parts 7Y2345 Made to fit 7Y2345 CAT || Meets OEM Specs for Fit and Performance || This is a new item CAT Pin Part 7Y2345, 7Y-2345 || Items are sold by part number only. Picture is for illustration purposes and the part or parts may be different in color or quantity. || Use of any OEM manufacturer name is not intended to represent any relationship between the two companies, instead it indicates that we sell replacement parts that are compatible with OEM components.
Compatible equipment models: 7Y2345:
Information:
System Operation Description:Most electrical faults are caused by poor connections. The following procedure will assist in detecting faults with connectors and with wiring. If a fault is found, correct the condition and verify that the fault is resolved.Intermittent electrical faults are sometimes resolved by disconnecting and reconnecting connectors. Check for diagnostic codes immediately before disconnecting a connector. Also check for diagnostic codes after reconnecting the connector. If the status of a diagnostic code is changed due to disconnecting and reconnecting a connector, there are several possible reasons. The likely reasons are loose terminals, improperly crimped terminals, moisture, corrosion, and inadequate mating of a connection.Follow these guidelines:
Always use a breakout harness for a voltmeter probe or a test light. Never break the insulation of a wire in order to access a circuit for measurements.
If a wire is cut, always install a new terminal for the repair.
The connection of any electrical equipment and the disconnection of any electrical equipment may cause an explosion hazard which may result in injury or death. Do not connect any electrical equipment or disconnect any electrical equipment in an explosive atmosphere.
Test Step 1. Check Connectors for Moisture and Corrosion
Inspect all the harnesses. Ensure that the routing of the wiring harness allows the wires to enter the face of each connector at a perpendicular angle. Otherwise, the wire will deform the seal bore. This condition will create a path for the entrance of moisture. Verify that the seals for the wires are sealing correctly.
Ensure that the sealing plugs are in place. If any of the plugs are missing, replace the plug. Ensure that the plugs are inserted correctly into the connector.
Illustration 1 g01885653
(1) Seal for a three-pin connector (typical example)
Disconnect the suspect connector and inspect the connector seal. Ensure that the seal is in good condition. If necessary, replace the connector.
Thoroughly inspect the connectors for evidence of moisture entry. Note: Some minor seal abrasion on connector seals is normal. Minor seal abrasion will not allow the entry of moisture.If moisture or corrosion is evident in the connector, the source of the moisture entry must be identified and repaired. If the source of the moisture entry is not repaired, the fault will recur. Simply drying the connector will not rectify the fault. Check the following items for the possible moisture entry path:
Missing seals
Incorrectly installed seals
Nicks in exposed insulation
Improperly mated connectorsMoisture can also travel to a connector through the inside of a wire. If moisture is found in a connector, thoroughly check the connector harness for damage. Also check other connectors that share the harness for moisture.Note: The ECM is a sealed unit. If moisture is found in an ECM connector, the ECM is not the source of the moisture. Do not replace the ECM.Expected Result:The harness, connectors, and seals are in good condition. There is no evidence of moisture in the connectors.Results:
The harness, connectors, and seals are in good condition - Proceed to Test Step 2.
A fault has been found with the harness or the connectors. - Repair:
Always use a breakout harness for a voltmeter probe or a test light. Never break the insulation of a wire in order to access a circuit for measurements.
If a wire is cut, always install a new terminal for the repair.
The connection of any electrical equipment and the disconnection of any electrical equipment may cause an explosion hazard which may result in injury or death. Do not connect any electrical equipment or disconnect any electrical equipment in an explosive atmosphere.
Test Step 1. Check Connectors for Moisture and Corrosion
Inspect all the harnesses. Ensure that the routing of the wiring harness allows the wires to enter the face of each connector at a perpendicular angle. Otherwise, the wire will deform the seal bore. This condition will create a path for the entrance of moisture. Verify that the seals for the wires are sealing correctly.
Ensure that the sealing plugs are in place. If any of the plugs are missing, replace the plug. Ensure that the plugs are inserted correctly into the connector.
Illustration 1 g01885653
(1) Seal for a three-pin connector (typical example)
Disconnect the suspect connector and inspect the connector seal. Ensure that the seal is in good condition. If necessary, replace the connector.
Thoroughly inspect the connectors for evidence of moisture entry. Note: Some minor seal abrasion on connector seals is normal. Minor seal abrasion will not allow the entry of moisture.If moisture or corrosion is evident in the connector, the source of the moisture entry must be identified and repaired. If the source of the moisture entry is not repaired, the fault will recur. Simply drying the connector will not rectify the fault. Check the following items for the possible moisture entry path:
Missing seals
Incorrectly installed seals
Nicks in exposed insulation
Improperly mated connectorsMoisture can also travel to a connector through the inside of a wire. If moisture is found in a connector, thoroughly check the connector harness for damage. Also check other connectors that share the harness for moisture.Note: The ECM is a sealed unit. If moisture is found in an ECM connector, the ECM is not the source of the moisture. Do not replace the ECM.Expected Result:The harness, connectors, and seals are in good condition. There is no evidence of moisture in the connectors.Results:
The harness, connectors, and seals are in good condition - Proceed to Test Step 2.
A fault has been found with the harness or the connectors. - Repair:
Caterpillar parts catalog:
Parts pin Caterpillar catalog:
1894150
PIN AS
322B LN, 322C, 325B L, 325C, 328D LCR, 330B L, 330C, 330C L, 385B, 385C L
322B LN, 322C, 325B L, 325C, 328D LCR, 330B L, 330C, 330C L, 385B, 385C L
1894148
PIN AS
322B LN, 322C, 325B L, 325C, 328D LCR, 330B L, 330C, 330C L, 385B, 385C L, GSH15-60, GSH22B, GSH9
322B LN, 322C, 325B L, 325C, 328D LCR, 330B L, 330C, 330C L, 385B, 385C L, GSH15-60, GSH22B, GSH9
1883065
PIN-TRACK MASTER
320C, 322C, 322C FM, 323D LN, 323D SA, 325B L, 325C, 325C FM, 325C L, 325D, 325D L, 325D MH, 329D, 329D L, 329D LN, 330C, 330C L, 330D, 330D L, 336D L, 336D LN, 336E, 345C, 345D, 349D L, OEMS
320C, 322C, 322C FM, 323D LN, 323D SA, 325B L, 325C, 325C FM, 325C L, 325D, 325D L, 325D MH, 329D, 329D L, 329D LN, 330C, 330C L, 330D, 330D L, 336D L, 336D LN, 336E, 345C, 345D, 349D L, OEMS
2448504
PIN AS
320C, 320D, 320D L, 320D LN, 320D LRR, 320D2 L, 320E LN, 320E LRR, 321C, 321D LCR, 322C, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 324D L, 325B L, 325C, 325D, 325D L, 329D L, 330D L, 336D L, 345C L, ...
320C, 320D, 320D L, 320D LN, 320D LRR, 320D2 L, 320E LN, 320E LRR, 321C, 321D LCR, 322C, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 324D L, 325B L, 325C, 325D, 325D L, 329D L, 330D L, 336D L, 345C L, ...
6Y0850
PIN-TRACK MASTER
322C FM, 323E L, 324D FM, 324D FM LL, 325, 325 L, 325 LN, 325B L, 325C, 325C FM, 325D, 325D L, 325D MH, 329D, 329D L, 329D LN, 329E, 329E L, 329E LN, OEMS
322C FM, 323E L, 324D FM, 324D FM LL, 325, 325 L, 325 LN, 325B L, 325C, 325C FM, 325D, 325D L, 325D MH, 329D, 329D L, 329D LN, 329E, 329E L, 329E LN, OEMS
4I6626
PIN
115, 324D, 324D L, 324D LN, 324E, 324E L, 324E LN, 325B L, 325C, 325D, 325D L, 326D L, 328D LCR, 329D, 329D L, 329D LN, 329E, 329E L, 329E LN, 330, 330 FM L, 330 L, 330B, 330B L, 330C, 330C L, 330D, 3...
115, 324D, 324D L, 324D LN, 324E, 324E L, 324E LN, 325B L, 325C, 325D, 325D L, 326D L, 328D LCR, 329D, 329D L, 329D LN, 329E, 329E L, 329E LN, 330, 330 FM L, 330 L, 330B, 330B L, 330C, 330C L, 330D, 3...
7Y6617
PIN
325, 325 L
325, 325 L
7Y6618
PIN
325, 325 L
325, 325 L
0876372
PIN
325B L, 330, 330 FM L, 330 L, 330B, 330B L, 345B II, 345B II MH, W330B, W345B II
325B L, 330, 330 FM L, 330 L, 330B, 330B L, 345B II, 345B II MH, W330B, W345B II
1054739
PIN
325B L, 330, 330 FM L, 330B L
325B L, 330, 330 FM L, 330B L
1152775
PIN AS
325B, 325B L, M325B
325B, 325B L, M325B
4I4617
PIN AS
325, 325 FM L, 325 L, 325 LN
325, 325 FM L, 325 L, 325 LN
1653917
PIN
375
375
1235339
PIN AS
350, 350 L, 375
350, 350 L, 375
2Y2954
PIN
120B
120B
4D8005
PIN
16
16
211A
PIN
16
16
5D8070
PIN
16
16
2861364
PIN AS
330D
330D
2256582
PIN AS
330D
330D
5I3301
PIN AS
330, 330 FM L, 330 L, 330B, 330B L, 330C FM, 330D FM, 345B II, 345B L, 345C, 350 L, W330B
330, 330 FM L, 330 L, 330B, 330B L, 330C FM, 330D FM, 345B II, 345B L, 345C, 350 L, W330B
2086487
PIN AS
325C
325C
2086486
PIN AS
325C
325C
8E6093
PIN-TRACK
345B, 350, 350 L
345B, 350, 350 L