8D4766 PIN-CYLINDER Caterpillar parts
120, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
Rating:
Alternative (cross code) number:
CA8D4766
8D-4766
8D4766
CA8D4766
8D-4766
8D4766
Weight: 3 pounds 1 kg.
MOTOR GRADER,
Related part:
8D4766
PIN-CYLINDER-YM
3658832
CL
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$32.18
24 Jan 2024
US: FinditParts Inc
8D4766 - PLATE (L.H.) fits Caterpillar (CAT)
BLUMAQ 8D4766 - PLATE (L.H.) fits Caterpillar (CAT)
BLUMAQ 8D4766 - PLATE (L.H.) fits Caterpillar (CAT)
Compatible equipment models: 8D4766:
Information:
Illustration 1 g02118437
(1) Display screen
(2) F4 Soft key
(3) F3 Soft key
(4) F2 Soft key
(5) F1 Soft key
(6) Control key
(7) AC overview key
(8) Engine overview key
(9) Main menu
(10) Warning Indicator lamp (yellow)
(11) Alarms acknowledge key and silence key
(12) Shutdown Indicator lamp (red)
(13) Event reset key
(14) Event log key
(15) Run key
(16) Auto key
(17) Stop key
(18) Escape key
(19) Up key
(20) Right key
(21) OK key
(22) Down key
(23) Left key General Information
The main component of the Electronic Modular Control Panel 4.3/4.4 ( EMCP 4.3/4.4) is the electronic control module (ECM). This section discusses the display, keys, and indicators on the control system panel of the ECM. The EMCP 4.3/4.4 panel is used for monitoring and controlling many of the generator set functions. Some of the functions include:
Sending start and stop signals to the engine
Providing visual and audible indications when warning or shutdown events occur
Displaying engine information and AC generator set information
Displaying Suspect Parameter Number (SPN) and Failure Mode Identifier (FMI) information for events
Programming set points for the standard EMCP 4.3/4.4 (The set points for optional modules are set with the use of Cat ET.)
Annunciator configuration is done within the EMCP 4.3/4.4ECM Front Panel Components
The following components can be found on the front panel of the ECM:
Information Display
Alarm Indicators
Alarm Acknowledge/Silence Key
Event Reset Key
Function Keys
Navigation Keys
System Overview KeysInformation Display
(1) Display Screen - Information from the EMCP 4 is displayed on the display screen. This screen is used for the following programming and display functions.
Displaying AC parameter information of the generator set
Displaying engine parameter information of the generator set
Programming set points for the generator
Displaying engine event information
Displaying event codes from other modules
Programming the display preferences of the EMCP 4.3/4.4
Changing password levels of the EMCP 4.3/4.4Alarm Acknowledge/Silence Key
(10) Alarm Acknowledge/Silence Key - Pressing the alarm acknowledge/silence key will cause the horn relay output to turn off and silence the horn. Pressing the key will also cause any yellow or red flashing lights to turn off or to become solid depending on the active status of the alarms. The alarm acknowledge/silence key may also be configured to send out a global alarm silence on the J1939 Data Link which will silence horns on annunciators. However, other modules must be configured in order to listen to the global acknowledge.Event Reset Key
(11) Event Reset Key - The event reset button will clear all inactive fault conditions.Alarm Indicators
Yellow Warning Light - The yellow warning light (10) is located directly above the alarm acknowledge/silence key (11). A flashing yellow light indicates that there are unacknowledged active warnings. A solid yellow light indicates that there are acknowledged warnings active. If there are any active warnings, the yellow light will change from flashing yellow to solid yellow after the alarm acknowledge/silence key is pressed. If there are no longer any active warnings, the yellow light will turn off after the alarm acknowledge/silence key is pressed.Red Shutdown Light - The red shutdown (12) light is located directly above the event reset key (13). A flashing red light indicates that there are unacknowledged active shutdown events. A
Cat SIS web machinery list:
Parts pin Caterpillar catalog:
4D7358
PIN
120, 120B, 12E, 12F, 140, 140B, 14E
120, 120B, 12E, 12F, 140, 140B, 14E
3D0444
PIN
120, 120B, 12E, 12F, 140, 140B, 14E
120, 120B, 12E, 12F, 140, 140B, 14E
8B9787
PIN
120, 120B, 12E, 12F, 140, 140B, 14E, 16
120, 120B, 12E, 12F, 140, 140B, 14E, 16
2D5961
PIN
120, 120B, 12E, 140, 140B
120, 120B, 12E, 140, 140B
3F6333
PIN
120, 120B, 12E
120, 120B, 12E
3B6706
PIN
120, 120B, 12E
120, 120B, 12E
8D7167
PIN
12G, 130G, 140G
12G, 130G, 140G
8D7095
PIN
12G, 130G
12G, 130G
8D7096
PIN
12G, 130G
12G, 130G
2G8629
PIN
12G, 130G
12G, 130G
2G5723
PIN
130G
130G
2G5724
PIN
130G
130G
2G8617
PIN
12G, 130G, 140G, 160G
12G, 130G, 140G, 160G
2G8621
PIN
12G, 130G, 140G, 160G
12G, 130G, 140G, 160G
5D8161
PIN
120, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12E, 12F, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140, 140B, 140G, 140H, 140H ES, 140H NA, 140K...
120, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12E, 12F, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140, 140B, 140G, 140H, 140H ES, 140H NA, 140K...
9D1531
PIN
120G, 120H, 120H ES, 120H NA, 135H, 135H NA
120G, 120H, 120H ES, 120H NA, 135H, 135H NA
9D1532
PIN
120G
120G
6G3239
PIN
120G, 12G, 130G, 140G, 14G, 160G, 16G, 24H
120G, 12G, 130G, 140G, 14G, 160G, 16G, 24H
1187307
PIN-TRACK MASTER
330B L, OEMS
330B L, OEMS
9J0090
PIN
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 130G, 135H, 135H NA, 140G
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 130G, 135H, 135H NA, 140G
8D4689
PIN
12G, 130G, 140G, 160G
12G, 130G, 140G, 160G
8D1784
PIN
12G, 130G, 140G, 160G
12G, 130G, 140G, 160G
8D9786
PIN
12G, 130G, 140G, 160G
12G, 130G, 140G, 160G
6G2231
PIN
12G, 130G, 140G, 14G, 160G, 16G
12G, 130G, 140G, 14G, 160G, 16G