0878426 PIPE Caterpillar parts
E240C, EL240B
Rating:
Alternative (cross code) number:
CA0878426
087-8426
0878426
CA0878426
087-8426
0878426
Weight: 0.30 pounds 0 kg.
EXCAVATOR,
Information:
Introduction
Use the following procedure in order to measure the case drain of the travel motors.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Required Tools
Illustration 1 g02148680
Tooling group "D"
Illustration 2 g03269576
Track Block (G)
Table 2
Tool Item Qty Part Number Description
D D1 1 6V-7788 Flow Meter
5 to 60 L/min (2 to 15 US gpm)
D2 1 8C-6874 Connector
D3 2 6V-9746 O-Ring Seal
D4 1 124-1921 Permanent Coupling
D5 1 122-6872 Bulk Hydraulic Hose
D6 1 124-2153 Permanent Coupling
F 1 311-1362 Vacuum Cap
G 1 418-3612 Track Block Machine Preparation
Position the machine on level ground.
Illustration 3 g03330350
Sprocket (left travel)
(G) Track Block
(1) Sprocket
Place track block (G) in sprocket (1) in order to block forward left travel. Refer to Illustration 3.
Stop the engine.
Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "System Pressure - Release".
Attach 311-1362 Vacuum Cap onto the hydraulic tank. Attach an air supply hose onto the assembly. Apply 276 to 414 kPa (40 to 60 psi). This procedure will pull a vacuum on the hydraulic system.
Illustration 4 g02155707
Flow Meter Tool Layout
Tooling (D)
( 2) Case drain hose
(3) Connector
(4) Travel motor
Install the following tools in accordance with the flow meter tool layout. Refer to Illustration 4.
Disconnect case drain hose (2) from connector (3).
Connect the flow meter assembly (D) between connector (3) and case drain hose (2). Note: Correct orientation of the flow meter is necessary. The oil flows from travel motor (4) to case drain hose (2).
Remove 311-1362 Vacuum Cap. Test Procedure
Start the engine.
Increase the hydraulic oil temperature to 55° 5°C (131° 9°F).
Place the machine controls at the following settings: engine speed dial "10" and AEC switch OFF. Refer to Testing and Adjusting, "Engine Performance - Test (Engine Speed)" for engine rpm settings.
Place the hydraulic activation control lever in the UNLOCKED position.
Move the left travel lever to full FORWARD position and check the flow of oil through the flow meter. Refer to Table 1.
Remove track block (G) from sprocket (1).
Move the left travel lever in order to reposition the travel motor.
Place track block (G) in sprocket (1) in order to block forward left travel.
Repeat Steps 5 through 8 in order to obtain three measurements of case drain oil.
Use the following procedure in order to measure the case drain of the travel motors.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Required Tools
Illustration 1 g02148680
Tooling group "D"
Illustration 2 g03269576
Track Block (G)
Table 2
Tool Item Qty Part Number Description
D D1 1 6V-7788 Flow Meter
5 to 60 L/min (2 to 15 US gpm)
D2 1 8C-6874 Connector
D3 2 6V-9746 O-Ring Seal
D4 1 124-1921 Permanent Coupling
D5 1 122-6872 Bulk Hydraulic Hose
D6 1 124-2153 Permanent Coupling
F 1 311-1362 Vacuum Cap
G 1 418-3612 Track Block Machine Preparation
Position the machine on level ground.
Illustration 3 g03330350
Sprocket (left travel)
(G) Track Block
(1) Sprocket
Place track block (G) in sprocket (1) in order to block forward left travel. Refer to Illustration 3.
Stop the engine.
Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "System Pressure - Release".
Attach 311-1362 Vacuum Cap onto the hydraulic tank. Attach an air supply hose onto the assembly. Apply 276 to 414 kPa (40 to 60 psi). This procedure will pull a vacuum on the hydraulic system.
Illustration 4 g02155707
Flow Meter Tool Layout
Tooling (D)
( 2) Case drain hose
(3) Connector
(4) Travel motor
Install the following tools in accordance with the flow meter tool layout. Refer to Illustration 4.
Disconnect case drain hose (2) from connector (3).
Connect the flow meter assembly (D) between connector (3) and case drain hose (2). Note: Correct orientation of the flow meter is necessary. The oil flows from travel motor (4) to case drain hose (2).
Remove 311-1362 Vacuum Cap. Test Procedure
Start the engine.
Increase the hydraulic oil temperature to 55° 5°C (131° 9°F).
Place the machine controls at the following settings: engine speed dial "10" and AEC switch OFF. Refer to Testing and Adjusting, "Engine Performance - Test (Engine Speed)" for engine rpm settings.
Place the hydraulic activation control lever in the UNLOCKED position.
Move the left travel lever to full FORWARD position and check the flow of oil through the flow meter. Refer to Table 1.
Remove track block (G) from sprocket (1).
Move the left travel lever in order to reposition the travel motor.
Place track block (G) in sprocket (1) in order to block forward left travel.
Repeat Steps 5 through 8 in order to obtain three measurements of case drain oil.
Caterpillar parts catalog:
Parts pipe Caterpillar catalog:
4I9496
PIPE, R.H.
E240C
E240C
4I9494
PIPE, R.H.
E240C
E240C
4I9504
PIPE, R. H.
E240C
E240C
4I9503
PIPE, L. H.
E240C
E240C
4I9499
PIPE, L. H.
E240C
E240C
4I9501
PIPE, L. H.
E240C
E240C
4I9502
PIPE, R. H.
E240C
E240C
4I9500
PIPE, R. H.
E240C
E240C
7I2443
PIPE
E240C
E240C
5I9394
PIPE
E240C
E240C
5I9395
PIPE
E240C
E240C
5I9396
PIPE
E240C
E240C
0858539
PIPE
E240C, EL240B
E240C, EL240B
0858538
PIPE
E240C, EL240B
E240C, EL240B
4I9365
PIPE
E240C, EL240B
E240C, EL240B
1R8146
PIPE
E240C, EL240B
E240C, EL240B
1R8003
PIPE
E240C, EL240B
E240C, EL240B
0998329
PIPE
EL240B
EL240B
0996157
PIPE
EL240B
EL240B
0996158
PIPE
E240C, EL240B
E240C, EL240B
1R7722
PIPE
E240C, EL240B
E240C, EL240B
1R7723
PIPE
E240C, EL240B
E240C, EL240B
1R7721
PIPE
E240C, EL240B
E240C, EL240B
1R9898
PIPE
E240C, EL240B
E240C, EL240B