0967346 PIPE Caterpillar parts
E110, E120
Rating:
Alternative (cross code) number:
CA0967346
096-7346
0967346
CA0967346
096-7346
0967346
Weight: 0.23 pounds 0 kg.
EXCAVATOR,
Information:
Illustration 1 g00594692
Schematic for the temperature sensor (transmission oil)
This diagnostic code is recorded when the main display module reads a low sensor signal. As a result of this diagnostic code the corresponding gauge will indicate an abnormally high value. The possible causes are listed below:
The sensor has failed.
The signal circuit in the machine harness is shorted to ground.
The main display module has failed.Note: The main display module is unable to determine when a sensor is open or a sensor signal harness is open. Also, the main display module is unable to determine when the resistance is too high. This condition is recognized as a gauge that has an indicator at the far left side of the scale.Service Notes: Ensure that the desired diagnostic code is on hold. Ensure that the diagnostic code indicator shows "SERV CODE". The schematic that is shown above represents a typical installation of the component. Verify the connector contact and wire numbers by using the Electrical System Schematic for the machine that is being serviced. Test Step 1. CHECK THE MAIN DISPLAY MODULE AND THE HARNESS.
Turn the disconnect switch and the key start switch to the ON position.
The diagnostic code indicator should show "SERV CODE".
Disconnect the machine harness from the sensor that is causing the problem.
Observe the diagnostic code indicator. Expected Result:The diagnostic code indicator is ON.Results:
YES - The diagnostic code indicator stays ON. The harness wiring or the main display module has failed. Proceed to test step 2.
NO - The diagnostic code indicator turns OFF. The sensor has failed.Repair: Replace the sensor.STOPTest Step 2. CHECK THE SIGNAL WIRE FOR A SHORT TO GROUND.
The machine harness remains disconnected from the sensor.
The disconnect switch and the key start switch remain in the ON position.
At the machine harness connector for the sensor, measure the voltage. Measure the voltage from contact "C" (wire 443-YL(Yellow)) and frame ground. Expected Result:The voltage that is measured is within one of the following specifications.Results:
6.0 0.5 DCV - The voltage is 6.0 0.5 DCV. The voltage is correct. Verify that the diagnostic code is still present. Repair: It is unlikely that the main display module has failed. Exit this procedure and perform this procedure again. Also, recheck if the diagnostic code indicator is illuminated for this diagnostic code. If the cause of the diagnostic code is not found, replace the main display module. See Testing and Adjusting, "Module - Replace".STOP
LESS THAN 0.5 DCV - The voltage
Caterpillar parts catalog:
Parts pipe Caterpillar catalog:
0954563
PIPE
E120, E140
E120, E140
0967354
PIPE
E110, E120, E140
E110, E120, E140
0967742
PIPE, L. H.
E120
E120
0938911
PIPE
E110, E120
E110, E120
0957306
PIPE
E120
E120
0994062
PIPE
E110, E120
E110, E120
0994076
PIPE
E120
E120
0861140
PIPE
E120
E120
0967789
PIPE, R. H.
E120
E120
0947348
PIPE NO. 2
E110, E70, E70B
E110, E70, E70B
0969202
PIPE
E110
E110
0993320
PIPE, L. H.
E110
E110
0967347
PIPE
E110, E120
E110, E120
0962007
PIPE
E120
E120
0962009
PIPE
E120
E120
0962010
PIPE
E120
E120
0962008
PIPE
E120
E120
0967338
PIPE
E110, E120
E110, E120
0967329
PIPE
E110, E120
E110, E120
0967345
PIPE
E110, E120
E110, E120
0957305
PIPE
E110, E120
E110, E120
0967348
PIPE
E110, E120
E110, E120
0967349
PIPE
E110, E120
E110, E120
0938911
PIPE
E110, E120
E110, E120