1013628 PIPE-AIR INLET Caterpillar parts
Rating:
Alternative (cross code) number:
CA1013628
101-3628
1013628
CA1013628
101-3628
1013628
Weight: 4 pounds 1 kg.
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$44.40
18 Jul 2023
US: Technical Preci
Technical Precision Replacement for Club CAR 1013628 Battery
Technical Precision Replacement For CLUB CAR 1013628 || Unit per sale:1
Technical Precision Replacement For CLUB CAR 1013628 || Unit per sale:1
$44.40
29 Apr 2023
US: Technical Preci
Replacement For CLUB CAR 1013628 by Technical Precision Battery
Technical Precision Replacement For CLUB CAR 1013628 || Unit per sale:1
Technical Precision Replacement For CLUB CAR 1013628 || Unit per sale:1
$154.99
04 Jun 2021
US: Louis Powerspor
Polaris 2002 Xpedition Flange & Sleeve 1234 984 32 2 1013628 New Oem
Polaris New OEM Polaris Flange & Sleeve 1234 984 32 2 || OEM Part Number: 1013628 || Item only fits specific models listed. The picture could be generic. || Message us with VIN/HULL for fast fitment verification.
Polaris New OEM Polaris Flange & Sleeve 1234 984 32 2 || OEM Part Number: 1013628 || Item only fits specific models listed. The picture could be generic. || Message us with VIN/HULL for fast fitment verification.
Information:
Illustration 1 g02079373
Schematic of the "Swing Priority" SolenoidThis diagnostic code is associated with the "Swing Priority" Solenoid. The FMI 05 diagnostic code means that the Machine ECM has determined that the current is below normal.The possible causes of this diagnostic code are listed below:
The energizer circuit of the solenoid for the modulating valve is open.
The return circuit of the modulating valve is open.
The solenoid has failed.
The Machine ECM has failed. A failure of the ECM is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 3633 FMI 05 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code is active, the ECM will turn off the current to the failed solenoid.Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the solenoid with the active diagnostic code from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire K921-GY) to contact 2 (wire L968-OR).
Observe the status of the CID 3633 FMI 05 diagnostic code.Expected Result:The CID 3633 FMI 05 diagnostic code remains active. Results:
YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.
NO - The diagnostic is no longer active. The solenoid has failed.Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the Machine ECM.
The jumper wire that was installed in the previous test remains in place.
At the machine harness connector, measure the resistance from signal contact J2-28 (wire K921-GY) to contact J2-19 (wire L968-OR).Expected Result:Both resistances are less than 5.0 ohms.Results:
OK - Both resistances are less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Either resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: The open is in wire K921-GY or in wire L968-OR of the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS
Inspect the contacts of the harness connectors and clean the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 3633 FMI 05 diagnostic code.Expected Result:The CID 3633 FMI 05 diagnostic code is active.Results:
YES - The CID 3633 FMI 05 diagnostic code is active. The diagnostic code has not been corrected. The Machine ECM may have failed.Repair: A failure of the Machine ECM is unlikely.
Parts pipe Caterpillar catalog:
1010390
PIPE A
Caterpillar
Caterpillar
1009472
PIPE
Caterpillar
Caterpillar
1009465
PIPE PLUG
Caterpillar
Caterpillar
1007298
PIPE AS
Caterpillar
Caterpillar
1005123
PIPE
Caterpillar
Caterpillar
0T0905
PIPE
Caterpillar
Caterpillar
1015639
PIPE
Caterpillar
Caterpillar
1015638
PIPE
Caterpillar
Caterpillar
1015417
PIPE
Caterpillar
Caterpillar
1015224
PIPE
Caterpillar
Caterpillar
1015214
PIPE
Caterpillar
Caterpillar
1015195
PIPE
Caterpillar
Caterpillar