AVSPARE.COM
parts catalog

PIPE 1048266 - Caterpillar


1048266 PIPE Caterpillar parts
Rating:
86
Alternative (cross code) number:
CA1048266
104-8266
1048266
Caterpillar 1048266 PIPE

Buy PIPE 1048266 Caterpillar genuine, new aftermarket tractor parts with delivery

  For full view, you need register

Information:


Illustration 22 g06135426
Cat Grade Control "CGC Calibrations" screen
Boom Sensor Calibration
The Boom Sensor Calibration calibrates the Boom Rotary Position Sensor for the Cat Grade Control system. This sensor may be calibrated at any point after the Body Tilt Sensor Calibration and Front Linkage Position Sensor Calibration. The Boom Sensor Calibration can be started by navigating on the onboard 300E Monitor to Menu > Service > Grade Control System > CGC Calibrations > Boom Sensor > NOT USED. A calibration will only successfully complete if a "NOT USED" location in the table is selected. The accuracy of the calibration depends on the accuracy of the fixed linkage dimensions entered into the Machine Dimension settings, the accuracy of the completed Body Tilt Sensor Calibration, and the accuracy of the calibration input measurement entered. The calibration process will require the vertical height difference between Pin B and Pin A be entered. This calibration should be repeated a minimum of three times at various places throughout the boom range of motion.
Illustration 23 g06135428
Cat Grade Control "Boom Sensor" calibration screen
Note: Only calibrating the sensor at one linkage position or over a limited range of motion may not lead to optimum system accuracy. Calibrating the sensor over the entire working range of the linkage will average out slight sensor misalignment and lead to the highest accuracy. The calibration offset angles produced from this calibration should be relatively repeatable throughout the range of motion of the machine for aligned sensors. It is not necessary for all offset values to be within 0.4 degrees for Cat Grade Control machines. However, if the range of calibration offset values exceed 1 degree, the sensor alignment should be verified and the sensor movement should be examined for movement obstructions or interference.Calibrating throughout the entire working range of the Boom is difficult to achieve without digging a hole so a reduced calibration range is acceptable for the Boom sensor. The Boom sensor is less prone to error than the Stick sensor and it is common to see a range in calibration values less than 0.2 degrees.
Illustration 24 g06135429Stick Sensor Calibration
The Stick Sensor Calibration calibrates the Stick Rotary Position Sensor for the Cat Grade Control system. This sensor may be calibrated at any point after the Body Tilt Sensor Calibration and Front Linkage Position Sensor Calibration. The Stick Sensor Calibration can be started by navigating on the onboard 300E Monitor to Menu > Service > Grade Control System > CGC Calibrations > Stick Sensor > NOT USED. A calibration will only successfully complete if a "NOT USED" location in the table is selected. The accuracy of the calibration depends on the accuracy of the fixed linkage dimensions entered into the Machine Dimension settings, and the accuracy of the calibration input measurement entered. The calibration process will require the straight-lined (slope) distance between Pin A and Pin G along the centerline of the front linkage to be entered. This calibration should be repeated a minimum of three times at various places throughout the stick range of


Parts pipe Caterpillar catalog:

Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.