Information:
Table lists the default menu items for a Laser AccuGrade system.
Table 2
Setup Menu - Laser Configuration Menu Items    
Menu Item     Description    
Bench     Automatically positions both laser receivers to within
1.5 mm (0.0591 inch) of the center of the laser beam.    
Vertical Setup     Allows the operator to change the method of guidance. The following list includes some of the methods:     3D, 1 Point Center
3D, 1 Point Focus
3D, 2 Point Tips    
Increment Switch Adjustment (1)     The Increment Switch Adjustment dialog allows you to set the amount that each press of the vertical offset switch increases or decreases the vertical offset and/or the amount by which the target cross slope adjustment will increase or decrease the target cross slope. Refer to Operation and Maintenance Manual, "Increment Switch - Set" for additional information.    
"Lightbar Scale"     The Light Bar Scales dialogs set the vertical and horizontal tolerances that apply to the LEDs on the Light Bars. Refer to Operation and Maintenance Manual, "Light Bar Scale - Set" for additional information.    
Display and Lightbar Brightness     The Display and Light Bar Brightness dialog sets the brightness of the Display and Light Bars. By default the dialog is only available in the "Setup Menu – Configuration". Refer to Operation and Maintenance Manual, "Brightness (Display and Light Bar) - Set" for additional information.    
Calibrate Sensors     Allows the operator calibrate the angle sensors that are install in the AccuGrade System.    
Valve Speed     Allows the operator to adjust the valve speed for the lift valve and the tilt valve.    
Text Items (1)     Text Items allows you to customize the text items on the Display in order to suit your requirements. Refer to for additional information.    
Beeper (1)     The beeper can be configured in order to provide an audible signal when various events occur. Refer to Operation and Maintenance Manual, "Beeper - Set" for additional information.
   
Save Settings     Allows the operator to save the machine settings and the display settings to the Data Card.    
Restore Settings     Use the Restore Settings dialog in order to restore previously saved Display settings or machine settings.    
Diagnostics     The software for the AccuGrade System displays diagnostic information about the devices the software detects and also the GPS Receiver. Refer to Operation and Maintenance Manual, "Diagnostics - View" for additional information.    
( 1 ) This item is not a default setting. Contact your site manager for access to this item.In order to access the "Setup Menu" dialog complete the following steps:
Illustration 1 g01300176
Press the "Menu" key.A screen that is similar to Illustration 1 will appear.Note: Changes that are made to the "Setup Menu" options take effect as soon as you exit the "Setup Menu" dialog.Working with the Setup Menu
Press the Down Arrow or the Up Arrow in order to scroll through the available options. Press the "OK" key in order to select the appropriate item.Within any of the "Setup Menu
Table 2
Setup Menu - Laser Configuration Menu Items    
Menu Item     Description    
Bench     Automatically positions both laser receivers to within
1.5 mm (0.0591 inch) of the center of the laser beam.    
Vertical Setup     Allows the operator to change the method of guidance. The following list includes some of the methods:     3D, 1 Point Center
3D, 1 Point Focus
3D, 2 Point Tips    
Increment Switch Adjustment (1)     The Increment Switch Adjustment dialog allows you to set the amount that each press of the vertical offset switch increases or decreases the vertical offset and/or the amount by which the target cross slope adjustment will increase or decrease the target cross slope. Refer to Operation and Maintenance Manual, "Increment Switch - Set" for additional information.    
"Lightbar Scale"     The Light Bar Scales dialogs set the vertical and horizontal tolerances that apply to the LEDs on the Light Bars. Refer to Operation and Maintenance Manual, "Light Bar Scale - Set" for additional information.    
Display and Lightbar Brightness     The Display and Light Bar Brightness dialog sets the brightness of the Display and Light Bars. By default the dialog is only available in the "Setup Menu – Configuration". Refer to Operation and Maintenance Manual, "Brightness (Display and Light Bar) - Set" for additional information.    
Calibrate Sensors     Allows the operator calibrate the angle sensors that are install in the AccuGrade System.    
Valve Speed     Allows the operator to adjust the valve speed for the lift valve and the tilt valve.    
Text Items (1)     Text Items allows you to customize the text items on the Display in order to suit your requirements. Refer to for additional information.    
Beeper (1)     The beeper can be configured in order to provide an audible signal when various events occur. Refer to Operation and Maintenance Manual, "Beeper - Set" for additional information.
   
Save Settings     Allows the operator to save the machine settings and the display settings to the Data Card.    
Restore Settings     Use the Restore Settings dialog in order to restore previously saved Display settings or machine settings.    
Diagnostics     The software for the AccuGrade System displays diagnostic information about the devices the software detects and also the GPS Receiver. Refer to Operation and Maintenance Manual, "Diagnostics - View" for additional information.    
( 1 ) This item is not a default setting. Contact your site manager for access to this item.In order to access the "Setup Menu" dialog complete the following steps:
Illustration 1 g01300176
Press the "Menu" key.A screen that is similar to Illustration 1 will appear.Note: Changes that are made to the "Setup Menu" options take effect as soon as you exit the "Setup Menu" dialog.Working with the Setup Menu
Press the Down Arrow or the Up Arrow in order to scroll through the available options. Press the "OK" key in order to select the appropriate item.Within any of the "Setup Menu
Caterpillar parts catalog:
Parts pipe Caterpillar catalog:
2117044
PIPE AS
315C, 318C, 319C
315C, 318C, 319C
1756173
PIPE
314D CR, 314D LCR, 314E CR, 314E LCR, 318C, 319C, 320C, 320D FM RR, 320D LRR, 320D RR, 320E LN, 320E LRR, 320E RR, 321C, 321D LCR, 323E L, 324E, 324E L, 324E LN, 328D LCR, 329E, 329E L, 329E LN, 336E,...
314D CR, 314D LCR, 314E CR, 314E LCR, 318C, 319C, 320C, 320D FM RR, 320D LRR, 320D RR, 320E LN, 320E LRR, 320E RR, 321C, 321D LCR, 323E L, 324E, 324E L, 324E LN, 328D LCR, 329E, 329E L, 329E LN, 336E,...
2109944
PIPE AS
318C
318C
2109948
PIPE AS
318C
318C
2109946
PIPE AS
318C
318C
2026912
PIPE AS
318C
318C
2084122
PIPE
312C, 315C
312C, 315C
2056755
PIPE AS
315C
315C
2056770
PIPE AS
315C
315C
2175606
PIPE AS
315C
315C
2023610
PIPE AS
318C, 319C
318C, 319C
2023608
PIPE AS
318C, 319C
318C, 319C