4W4323 PIPE AS-AIR TRANSFER Caterpillar parts
3304, 930, D4E SR
Rating:
Alternative (cross code) number:
CA4W4323
4W-4323
4W4323
CA4W4323
4W-4323
4W4323
Weight: 20 pounds 9 kg.
GEN SET ENGINE, WHEEL LOADER,
This part in 2 request:
Show.
This information for suppliers only!
2020-06-16
2016-04-28
Compatible equipment models: 4W4323:
Information:
Illustration 1 g01453162
Typical schematic for the Cat Data LinkTest Step 1. Inspect the Electrical Connectors and the Wiring
Remove electrical power from the ECM.
Illustration 2 g01139425
ECM (1) J1/P1 connectors (2) J2/P2 connectors
Thoroughly inspect connector (1) and connector (2). Refer to Troubleshooting, "Electrical Connectors - Inspect".
Illustration 3 g01394774
P1 terminals that are associated with the Cat Data Link (P1-3) Cat Data Link − (P1-9) Cat Data Link +
Illustration 4 g01365685
Terminal locations at the service tool connector that are associated with the Cat Data Link (Terminal D) Cat Data Link + (Terminal E) Cat Data Link −
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the Cat Data Link.
Check the allen head screw on each ECM connector for the proper torque. Also, check the allen head screw on the customer connector for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values.Expected Result:All connectors, pins, and sockets are completely inserted and coupled. The harness and wiring are free of corrosion, of abrasion, and of pinch points.Results:
OK - The harness and the connectors appear to be OK. Proceed to Test Step 2.
Not OK - The connectors and/or the wiring are not OK.Repair: Repair the connectors and/or the wiring. Replace parts, if necessary. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled. Verify that the original problem is resolved.STOPTest Step 2. Check for a Short Circuit
Disconnect the P1 ECM connector and the P2 ECM connector.
Disconnect Cat ET from the service tool connector.
Disconnect any other control modules from the Cat Data Link. Refer to the electrical schematic in order to identify other control modules that are on the Cat Data Link.
Measure the resistance between the points that are listed in Table 1. Be sure to wiggle the wires in the harnesses as you make each resistance measurement.
Table 1
Resistance Measurements for the Cat Data Link    
Connector and Terminal    Terminal    
P1-9 (Cat Data Link +)     All of the other terminals on the P1 connector and the P2 connector    
Ground stud
P1-3 (Cat Data Link -)     All of the other terminals on the P1 connector and the P2 connector    
Ground stud Expected Result:Each check of the resistance indicates an open circuit.Results:
OK - Each check of the resistance indicates an open circuit. Proceed to Test Step 3.
Not OK - At least one check of the resistance does not indicate an open circuit. There is a short circuit in the harness or in a connector.Repair: Repair the connectors and/or the wiring. Replace parts, if necessary. Verify that the original problem is resolved.STOPTest Step 3. Check for an Open Circuit
Fabricate a jumper wire. Use the jumper wire in order to create a short circuit between terminals D (Cat Data Link +) and terminal E (Cat Data Link −) on the service tool connector.
Measure the resistance between P1-9 (Cat Data Link +) and P1-3 (Cat Data Link −).
Measure the resistance between the terminals at the connector for each
Caterpillar parts catalog:
Parts pipe Caterpillar catalog:
4W2927
PIPE
D379B
D379B
4W2626
PIPE
3512, D398B
3512, D398B
4W2628
PIPE
D398B, D399
D398B, D399
4W2627
PIPE
D399
D399
4W2629
PIPE
D398B, D399
D398B, D399
2Y8027
PIPE
140B, 3306, 930R
140B, 3306, 930R
2Y8031
PIPE
3304B, D4E, D6D, D6E
3304B, D4E, D6D, D6E
3P0089
PIPE AS-OUTLET
120G, 130G, 3304B, 950
120G, 130G, 3304B, 950
0346103
PIPE
G3306, G3412
G3306, G3412
1W2231
PIPE
D379B, D398B, D399
D379B, D398B, D399
1W5129
PIPE-OUTLET
3304, 930, D4E, D4E SR
3304, 930, D4E, D4E SR