Information:
Three-Phase Voltage Connections
The Wye Configuration for a 480 V generator is given in the following diagrams.The terminals must be connected securely. The terminals must also be insulated with a good quality electrical tape.Wye Configuration Diagrams
6 Lead Generators
Illustration 1 g00626053
Typical Wye Configuration12 Lead Generators
Illustration 2 g00637319
Typical Series Wye Configuration This is a typical high voltage connection.
Illustration 3 g00637320
Typical Parallel Wye ConfigurationThis is a typical high voltage connection.Single-Phase Current From a Three-Phase Generator
Three-phase current and single-phase current can be taken simultaneously from a generator that is connected for three-phase service. In the Wye Configuration, connect the load to the three-phase leads (any two of the three leads).Connect the load to any phase lead and neutral lead of the Wye Configuration. This will produce voltage at 58% of three-phase voltage.Refer to Operation Section, "Generator Operation" for allowable single-phase loading unbalance.Single-phase power that is taken from a three-phase source can be a problem. Ensure that the single-phase loading is equally distributed.Do not exceed the nameplate current rating for any one phase.Wye Configuration Diagrams
6 Lead Generators
Illustration 4 g00626132
Single-Phase Wiring Diagram with 6 Lead Wye Configuration12 Lead Generators
Illustration 5 g00637321
Single-Phase Wiring Diagram with 12 Lead Wye Configuration
The Wye Configuration for a 480 V generator is given in the following diagrams.The terminals must be connected securely. The terminals must also be insulated with a good quality electrical tape.Wye Configuration Diagrams
6 Lead Generators
Illustration 1 g00626053
Typical Wye Configuration12 Lead Generators
Illustration 2 g00637319
Typical Series Wye Configuration This is a typical high voltage connection.
Illustration 3 g00637320
Typical Parallel Wye ConfigurationThis is a typical high voltage connection.Single-Phase Current From a Three-Phase Generator
Three-phase current and single-phase current can be taken simultaneously from a generator that is connected for three-phase service. In the Wye Configuration, connect the load to the three-phase leads (any two of the three leads).Connect the load to any phase lead and neutral lead of the Wye Configuration. This will produce voltage at 58% of three-phase voltage.Refer to Operation Section, "Generator Operation" for allowable single-phase loading unbalance.Single-phase power that is taken from a three-phase source can be a problem. Ensure that the single-phase loading is equally distributed.Do not exceed the nameplate current rating for any one phase.Wye Configuration Diagrams
6 Lead Generators
Illustration 4 g00626132
Single-Phase Wiring Diagram with 6 Lead Wye Configuration12 Lead Generators
Illustration 5 g00637321
Single-Phase Wiring Diagram with 12 Lead Wye Configuration
Parts piston Caterpillar catalog:
3849629
PISTON GP-ROD&
Caterpillar
Caterpillar
3843962
PISTON
Caterpillar
Caterpillar
3814314
PISTON
Caterpillar
Caterpillar
3813521
PISTON
Caterpillar
Caterpillar
3813520
PISTON
Caterpillar
Caterpillar
3813519
PISTON
Caterpillar
Caterpillar
3941756
PISTON
Caterpillar
Caterpillar
3937928
PISTON
Caterpillar
Caterpillar
3926627
PISTON AS
Caterpillar
Caterpillar
3922006
PISTON
Caterpillar
Caterpillar
3882311
PISTON GP-ROD&
Caterpillar
Caterpillar
3855597
PISTON GP-ROD&
Caterpillar
Caterpillar