AVSPARE.COM
parts catalog

PLANETARY GP-TRANSMISSION 1148946 - Caterpillar


1148946 PLANETARY GP-TRANSMISSION Caterpillar parts 950G, 962G
Rating:
9
Alternative (cross code) number:
CA1148946
114-8946
1148946
Caterpillar 1148946 PLANETARY GP-TRANSMISSION

Buy PLANETARY GP-TRANSMISSION 1148946 Caterpillar genuine, new aftermarket tractor parts with delivery
WHEEL LOADER,

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$36.99

21 Oct 2025

US: Work House Sign
Estación de mascarillas Spanish Black Sign Arrow Right Aluminum Composite Sign 20 x 24 inches
Work House Signs Construcción de aluminio compuesto: ligero, fuerte y duradero. No se oxida ni se desgasta. Perfecto para uso prolongado en interiores o exteriores. || Disponible en 3 tamaños versátiles: elige el tamaño ideal para tu espacio, ya sea una pared pequeña o un área más grande. || Resistente al clima: soporta lluvia, sol y viento. Ideal para interiores o exteriores, sin perder color ni forma. || Montaje personalizable: sin agujeros pre-hechos, tú decides dónde perforar con cualquier broca estándar. Se adapta a cualquier superficie. || Hecho en EE.UU. con orgullo: diseñado e impreso por nuestro equipo local en Pennsylvania. Calidad artesanal de pequeño negocio.
Number on catalog scheme:
  For full view, you need register

Compatible equipment models: 1148946:

WHEEL LOADER  950G   962G   Caterpillar

Information:

IVR Voltage Adjustment
Voltage adjustments are categorized into two types, manual biasing and analog biasing. Manual voltage adjustment includes fine-tuning the generator output voltage via digital input, EMCP display, or SCADA ( Modbus). Analog voltage adjustment is performed via programmable analog inputs to the EMCP. Analog voltage adjustment provides a voltage control interface for external potentiometers or external control systems, such as switch gear.The generator maximum voltage bias percentage set point must be configured correctly to be greater than the expected bias range. If this set point is not correctly configured, the required voltage bias may not be possible to achieve. The generator maximum voltage bias percentage parameter is accessed with Cat ET Service Tool. The parameter is accessed through the configuration dialog under "Generator AC Monitor" or can be accessed with the EMCP display. Use the following to navigate to the EMCP sub menu.
Press the "MAIN MENU" button on the EMCP.
Use the arrow keys to select "CONFIGURE". Press the "OK" key.
Use the arrow keys to select "ALL SET POINTS". Press the "OK" key.
Use the arrow keys to select "GEN AC MONITOR". Press the "OK" key.Note: All manual voltage biasing is removed and reset to zero when the engine is stopped. Manual voltage bias levels are not carried over to the next startup after an engine shutdown.Digital Inputs
Remote voltage adjustment toggle switches may be used to fine-tune the generator output voltage. The process is accomplished by programming an EMCP digital input for raise voltage and lower voltage. Each activation of the digital input raises or lowers the voltage by 0.2% of rated. When the digital input is activated continuously, the voltage bias is raised or lowered by 0.2% of rated approximately every 400ms.Refer to Systems Operation, Test and Adjust, Troubleshooting, UENR1209, "Digital Input Programming" for further details on programming digital inputs on EMCP 4 controllers.Voltage / HZ Control (EMCP Display)
The EMCP display can be used to fine-tune the generator output voltage. Each press of the voltage raise or voltage lower key raises or lowers the voltage by 0.2% of rated voltage. When the voltage raise or voltage lower key is pressed and held continuously, the voltage bias is raised or lowered by 0.2% of rated approximately every 400ms.The "Voltage / Hz" screen can be found on the EMCP display. Use the following steps to navigate to the "Voltage / Hz" screen.
Press the "MAIN MENU" button on the EMCP.
Use the arrow keys to select "CONTROL". Press the "OK" key.
Use the arrow keys to select "VOLTAGE / Hz CONTROL". Press the "OK" key.
Illustration 13 g03488436
EMCP 4.1 and EMCP 4.2 Volts/Hz control screen
SCADA MODBUS (EMCP 4.2 ONLY)
EMCP 4.2 SCADA data link also provides a means for adjusting voltage remotely. EMCP 4.2 Modbus registers are defined for reading and controlling the target output voltage of the generator. Refer to Application and Installation Guide, LEBE0010, "EMCP 4 SCADA Data Links" for more details on EMCP 4.2 dedicated SCADA data links.Analog Inputs
Analog voltage adjustment is done via a programmable analog input to the EMCP configured for

Caterpillar parts catalog:

Caterpillar parts catalog
950G Wheel Loader 4BS00001-UP (MACHINE) POWERED BY 3126 Engine
950G Wheel Loader 2JS00001-UP (MACHINE) POWERED BY 3126 Engine
950G Wheel Loader 8JW00001-UP (MACHINE) POWERED BY 3126 Engine
950G Wheel Loader 3JW00001-UP (MACHINE) POWERED BY 3126 Engine
950G Wheel Loader 5FW00001-UP (MACHINE) POWERED BY 3126 Engine
950G WHEEL LOADER 5MW00001-00700 (MACHINE) POWERED BY 3126 ENGINE
962G WHEEL LOADER 6HW00001-00400 (MACHINE) POWERED BY 3126 ENGINE
950G WHEEL LOADER 6NS00001-00251 (MACHINE) POWERED BY 3126 ENGINE


Parts planetary Caterpillar catalog:

1862522 PLANETARY GP-TRANSMISSION
950G, 950G II, 950H, 962G II, 962H, IT62H
1862523 PLANETARY GP-TRANSMISSION
950G, 950G II, 962G, 962G II, IT62G, IT62G II
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.