6V5921 PLANETARY TRANSMISSION Caterpillar parts
D8L  
 
 
Rating:
 Alternative (cross code) number:
CA6V5921
6V-5921
6V5921
 
CA6V5921
6V-5921
6V5921
 
  Weight: 1 pounds 0 kg. 
  TRACK-TYPE TRACTOR,
Compatible equipment models: 6V5921:
Information:
Illustration 1 g01449608
Circuit of the Axle Oil CoolerThis diagnostic code is associated with the rear axle oil cooler bypass solenoid. The FMI 03 means that the ECM has determined that the voltage of the solenoid circuit is above normal. The possible causes of the diagnostic code are listed:
The solenoid has failed.
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1584 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J2-2 (wire J887-PU) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-2 (J887-PU) and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 1584 FMI 03 is active.Expected Result:The CID 1584 FMI 03 is active.Results:
YES - The CID 1584 FMI 03 is active. The problem has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NO - The CID 1584 FMI 03 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
Caterpillar parts catalog:
Parts planetary Caterpillar catalog:
 9P6236
PLANETARY GP
 
589, D8L
  
589, D8L
 6V4529
PLANETARY TRANSMISSION
 
D8L, D9L
 
D8L, D9L
 6V1569
PLANETARY TRANSMISSION
 
824C, 825C, 826C, 834B
 
824C, 825C, 826C, 834B
 436271230
PLANETARY CAGE
 
PR-275
 
PR-275
 43660951
PLANETARY CAGE
 
PR-275
 
PR-275
 413513
PLANETARY GEARBOX
 
PR-450
 
  
PR-450
 8T7045
PLANETARY
 
14G, 160G, 16G
 
14G, 160G, 16G
 6V9213
PLANETARY
 
120G, 12G, 130G
 
 
120G, 12G, 130G
 8C8462
PLANETARY
 
D10N
 
D10N
 8C0584
PLANETARY
 
D9N
 
D9N
 3E7489
PLANETARY
 
D9N
 
D9N