1013354 PLATE Caterpillar parts
Rating:
Alternative (cross code) number:
CA1013354
101-3354
1013354
CA1013354
101-3354
1013354
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
1013354 - OEM Upgraded Furnace Control Gas Valve Replaces Tempstar
ClimaTek ▶ This is a brand new OEM upgraded Furnace Control Gas Valve || ▶ This OEM Part Directly Replaces Part # 1013354 || ▶ Top Quality OEM Replacement Part, Built to Last! || ▶ Works with Tempstar and more!
ClimaTek ▶ This is a brand new OEM upgraded Furnace Control Gas Valve || ▶ This OEM Part Directly Replaces Part # 1013354 || ▶ Top Quality OEM Replacement Part, Built to Last! || ▶ Works with Tempstar and more!
1013354 - OEM Upgraded Furnace Control Gas Valve Replaces Heil
ClimaTek ▶ This is a brand new OEM upgraded Furnace Control Gas Valve || ▶ This OEM Part Directly Replaces Part # 1013354 || ▶ Top Quality OEM Replacement Part, Built to Last! || ▶ Works with Heil and more!
ClimaTek ▶ This is a brand new OEM upgraded Furnace Control Gas Valve || ▶ This OEM Part Directly Replaces Part # 1013354 || ▶ Top Quality OEM Replacement Part, Built to Last! || ▶ Works with Heil and more!
1013354 - OEM Upgraded Furnace Control Gas Valve Replaces ICP
ClimaTek ▶ This is a brand new OEM upgraded Furnace Control Gas Valve || ▶ This OEM Part Directly Replaces Part # 1013354 || ▶ Top Quality OEM Replacement Part, Built to Last! || ▶ Works with ICP and more!
ClimaTek ▶ This is a brand new OEM upgraded Furnace Control Gas Valve || ▶ This OEM Part Directly Replaces Part # 1013354 || ▶ Top Quality OEM Replacement Part, Built to Last! || ▶ Works with ICP and more!
Information:
Illustration 1 g02035394
Schematic of the "Attachment Stem #2 Retract Pressure" SolenoidThis diagnostic code is associated with the "Attachment Stem #2 Retract Pressure" Solenoid. The FMI 03 diagnostic code means that the Machine ECM has determined that the voltage is above normal.The possible causes of the diagnostic code are listed below:
The solenoid has failed.
The energizer circuit of the solenoid for the modulating valve is shorted to the +battery circuit.
The Machine ECM has failed. A failure of the ECM is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1597 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.Test Step 1. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO THE +BATTERY CIRCUIT
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the Machine ECM.
At the machine harness connector for the ECM, measure the resistance from contact J2-3 (wire K861-GN) to all contacts that are used in the machine harness connectors for the Machine ECM.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-3 (K861-GN) and the circuit that has a low resistance measurement.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 1597 FMI 03 diagnostic code is active.Expected Result:The CID 1597 FMI 03 diagnostic code is active.Results:
YES - The CID 1597 FMI 03 diagnostic code is active. The problem has not been corrected. The ECM may have failed.Repair: A failure of the ECM is unlikely. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the Machine ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NO - The CID 1597 FMI 03 diagnostic code is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors. Resume normal machine operation.STOP
Parts plate Caterpillar catalog:
1013353
PLATE
Caterpillar
Caterpillar
1013352
PLATE
Caterpillar
Caterpillar
1013337
PLATE
Caterpillar
Caterpillar
1012577
PLATE
Caterpillar
Caterpillar
1012563
PLATE
Caterpillar
Caterpillar
1012562
PLATE-ROPS/
Caterpillar
Caterpillar
1013355
PLATE
Caterpillar
Caterpillar
1013356
PLATE
Caterpillar
Caterpillar
1013357
PLATE
Caterpillar
Caterpillar
1013358
PLATE
Caterpillar
Caterpillar
1013359
PLATE
Caterpillar
Caterpillar
1013360
PLATE
Caterpillar
Caterpillar