1101627 PLATE Caterpillar parts
24H, 3408E, 3412E, 5110B, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 844, 988B, 988F II, 990, 990 II, 992C, AD40, AD45, AE...
Rating:
Alternative (cross code) number:
CA1101627
110-1627
1101627
CA1101627
110-1627
1101627
Weight: 1 pounds 0 kg.
COLD PLANER, WHEEL TRACTOR,
Compatible equipment models: 1101627:
Information:
AC Output Current calibration is done with a load on the system. Only maximum current on each output bus is calibrated.
Personal injury or death can result from high voltage.When power generation equipment must be in operation to make tests and/or adjustments, high voltage and current are present.Improper test equipment can fail and present a high voltage shock hazard to its user.Use electrical safety gloves when you are working in the cabinets.Make sure the testing equipment is designed for and correctly operated for high voltage and current tests being made.
Calibration Error Limits
Table 1
Parameter     Nominal Target     Percent Deviation    
Output Current, Pre Transformer O/P Current full scale     1400 A     1.0    Note: The system should be in Bypass mode.
Connect a PC to the UPS.Refer to Systems Operation, Testing and Adjusting, RENR7654, "Personal Computer to UPS Connection".
Place system in Bypass mode.Refer to Systems Operation, Testing and Adjusting, RENR7654, "Transfer to Bypass Mode".Note: Before proceeding, if this is a Paralleled MMU system, calibrate the MMU Currents from the Parallel Control cabinet (PCC).
Select "AC Output Currents".Note: 4-Wire menu options only appear in 4-Wire systems.
Select "Use Defaults".
Place probe clamp on the K5 bus bar for Phase A.
Illustration 1 g01307126
Current Probe ClampNote: Clamp should be rated at a 3000 amp maximum, 10 Hz to 100 kHz. The clamp should be set to 0.1 millivolts per amp.
Illustration 2 g01298917
(1) Ground (2) Phase C Output Bus Bar (3) Phase B Output Bus Bar (4) Phase A Output Bus Bar (5) Output Breaker K5 (Optional) (6) Input Breaker K1 (7) Phase A Input Bus Bar (8) Phase B Input Bus Bar (9) Phase C Input Bus Bar (10) Left Component Panel
Illustration 3 g01307130
Probe Clamp Range and Output
Take reading from the K5 bus bar for Phase A.
Enter reading into "Calibration Point".
Select "OK".
Move the clamp to the K5 bus bar for Phase B.
Take a reading.
Enter the value for Phase B that is shown on multimeter in the "Enter Calibration Point" window.
Illustration 4 g01307177
Output Current Entered for Phase B
Select "OK".
Move clamp to the K5 bus bar for Phase C.
Take a reading.
Enter the value for Phase C that is shown on multimeter in "Enter Calibration Point" window.
Illustration 5 g01307178
Output Current Entered for Phase C
Select "OK".
Select "View Status".
Illustration 6 g01307179
Phase A, Phase B, and Phase C Output Current Calibration Status
Select "Save". The AC Output Current calibration is complete.
Personal injury or death can result from high voltage.When power generation equipment must be in operation to make tests and/or adjustments, high voltage and current are present.Improper test equipment can fail and present a high voltage shock hazard to its user.Use electrical safety gloves when you are working in the cabinets.Make sure the testing equipment is designed for and correctly operated for high voltage and current tests being made.
Calibration Error Limits
Table 1
Parameter     Nominal Target     Percent Deviation    
Output Current, Pre Transformer O/P Current full scale     1400 A     1.0    Note: The system should be in Bypass mode.
Connect a PC to the UPS.Refer to Systems Operation, Testing and Adjusting, RENR7654, "Personal Computer to UPS Connection".
Place system in Bypass mode.Refer to Systems Operation, Testing and Adjusting, RENR7654, "Transfer to Bypass Mode".Note: Before proceeding, if this is a Paralleled MMU system, calibrate the MMU Currents from the Parallel Control cabinet (PCC).
Select "AC Output Currents".Note: 4-Wire menu options only appear in 4-Wire systems.
Select "Use Defaults".
Place probe clamp on the K5 bus bar for Phase A.
Illustration 1 g01307126
Current Probe ClampNote: Clamp should be rated at a 3000 amp maximum, 10 Hz to 100 kHz. The clamp should be set to 0.1 millivolts per amp.
Illustration 2 g01298917
(1) Ground (2) Phase C Output Bus Bar (3) Phase B Output Bus Bar (4) Phase A Output Bus Bar (5) Output Breaker K5 (Optional) (6) Input Breaker K1 (7) Phase A Input Bus Bar (8) Phase B Input Bus Bar (9) Phase C Input Bus Bar (10) Left Component Panel
Illustration 3 g01307130
Probe Clamp Range and Output
Take reading from the K5 bus bar for Phase A.
Enter reading into "Calibration Point".
Select "OK".
Move the clamp to the K5 bus bar for Phase B.
Take a reading.
Enter the value for Phase B that is shown on multimeter in the "Enter Calibration Point" window.
Illustration 4 g01307177
Output Current Entered for Phase B
Select "OK".
Move clamp to the K5 bus bar for Phase C.
Take a reading.
Enter the value for Phase C that is shown on multimeter in "Enter Calibration Point" window.
Illustration 5 g01307178
Output Current Entered for Phase C
Select "OK".
Select "View Status".
Illustration 6 g01307179
Phase A, Phase B, and Phase C Output Current Calibration Status
Select "Save". The AC Output Current calibration is complete.
Cat SIS web machinery list:
Parts plate Caterpillar catalog:
6E4233
PLATE-VALVE
14M, 16M, 24H, 24M, 789D, 793, 793B, D9R
14M, 16M, 24H, 24M, 789D, 793, 793B, D9R
3P8160
PLATE-CLUTCH
769C, 772B, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, AD55B, AD60
769C, 772B, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, AD55B, AD60
1233698
PLATE
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
1233699
PLATE
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
7X5513
PLATE
AP-1000, AP-1000B, AP-1050, AP-1055B, AP-1200, AP-800, AP-800C, AP-900B, BG-225B, BG-225C, BG-2455C, BG-245C, CP-433B, CP-433C, CP-433E, CP-44, CP-563, CS-323C, CS-423E, CS-431B, CS-431C, CS-433C, CS-...
AP-1000, AP-1000B, AP-1050, AP-1055B, AP-1200, AP-800, AP-800C, AP-900B, BG-225B, BG-225C, BG-2455C, BG-245C, CP-433B, CP-433C, CP-433E, CP-44, CP-563, CS-323C, CS-423E, CS-431B, CS-431C, CS-433C, CS-...
9P7053
PLATE-THRUST
D8L, D9L, D9N, D9R, D9T
D8L, D9L, D9N, D9R, D9T
7G9708
PLATE-THRUST
D10N, D8L, D9L, D9N, D9R, D9T
D10N, D8L, D9L, D9N, D9R, D9T
1105435
PLATE AS
D10R, D10T, D10T2
D10R, D10T, D10T2
8E2902
PLATE-THRUST
D10N, D10R, D10T, D10T2
D10N, D10R, D10T, D10T2
1109282
PLATE-RETAINER
D10R, D10T, D10T2
D10R, D10T, D10T2
1090063
PLATE-BRAKE
D10R, D10T, D10T2
D10R, D10T, D10T2
7G5972
PLATE
D10N, D8L, D9L
D10N, D8L, D9L
1412754
PLATE-IDENTIFICATION
3516, 3516B
3516, 3516B
1837615
PLATE
3516B
3516B
7W2285
PLATE-EXTENSION
3508, 3508B, 3512, 3512B, 3516, 3516B, G3512, G3516
3508, 3508B, 3512, 3512B, 3516, 3516B, G3512, G3516
7W1986
PLATE AS
3508, 3508B, 3512, 3512B, 3516, 3516B, G3512, G3516
3508, 3508B, 3512, 3512B, 3516, 3516B, G3512, G3516
7W2442
PLATE
3512, 3512B, 3516, 3516B
3512, 3512B, 3516, 3516B
7C7147
PLATE AS
3512, 3512B, 3516, 3516B
3512, 3512B, 3516, 3516B
1246640
PLATE
24H, 3408E, 3412E, 5110B, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 844, 988B, 988F II, 990, 990 II, 992C, AD40, AE40, C3...
24H, 3408E, 3412E, 5110B, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 844, 988B, 988F II, 990, 990 II, 992C, AD40, AE40, C3...
1502392
PLATE-THRUST
24H, 3408E, 3412E, 5110B, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 844, 988B, 988F II, 990, 990 II, 992C, AD40, AE40, C3...
24H, 3408E, 3412E, 5110B, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 844, 988B, 988F II, 990, 990 II, 992C, AD40, AE40, C3...
1539121
PLATE
3412E, C30, C32
3412E, C30, C32
1443287
PLATE
3412E, 966H, C30, C32
3412E, 966H, C30, C32
3759974
PLATE
3412, 3412C, 3412D, 3412E
3412, 3412C, 3412D, 3412E
1016713
PLATE-RETAINING
24H, 3408E, 3412E, 5110B, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 844, 988B, 988F II, 990, 990 II, 992C, AD40, AD45, AE...
24H, 3408E, 3412E, 5110B, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 844, 988B, 988F II, 990, 990 II, 992C, AD40, AD45, AE...