Illustration 1 g00787031
Schematic of the pressure switch (low park brake)Test Step 1. CHECK THE NORMALLY CLOSED CIRCUIT FOR PROPER OPERATION.
Turn the key start switch to the ON position. Do NOT start the engine.
Disconnect the pressure switch from the machine harness.
At the machine harness connectors, measure the voltage from contact 1 (wire F795-YL) to contact 2 (wire G939-PK). Expected Result:Voltage should be between 4.0 VDC and 5.25 VDC.Results:
OK - The voltage is with an acceptable range. Proceed to test step 2.
NOT OK - The voltage is not with an acceptable range. Repair: The machine harness has failed. The return circuit (wire J764-BR) is open or the normally closed circuit (wire C491-PU) is open or shorted. Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK THE SWITCH FOR NORMAL OPERATION.
Remove the pressure switch and replace the switch with a gauge that is capable of at least 3000 kPa (435 psi).
Start the engine and run the engine at high idle.
Engage the parking brake. Measure the pressure.Expected Result:When the parking brake is engaged, the pressure should be greater than 400 kPa (58 psi).Results:
OK - The pressure is correct.Repair: The switch has failed. Replace the pressure switch for the hydraulic system pilot. Verify that the new switch corrects the problem.STOP
NOT OK - The pressure is not correct.Repair: There is a problem with the hydraulic system. Refer to Systems Operation and Testing and Adjusting, RENR5540, "Hydraulic System".STOPTest Step 3. CHECK IF THE PROBLEM REMAINS.
Clean the contacts of the harness connectors.
Reconnect all harness connections.
Perform the test that is outlined in Testing and Adjusting, "Pressure Switch (Hydraulic System Pilot) - Check". This verifies the operation of the switch.Expected Result:The switch operates correctly.Results:
OK - The switch operates correctly. The problem does not exist at this time. The initial problem was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
NOT OK - The switch does not operate correctly.Repair: Replace the switch.STOP
Caterpillar parts catalog:
Parts plate Caterpillar catalog:
2J2257
PLATE ASSEM.
8A, 9A
8A, 9A
4J7022
PLATE ASSEM.
8A, 8U, 9A, D9G
8A, 8U, 9A, D9G
5J4261
PLATE
8A, 9A
8A, 9A
4J4468
PLATE ASSEM.
10S, 621H, 621K, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 637D, 637E, 637G, 657E, 657G, 824S, 8A, 8S, 9A, D10, D9G, D9H, D9L
10S, 621H, 621K, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 637D, 637E, 637G, 657E, 657G, 824S, 8A, 8S, 9A, D10, D9G, D9H, D9L
4J8064
PLATE ASSEM.
8A, 8S, D8H, D9H
8A, 8S, D8H, D9H
8J7978
PLATE
814B, 814F, 814F II, 814S, 8A, 8S, 8U, 977K, 977L, 9A, 9S
814B, 814F, 814F II, 814S, 8A, 8S, 8U, 977K, 977L, 9A, 9S
9J1659
PLATE (wear)
8A, 8S
8A, 8S
9J7539
PLATE (R.H.)
8A, 8S
8A, 8S
9J7540
PLATE (L.H.)
8A, 8S
8A, 8S
8G3870
PLATE
D8N
D8N
8Y7077
PLATE-RH
D5C
D5C
8Y7076
PLATE-LH
D5C
D5C
8Y3850
PLATE
943, 953
943, 953
8Y5251
PLATE AS
943
943
8Y6720
PLATE AS
931C II, D3C II
931C II, D3C II
8Y6719
PLATE
931C II, D3C II
931C II, D3C II
1J6198
PLATE ASSEM.
4S, 955C, 955H
4S, 955C, 955H
5Y2196
PLATE AS.GUARD
D4E, D4E SR
D4E, D4E SR