Use this procedure in order to troubleshoot the air inlet heater or use this procedure if any one of the diagnostic codes in Table 1 is active or logged.
Table 1
Diagnostic Codes Table
Code and Description Conditions which Generate this Code System Response
617-5 Inlet Air Heater Relay current below normal The Electronic Control Module (ECM) detects a current flow that is below normal during an attempt to energize the air inlet heater relay. The code is latched. The code is logged.
The air inlet heater will be disabled if an open has occurred in the wiring in the circuit. The air inlet heater will be energized continuously if a short to the +Battery has occurred in the wiring in the circuit.
617-6 Inlet Air Heater Relay current above normal The ECM detects excessive current during an attempt to energize the air inlet heater relay. The code is latched. The code is logged.
The air inlet heater will be disabled.
The engine may experience hard starting and/or the engine may emit excessive white smoke. The air inlet heater improves the engine's ability to start when the engine is cold. A reduction of white smoke is also a benefit of the air inlet heater.The ECM activates the air inlet heater via the air inlet heater relay. The air inlet heater is activated according to the following cycles:
Power up cycle
Preheat cycle
Crank cycle
Running cycle
Postheat cyclePower Up Cycle - The ECM activates the air inlet heater for two seconds after the ECM is first powered up regardless of temperature or engine speed.Preheat Cycle - If the coolant temperature is less than 49 °C (120 °F), the ECM activates the air inlet heater for 30 seconds. If the operator attempts to start the engine before the end of the preheat cycle, the ECM will begin using the strategy for the crank cycle.Crank Cycle - When the engine is cranking and the coolant temperature is less than 49 °C (120 °F), the air inlet heater will remain on while the engine is cranking. If the engine fails to start, the ECM will revert to the preheat cycle.Running Cycle - The air inlet heater will remain on after the engine has started. If the coolant temperature does not reach 49 °C (120 °F) within five minutes, the ECM will use the postheat cycle.Postheat Cycle - The air inlet heater will cycle on and off if the coolant temperature is still less than 49 °C (120 °F). The heater will turn on for 30 seconds. Then, the heater will turn off for 10 seconds. This cycle continues for 15 minutes. The cycle ends if the coolant temperature exceeds 49 °C (120 °F).
Illustration 1 g01381734
Schematic for the air inlet heater
The connection of any electrical equipment and the disconnection of any electrical equipment may cause an explosion hazard which may result in injury or death. Do not connect any electrical equipment or disconnect any electrical equipment in an explosive atmosphere.
Illustration 2 g01338263
Typical left side engine view
(1) Air inlet heater relay
(2) Connector for the air inlet heater relay
(3)
Table 1
Diagnostic Codes Table
Code and Description Conditions which Generate this Code System Response
617-5 Inlet Air Heater Relay current below normal The Electronic Control Module (ECM) detects a current flow that is below normal during an attempt to energize the air inlet heater relay. The code is latched. The code is logged.
The air inlet heater will be disabled if an open has occurred in the wiring in the circuit. The air inlet heater will be energized continuously if a short to the +Battery has occurred in the wiring in the circuit.
617-6 Inlet Air Heater Relay current above normal The ECM detects excessive current during an attempt to energize the air inlet heater relay. The code is latched. The code is logged.
The air inlet heater will be disabled.
The engine may experience hard starting and/or the engine may emit excessive white smoke. The air inlet heater improves the engine's ability to start when the engine is cold. A reduction of white smoke is also a benefit of the air inlet heater.The ECM activates the air inlet heater via the air inlet heater relay. The air inlet heater is activated according to the following cycles:
Power up cycle
Preheat cycle
Crank cycle
Running cycle
Postheat cyclePower Up Cycle - The ECM activates the air inlet heater for two seconds after the ECM is first powered up regardless of temperature or engine speed.Preheat Cycle - If the coolant temperature is less than 49 °C (120 °F), the ECM activates the air inlet heater for 30 seconds. If the operator attempts to start the engine before the end of the preheat cycle, the ECM will begin using the strategy for the crank cycle.Crank Cycle - When the engine is cranking and the coolant temperature is less than 49 °C (120 °F), the air inlet heater will remain on while the engine is cranking. If the engine fails to start, the ECM will revert to the preheat cycle.Running Cycle - The air inlet heater will remain on after the engine has started. If the coolant temperature does not reach 49 °C (120 °F) within five minutes, the ECM will use the postheat cycle.Postheat Cycle - The air inlet heater will cycle on and off if the coolant temperature is still less than 49 °C (120 °F). The heater will turn on for 30 seconds. Then, the heater will turn off for 10 seconds. This cycle continues for 15 minutes. The cycle ends if the coolant temperature exceeds 49 °C (120 °F).
Illustration 1 g01381734
Schematic for the air inlet heater
The connection of any electrical equipment and the disconnection of any electrical equipment may cause an explosion hazard which may result in injury or death. Do not connect any electrical equipment or disconnect any electrical equipment in an explosive atmosphere.
Illustration 2 g01338263
Typical left side engine view
(1) Air inlet heater relay
(2) Connector for the air inlet heater relay
(3)
Caterpillar parts catalog:
Parts plate Caterpillar catalog:
2D4202
PLATE
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12E, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12E, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
8H7577
PLATE-LOCKING
561D, 571G, 578, 583R, 587R, 589, 977K, 983B, D10, D4E, D4E SR, D5, D5B, D5E, D6D, D6E SR, D7G
561D, 571G, 578, 583R, 587R, 589, 977K, 983B, D10, D4E, D4E SR, D5, D5B, D5E, D6D, D6E SR, D7G
4N0342
PLATE-CAMSHAFT THRUST
16G, 16H NA, 245, 245D, 24H, 3406, 3406B, 3406C, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 375, 375 L, 5080, 5110B, 578, 583R, 587R, 589, 621E, 621F, 623E, 623F, 627B, 627E, 627F, 631D, 63...
16G, 16H NA, 245, 245D, 24H, 3406, 3406B, 3406C, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 375, 375 L, 5080, 5110B, 578, 583R, 587R, 589, 621E, 621F, 623E, 623F, 627B, 627E, 627F, 631D, 63...
7E9262
PLATE-THRUST
245B, 24H, 3406B, 3406E, 3408, 3412, 3412C, 3412E, 375, 375 L, 5080, 5110B, 583R, 589, 621E, 631G, 637G, 651E, 657E, 769C, 769D, 771C, 771D, 773B, 773E, 775B, 824C, 826C, 980C, 980F, 980G, 980H, 988F,...
245B, 24H, 3406B, 3406E, 3408, 3412, 3412C, 3412E, 375, 375 L, 5080, 5110B, 583R, 589, 621E, 631G, 637G, 651E, 657E, 769C, 769D, 771C, 771D, 773B, 773E, 775B, 824C, 826C, 980C, 980F, 980G, 980H, 988F,...
7N1282
PLATE AS-BRUSH
1673C, 215, 225, 3304, 3306, 3306B, 518, 920, 943, 950B, 963, D250B, D25C, D300B, D30C, D350C, D35C, D4D, D4E, D5B, G936, IT28, IT28B
1673C, 215, 225, 3304, 3306, 3306B, 518, 920, 943, 950B, 963, D250B, D25C, D300B, D30C, D350C, D35C, D4D, D4E, D5B, G936, IT28, IT28B
1S5242
PLATE (warning)
225, 235, 561C, 561D, 571G, 572G, 583K, 594, 594H, 931, 941, 951B, 955H, 955K, 955L, 977H, 977K, 977L, 983, 983B, D3, D4D, D4E, D5, D5B, D6C, D6D, D6D SR, D6E, D6E SR, D6F SR, D6G, D6G SR, D6G2 LGP, D...
225, 235, 561C, 561D, 571G, 572G, 583K, 594, 594H, 931, 941, 951B, 955H, 955K, 955L, 977H, 977K, 977L, 983, 983B, D3, D4D, D4E, D5, D5B, D6C, D6D, D6D SR, D6E, D6E SR, D6F SR, D6G, D6G SR, D6G2 LGP, D...
6T1711
PLATE
D6D, D6E, D6E SR, D6G, D6G SR, D6G2 XL
D6D, D6E, D6E SR, D6G, D6G SR, D6G2 XL
7M2527
PLATE
D6C, D6D, D6E, D6E SR, D6G, D6G SR
D6C, D6D, D6E, D6E SR, D6G, D6G SR
1M4179
PLATE
594, 594H, D8H, D8K, D9G, D9H
594, 594H, D8H, D8K, D9G, D9H
6P6653
PLATE
571G, 572G, D7F, D7G, D7G2
571G, 572G, D7F, D7G, D7G2
9S8789
PLATE
572G, 631C, 631E, 631G, 633C, 633E II, 637E, 637G, 657E, 657G, D7F, D7G, D7G2
572G, 631C, 631E, 631G, 633C, 633E II, 637E, 637G, 657E, 657G, D7F, D7G, D7G2
1105435
PLATE AS
D10R, D10T, D10T2
D10R, D10T, D10T2
1P6176
PLATE
55, 57, 58, 594H, D10N, D10R, D5B, D6D, D7G, D8L, D9L, D9N
55, 57, 58, 594H, D10N, D10R, D5B, D6D, D7G, D8L, D9L, D9N
1P9256
PLATE
528, 54, 55, D5B, D6D
528, 54, 55, D5B, D6D
1P7544
PLATE
528, 54, 55, D5B, D6D
528, 54, 55, D5B, D6D
9K1656
PLATE ASSEM.
951B
951B
3K7505
PLATE
977H
977H
2P8980
PLATE
55
55
2P7964
PLATE
55
55
3P2421
PLATE ASSEM.
58, D8H
58, D8H
8J4164
PLATE
D9H
D9H
2K5644
PLATE
769, 950, 955C, 966C, 988, D7F
769, 950, 955C, 966C, 988, D7F
8J4924
PLATE
8U
8U