Illustration 8 g03318731
Use vibratory frequency switch (10) in order to set the vibratory system in the low frequency/high amplitude mode on both drums. Note: Two things indicate when the vibratory system is in the low frequency/high amplitude mode. "Vibratory Frequency Mode Low" will appear on the display. Second, one LED next to vibratory frequency switch (10) will be illuminated.
Illustration 9 g03318732
Use front drum select switch (11) in order to select the front drum.Note: Two things indicate when the machine is in both drums mode. First, "Vibe Drum Select Front" will appear on the display. Second, the center LED next to "front drum" select switch (11) will be illuminated.
Illustration 10 g03319012
Depress auto vibratory decrease switch (12) to select the MANUAL mode.Note: Two things indicate when the vibratory system is in the manual mode. First, "Vibe Turn On Speed % Manual" will appear on the display. Second, none of the LEDs next to auto vibratory decrease switch (12) will be illuminated.
Launch the Plus+1TM program on the computer in order to enable the vibe test mode.Note: First time users need to perform the tasks in the Communication and Connections Wizard. This wizard allows the Windows® operating system to recognize the USB device. Follow the on screen instructions.
Illustration 11 g03319013
Click on "Status" icon (13) .
Check "Active Codes" (14). Clear any open "Active Codes".
Illustration 12 g03319017
Click on "Hydraulics" (15) .
Click on "Vibe Test Mode" (16) .
Illustration 13 g03319018
Click on "Enable" icon (17) in order to enable the "Normal Vibe Test Mode".
When "Normal Vibe Test Mode" is in "Enabled" mode, the Plus+1 program is launched.
Illustration 14 g03319020
Press vibratory control switch (18) on the propel lever. The vibratory control switch must be held in the ON position for at least 2 seconds for the vibratory system to actuate.
Watch pressure on Tool (A) for an initial abrupt increase. Record the highest pressure as the intercircuit relief setting. The intercircuit relief setting should be 25000 2000 kPa (3630 290 psi).
Use vibratory control switch (18) to stop the vibratory system.
Use throttle control switch (3) in order to operate the engine in ECO mode or in low idle.Note: Two things indicate when the engine is in ECO mode. First, "ECO" will appear on the display. Second, the second LED next to throttle control switch (3) will be illuminated. Two things indicate when the engine is at low idle. First, "Low Idle" will appear on the display. Second, the first LED next to the throttle control switch will be illuminated.
Move parking brake switch (2) to the ON position.
Move
Caterpillar parts catalog:
Parts plate Caterpillar catalog:
5K8751
PLATE
988
988
9M1794
PLATE ASSEM.
824, 988
824, 988
2Q0412
PLATE
992C
992C
2Q3786
PLATE
992D
992D
5K6628
PLATE
980
980
5S7913
PLATE
980
980
5S1924
PLATE
988
988
5S4785
PLATE
988
988