2501084 PLATE GP-SCREED Caterpillar parts AS2301 PLATE
Rating:
Alternative (cross code) number:
CA2501084
250-1084
2501084
CA2501084
250-1084
2501084

Buy PLATE GP-SCREED 2501084 Caterpillar genuine, new aftermarket tractor parts with delivery
ASPHALT SCREED,
Compatible equipment models: 2501084:
ASPHALT SCREED AS2301
Caterpillar
Information:
This diagnostic code is designed to indicate a short circuit (high current) in either the solenoid or the wiring for the electronic unit injector for No. 5 cylinder.The Electronic Control Module (ECM) detects the following conditions:
A high current condition (short circuit) for each of five consecutive attempts to operate
Battery voltage above 9 Volts DC for 2 secondsSystem Response:A warning will appear on the display on the control panel. The ECM will log the diagnostic code.Possible Performance Effect:The engine will have low power and/or rough running.Troubleshooting:When an injector cutout test is performed, a faulty electronic unit injector will indicate a low reading in comparison with the other electronic unit injectors.An electrical fault can prevent the electronic unit injector from operating. A short circuit in the wiring or the ECM that is unique to one electronic unit injector will prevent that individual electronic unit injector from operating. A short circuit in common wiring within the ECM can prevent the three electronic unit injectors that share that common wiring from operating.The ECM will continue to attempt to operate the electronic unit injector after the diagnostic code has been logged but a short circuit will prevent the operation of the electronic unit injector.Test Step 1. Perform the following diagnostic procedure: "Injector Solenoid Circuit - Test"Results:
OK - STOP
A high current condition (short circuit) for each of five consecutive attempts to operate
Battery voltage above 9 Volts DC for 2 secondsSystem Response:A warning will appear on the display on the control panel. The ECM will log the diagnostic code.Possible Performance Effect:The engine will have low power and/or rough running.Troubleshooting:When an injector cutout test is performed, a faulty electronic unit injector will indicate a low reading in comparison with the other electronic unit injectors.An electrical fault can prevent the electronic unit injector from operating. A short circuit in the wiring or the ECM that is unique to one electronic unit injector will prevent that individual electronic unit injector from operating. A short circuit in common wiring within the ECM can prevent the three electronic unit injectors that share that common wiring from operating.The ECM will continue to attempt to operate the electronic unit injector after the diagnostic code has been logged but a short circuit will prevent the operation of the electronic unit injector.Test Step 1. Perform the following diagnostic procedure: "Injector Solenoid Circuit - Test"Results:
OK - STOP
Caterpillar SIS machinery equipment:
Caterpillar SIS
- AS2301 Screed AWC00001-UP » 250-1084 PLATE GP-SCREED
- AS2301 Screed AWC00001-UP » 250-1084 PLATE GP-SCREED
Caterpillar parts catalog:
Parts plate Caterpillar catalog:
3109816
PLATE GP-SCREED
AP-600D, AP-655D, AP555E, AS4251C
AP-600D, AP-655D, AP555E, AS4251C
3265686
PLATE & FILM GP
242B3, 252B3
242B3, 252B3
3100700
PLATE & FILM GP
120M 2
120M 2
1140278
PLATE & FILM GP
75C, 75D
75C, 75D
2496982
PLATE GP-SCREED
10-20B
10-20B
2829844
PLATE & FILM GP
VRG-20/2, VRG-40/2
VRG-20/2, VRG-40/2
1400129
PLATE & FILM GP
773D, 775D
773D, 775D
3797354
PLATE & FILM GP
311D LRR
311D LRR