Information:
Illustration 1 g01242198
Tong Close Pressure Sensor connectionsThis diagnostic code is associated with the tong close pressure sensor. The FMI 03 means that the ECM has determined that the voltage of the sensor signal circuit is above normal. The pressure sensor sends a variable voltage input to the ECM that will indicate the system hydraulic pressure as the tong closes.The possible causes of this diagnostic code are listed below:
The signal circuit for the sensor is shorted to ground.
The sensor has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID