3035686 PLATE AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA3035686
303-5686
3035686
CA3035686
303-5686
3035686
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Component Terminal, Integrated BY255 diode; PTME 6-DIO BY255/LR; 3035686
Wczlekp Terminal Blocks; || Component terminal, integrated BY255 diode; PTME 6-DIO BY255/LR; 3035686
Wczlekp Terminal Blocks; || Component terminal, integrated BY255 diode; PTME 6-DIO BY255/LR; 3035686
DUCRES Fuel Injection Pump Compatible With Cummins Engine K19 KTA19 QSK19 NT855 3035686
DUCRES Part Name: 3035686 Fuel Injection Pump || Part Number: 3035686 || Compatible with Cummins Engine K19 KTA19 QSK19 NT855 || Package includes: 1 PC Fuel Injection Pump || Please be sure to compare carefully with photos and check part number before buying item.If you can't confirm your engine model or part number. Please leave us a message, we will help you confirm that the purchased product is what you need
DUCRES Part Name: 3035686 Fuel Injection Pump || Part Number: 3035686 || Compatible with Cummins Engine K19 KTA19 QSK19 NT855 || Package includes: 1 PC Fuel Injection Pump || Please be sure to compare carefully with photos and check part number before buying item.If you can't confirm your engine model or part number. Please leave us a message, we will help you confirm that the purchased product is what you need
Information:
Illustration 1 g01079591
The ECM detects and diagnoses most failures of the reduced rimpull function. However the ECM does not detect a failure with the reduced rimpull ON/OFF switch or the reduced rimpull selection switch.If the reduced rimpull function does not operate correctly, check for related diagnostic codes. Correct any related diagnostic codes. The related diagnostic codes are:
CID 0670 - Torque Converter Pedal Position Switch
CID 0678 - Impeller Clutch Solenoid Valve
CID 0826 - Torque Converter Oil Temperature SensorTest Step 1. CHECK THE ON/OFF SWITCH
Table 1
Reduced Rimpull ON/OFF Switch    
Reduced Rimpull ON/OFF Switch    Terminal 2
Wire 164-WH
J1-6
Terminal 3
F741-WH
J1-34    
Switch Position    Switch Status    
OFF Position     Open (1)    
ON Position     Closed (2)    
( 1 ) No Continuity
( 2 ) Continuity
Disconnect the switch from the machine harness.
Connect the multimeter to contact 2 and contact 3.
Toggle the switch.
Measure the resistance between contact 2 and contact 3 of the switch.Expected Result:The resistance should be greater than 5000 ohms between contact 2 and contact 3 of the switch in the OFF position. The resistance should be less than 5 ohms between contact 2 and contact 3 of the switch in the ON position.Results:
OK - The resistance should be greater than 5000 ohms between contact 2 and contact 3 of the switch in the OFF position. The resistance should be less than 5 ohms between contact 2 and contact 3 of the switch in the ON position. Proceed to Test Step 2.
NOT OK - The resistance is not correct. The switch has failed.Repair: Replace the reduced rimpull ON/OFF switch. Stop.Test Step 2. CHECK THE SELECT SWITCH
Illustration 2 g01080084
Table 2
Reduced Rimpull Select Switch    
Reduced Rimpull Select Switch    Terminal 2
Wire E989-WH
J2-10
Terminal 3
E988-PU
J2-6
Terminal 1
202-BK
Frame Ground    
Switch Position     Switch Status    
Position A     OFF (1)    
Position B     Contact 1 and 2 (2)    
Position C     Contact 1 and 3 (2)    
Position D     Contact 1, 2 and 3 (2)    
( 1 ) No Continuity
( 2 ) Continuity
Place the switch in the B position.
Measure the resistance between contact 1 and contact 2.
Place the switch in the C position.
Measure the resistance between contact 1 and contact 3.
Place the switch in the D position.
Measure the resistance between contact 1 and contact 2. Measure the resistance between contact 1 and contact 3. Expected Result:The measurements agree with table 2.Results:
OK - The measurements agree with table 2. Proceed to Test Step 3.
NOT OK - The resistance is not correct with one or more of the measurements. The switch has failed.Repair: Replace the reduced rimpull switch. Stop.Test Step 3. CHECK THE GROUND CIRCUIT AT THE SWITCH
Turn the key start switch to the OFF position.
Measure the resistance between contact 1 (wire 202-BK) at the switch and frame ground.Expected Result:The resistance should be less than 5 ohms.Results:
OK - The resistance is less than 5 ohms. Proceed to Test Step 4.
NOT OK - The resistance is greater than 5 ohms. The ground circuit has failed.Repair: Repair the machine harness or replace the machine
Parts plate Caterpillar catalog:
3035644
PLATE AS
Caterpillar
Caterpillar
3035520
PLATE-LFT CAP.
Caterpillar
Caterpillar
3035390
PLATE
Caterpillar
Caterpillar
3035327
PLATE
Caterpillar
Caterpillar
3035254
PLATE
Caterpillar
Caterpillar
3035252
PLATE
Caterpillar
Caterpillar
3038201
PLATE AS
Caterpillar
Caterpillar
3038199
PLATE AS
Caterpillar
Caterpillar
3038198
PLATE AS
Caterpillar
Caterpillar
3035697
PLATE
Caterpillar
Caterpillar
3035694
PLATE
Caterpillar
Caterpillar
3035689
PLATE AS
Caterpillar
Caterpillar