Table 1
Diagnostic Trouble Codes That Cause the ARD to Be Disabled    
J1939 Code    Code Description    Comments    
3703-31     Particulate Trap Active Regeneration Inhibited Due to Inhibit Switch     The regeneration system is disabled by the "ARD Disable" switch.    
3712-15     DPF Active Regeneration Inhibited Due to System Fault Active : High - least severe (1)     The diesel particulate filter is not able to perform an active regeneration due to an active fault in the system.    
3716-15     DPF Active Regeneration Inhibited Due to Engine Not Warmed Up : High - least severe (1)     The diesel particulate filter is not able to perform an active regeneration because the exhaust gas temperature is too low.    
3750-15     DPF #1 Conditions Not Met for Active Regeneration : High - least severe (1)     The diesel particulate filter is not able to perform an active regeneration as one of the current engine pressures or temperatures is too high.    
3750-31     Diesel Particulate Filter 1 Conditions Not Met for Active Regeneration     The diesel particulate filter is not able to perform an active regeneration at the current engine operating conditions.    
Check for Diagnostic Codes that are Active
Connect the electronic service tool to the diagnostic connector.
Turn the keyswitch to the On position.
Monitor the active diagnostic code screen on the electronic service tool. Check and record any diagnostic codes that are active or logged. Look for the following diagnostic codes:
3703-31
3712-15
3716-15
3750-15
3750-31Note: Wait at least 30 seconds in order for the diagnostic codes to become active.
Remove the electrical power from the Electronic Control Module (ECM).
If a 3703-31 diagnostic code is present, proceed to Step 2.
If a 3712-15 diagnostic code is present, proceed to Step 3.
If a 3716-15 diagnostic code is present, proceed to Step 4.
If a 3750-15 or 3750-31 diagnostic code is present, proceed to Step 5.
A 3703-31 Diagnostic Code is Present.
The operator has disabled the regeneration system by moving the "ARD Disable" switch to the Stop position. Move the "ARD Disable" switch to the Start position in order to perform a regeneration.
Refer to the Operation and Maintenance Manual, "Monitoring System (Aftertreatment Regeneration Device)" for the correct operation of the regeneration system.
Return the unit to service.
A 3712-15 Diagnostic Code is Present.
Establish communication between the electronic service tool and the engine ECM.
Check for active faults related to the ARD combustion air system, ARD fuel system, or ARD ignition system.
Troubleshoot all active faults related to the ARD combustion air system, ARD fuel system, or ARD ignition system.
Clear any logged codes after correcting the faults.
Perform a DPF regeneration.
A 3716-15 Diagnostic Code is Present.
Raise the coolant temperature above 40° C (104° F ) and the Diesel Particulate Filter inlet temperature above 50° C (122° F). If the ambient temperature is −15° C (5° F) or below, the coolant temperature must be above 60° C (140° F) for an active regeneration to begin.
A 3750-15 or 3750-31 Diagnostic Code is Present.
The operator did not allow enough time at a suitable engine speed
Parts plate Caterpillar catalog:
3155173
PLATE
Caterpillar
Caterpillar
3155048
PLATE-WEAR
Caterpillar
Caterpillar
3155047
PLATE-WEAR
Caterpillar
Caterpillar
3154629
PLATE
Caterpillar
Caterpillar
3154604
PLATE-CAP
Caterpillar
Caterpillar
3154551
PLATE
Caterpillar
Caterpillar
3157092
PLATE AS
Caterpillar
Caterpillar
3156433
PLATE
Caterpillar
Caterpillar
3156220
PLATE GP-
Caterpillar
Caterpillar
3156053
PLATE-WEAR
Caterpillar
Caterpillar
3156044
PLATE-HOOK
Caterpillar
Caterpillar
3155793
PLATE
Caterpillar
Caterpillar