3449964 PLATE-LH Caterpillar parts
Rating:
Alternative (cross code) number:
CA3449964
344-9964
3449964
CA3449964
344-9964
3449964
Weight: 53 pounds 24 kg.
Information:
Normal Mode
The AccuGrade system automatically operates in normal mode when you start up the display. In order to start the display, turn the key start switch to the ON position. Press the power key.By default, the following soft keys are available when the display is in normal mode.
Bucket Tip focus ("Bucket Tip: Left or Bucket Tip: Center or Bucket Tip: Right")
GPSYou can also use the "Setup Menu – Configuration" screen in order to perform the following when you are in "Normal Mode - Setup Menu - Configuration" mode.Note: The list of options will very depending on the machine settings that have been chosen, that is, "Dual GPS", "Single GPS", "Single UTS", "Depth", and "Slope".
Select Design
GPS Accuracy
Vertical Setup
Lightbar Scales
Display and Lightbar Brightness
Beeper
Restore Settings
DiagnosticsService Mode
If you lack experience with the AccuGrade system, use extreme care when you are in service mode so that you do not accidentally change the AccuGrade system settings.
Configuration mode allows you to have access to all available options that the AccuGrade system offers.Use service mode in order to change the settings that affect the operation of the AccuGrade system.In order to turn on service mode, turn off the display if the display is ON. Press and hold down the "OK" key as you press the power key. Make sure that you hold down the "OK" key until the display shows the opening screen.In order to turn off service mode, turn off the display.Use the "Service" mode "Setup Menu - Configuration" screen in order to perform the following:
Select Design
Select Bucket
GPS Accuracy
Vertical Setup
Lightbar Scales
Display and Lightbar Brightness
Map Recording
Avoidance Zones
Text Items
Beeper
Save Settings
Restore Settings
GPS Receiver Configuration
Select Radio Band
DiagnosticsUse the "Service" mode "Setup Menu - Installation" screen in order to perform the following:
Machine Settings
Units
Machine Dimensions
GPS Option Keys
Machine Radio Configuration
Lightbar Connections
Calibrate Sensors
Arm Sensor Connections
Wireless Communication Support
Production Reporting
Upgrade Firmware
Operator ConfigurationTurn the display off in order to exit serivce mode after editing the settings or performing tests on the GPS receiver. This ensures that inexperienced users will not inadvertently change the settings of the AccuGrade system.
The AccuGrade system automatically operates in normal mode when you start up the display. In order to start the display, turn the key start switch to the ON position. Press the power key.By default, the following soft keys are available when the display is in normal mode.
Bucket Tip focus ("Bucket Tip: Left or Bucket Tip: Center or Bucket Tip: Right")
GPSYou can also use the "Setup Menu – Configuration" screen in order to perform the following when you are in "Normal Mode - Setup Menu - Configuration" mode.Note: The list of options will very depending on the machine settings that have been chosen, that is, "Dual GPS", "Single GPS", "Single UTS", "Depth", and "Slope".
Select Design
GPS Accuracy
Vertical Setup
Lightbar Scales
Display and Lightbar Brightness
Beeper
Restore Settings
DiagnosticsService Mode
If you lack experience with the AccuGrade system, use extreme care when you are in service mode so that you do not accidentally change the AccuGrade system settings.
Configuration mode allows you to have access to all available options that the AccuGrade system offers.Use service mode in order to change the settings that affect the operation of the AccuGrade system.In order to turn on service mode, turn off the display if the display is ON. Press and hold down the "OK" key as you press the power key. Make sure that you hold down the "OK" key until the display shows the opening screen.In order to turn off service mode, turn off the display.Use the "Service" mode "Setup Menu - Configuration" screen in order to perform the following:
Select Design
Select Bucket
GPS Accuracy
Vertical Setup
Lightbar Scales
Display and Lightbar Brightness
Map Recording
Avoidance Zones
Text Items
Beeper
Save Settings
Restore Settings
GPS Receiver Configuration
Select Radio Band
DiagnosticsUse the "Service" mode "Setup Menu - Installation" screen in order to perform the following:
Machine Settings
Units
Machine Dimensions
GPS Option Keys
Machine Radio Configuration
Lightbar Connections
Calibrate Sensors
Arm Sensor Connections
Wireless Communication Support
Production Reporting
Upgrade Firmware
Operator ConfigurationTurn the display off in order to exit serivce mode after editing the settings or performing tests on the GPS receiver. This ensures that inexperienced users will not inadvertently change the settings of the AccuGrade system.
Parts plate Caterpillar catalog:
3449963
PLATE-RH
Caterpillar
Caterpillar
3449962
PLATE
Caterpillar
Caterpillar
3449961
PLATE-TEMPLATE
Caterpillar
Caterpillar
3449926
PLATE AS-RH
Caterpillar
Caterpillar
3449902
PLATE AS-RH
Caterpillar
Caterpillar
3449830
PLATE AS
Caterpillar
Caterpillar
3450009
PLATE AS-RH
Caterpillar
Caterpillar
3450057
PLATE-TEMPLATE
Caterpillar
Caterpillar
3450058
PLATE-RH
Caterpillar
Caterpillar
3450059
PLATE-LH
Caterpillar
Caterpillar
3450106
PLATE AS.
Caterpillar
Caterpillar
3450109
PLATE
Caterpillar
Caterpillar