4548321 PLATE & FILM GP Caterpillar parts
Rating:
Alternative (cross code) number:
CA4548321
454-8321
4548321
CA4548321
454-8321
4548321
Information:
T2a - Undesired Electrical System Current - Test (For Machines Equipped With a Main Disconnect Switch)
Turn off all of the accessories. Turn the keyswitch to the OFF position.
Clamp a 9U-5795 Current Probe or 225-8266 Ammeter Tool Gp around the main ground cable. Clamp the tool with the positive side away from the battery. Reset the probe (zero) before you clamp the probe around the wire. Read the current. Expected Result: The current is below 2 A.Results:
YES - The current is below 2 A. Continue to Step 3.
NO - The current is above 2 A. There is a current draw in the system. Go to Testing and Adjusting, "T5 Alternator Current - Test"
Turn the disconnect switch to the ON position. Connect a multimeter across the disconnect switch terminals. Connect the red lead to the terminal on the frame side. Connect the black lead to the terminal on the battery side. Use the 10A connections in order to avoid damage.
Turn off the disconnect switch and read the current. Expected Result: The current is below .050 amperes (50 mA).Note: The standard acceptable current draw is 50 mA. A current draw above 50 mA usually indicates a problem. However, some large machines with multiple electronic control modules have a higher acceptable limit. Contact a Caterpillar dealer
Turn off all of the accessories. Turn the keyswitch to the OFF position.
Clamp a 9U-5795 Current Probe or 225-8266 Ammeter Tool Gp around the main ground cable. Clamp the tool with the positive side away from the battery. Reset the probe (zero) before you clamp the probe around the wire. Read the current. Expected Result: The current is below 2 A.Results:
YES - The current is below 2 A. Continue to Step 3.
NO - The current is above 2 A. There is a current draw in the system. Go to Testing and Adjusting, "T5 Alternator Current - Test"
Turn the disconnect switch to the ON position. Connect a multimeter across the disconnect switch terminals. Connect the red lead to the terminal on the frame side. Connect the black lead to the terminal on the battery side. Use the 10A connections in order to avoid damage.
Turn off the disconnect switch and read the current. Expected Result: The current is below .050 amperes (50 mA).Note: The standard acceptable current draw is 50 mA. A current draw above 50 mA usually indicates a problem. However, some large machines with multiple electronic control modules have a higher acceptable limit. Contact a Caterpillar dealer
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts plate Caterpillar catalog:
4547209
PLATE AS
Caterpillar
Caterpillar
4547208
PLATE AS
Caterpillar
Caterpillar
4545687
PLATE & FILM GP
Caterpillar
Caterpillar
4544230
PLATE AS
Caterpillar
Caterpillar
4538159
PLATE-WEAR
Caterpillar
Caterpillar
4538158
PLATE-WEAR
Caterpillar
Caterpillar
4562489
PLATE
Caterpillar
Caterpillar
4559045
PLATE AS
Caterpillar
Caterpillar
4555525
PLATE
Caterpillar
Caterpillar
4552948
PLATE
Caterpillar
Caterpillar
4552947
PLATE
Caterpillar
Caterpillar
4551587
PLATE-END
Caterpillar
Caterpillar