Illustration 1 g01256673
Connections of the blade right lower solenoidThis diagnostic code is associated with the blade right lower solenoid. The FMI 06 means that the ECM has determined that the current for the solenoid is above normal. The ECM uses a PWM signal in order to control the solenoid. The ECM will vary the electrical current of the PWM signal in order to provide proportional control of the solenoid.Some possible causes of this diagnostic code are listed:
The energize circuit of the solenoid is shorted to ground.
The solenoid has failed.
The ECM has failed. This condition is unlikely. Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Inspect the connections for the following:
Connections are clean.
Connections are secure.
Connections are in good condition.If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Note: The resistance of the solenoid coil should be 8.7 .4 ohms at 25 °C (77.0 °F).Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:The active CID 2163 FMI 06 diagnostic code changes to CID 2163 FMI 05 diagnostic code when the solenoid is disconnected.Results:
YES - The active CID 2163 FMI 06 diagnostic code changes to a CID 2163 FMI 05 diagnostic code when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid.STOP
NO - The CID 2163 FMI 06 remains active when the solenoid is disconnected. The solenoid is not causing the problem. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the ECM connectors J1 and J2 from the ECM.
At the ECM connectors of the machine harness, measure the resistance from the signal contact J1-62 (wire R903-OR) to frame ground. Measure the resistance from the signal contact J1-62 (wire R903-OR) to all of the other contacts that are used in the ECM connectors.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - One or more of the resistance measurements is less than 5000 ohms. There is a short in the machine harness. The short is between wire R903-OR and the circuit with the low resistance measurement. Repair: Repair the machine harness or replace the machine harness. STOPTest Step
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts plate Caterpillar catalog:
4887914
PLATE AS-WEAR
Caterpillar
Caterpillar
4887912
PLATE AS-WEAR
Caterpillar
Caterpillar
4885222
PLATE AS
Caterpillar
Caterpillar
4884031
PLATE AS
Caterpillar
Caterpillar
4883371
PLATE
Caterpillar
Caterpillar
4883370
PLATE
Caterpillar
Caterpillar
4892162
PLATE-WEAR
Caterpillar
Caterpillar
4892161
PLATE-WEAR
Caterpillar
Caterpillar
4892160
PLATE-WEAR
Caterpillar
Caterpillar
4892138
PLATE AS
Caterpillar
Caterpillar
4892128
PLATE
Caterpillar
Caterpillar
4892084
PLATE
Caterpillar
Caterpillar