AVSPARE.COM
parts catalog

PLATE 5288795 - Caterpillar


5288795 PLATE Caterpillar parts
Rating:
26
Alternative (cross code) number:
CA5288795
528-8795
5288795
Caterpillar 5288795 PLATE
Weight: 8 pounds 3 kg.

Buy PLATE 5288795 Caterpillar genuine, new aftermarket tractor parts with delivery

Number on catalog scheme: 28
  For full view, you need register

Information:


Table 1
J1939 Code and Description Comments
105-3
Engine Intake Manifold #1 Temperature : Voltage Above Normal The Electronic Control Module (ECM) detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
105-4
Engine Intake Manifold #1 Temperature : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
110-3
Engine Coolant Temperature : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
Note: For a 110-3 code, start the engine and let the engine idle for 7 minutes. The engine must be running for at least 7 minutes in order for the diagnostic to run.
110-4
Engine Coolant Temperature : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
171-3
Ambient Air Temperature : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
171-4
Ambient Air Temperature : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
175-3
Engine Oil Temperature 1 : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
175-4
Engine Oil Temperature 1 : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
1172-3
Engine Turbocharger #1 Compressor Inlet Temperature : Voltage Above Normal
1172-4
Engine Turbocharger #1 Compressor Inlet Temperature : Voltage Below Normal The sensor signal for the passive sensor is routed from the ECM to terminal 1 of the sensor connector. The sensor return for the passive sensors is routed from the ECM to terminal 2 of the sensor connector.When the ECM detects voltage that is above a threshold on the signal wire, the ECM activates a high voltage -3 diagnostic code. When the ECM detects voltage that is below a threshold on the signal wire, the ECM activates a low voltage -4 diagnostic code.Note: There may be a delay of 30 seconds or more in order for Cat® Electronic Technician (ET) to display an active diagnostic code. When you check for a diagnostic code, be sure to wait at least 30 seconds.
Illustration 1 g06138503
For the complete circuit details, refer to the full schematic.
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -3 code is

Caterpillar parts catalog:

Caterpillar parts catalog
963K Track-Type Loader YDR00001-UP (MACHINE) POWERED BY C7.1 Engine
963K TRACK-TYPE LOADER LBL00001-UP (MACHINE) POWERED BY C7.1 Engine


Parts plate Caterpillar catalog:

Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.